Fluke 52 II Wired Digital Thermometer, Type J, K, Type T, Type E Probe, 2 Input(s), 1767 °C Max, ±0.05 % + 0.3°C
- RS Stock No.:
- 353-4455
- Distrelec Article No.:
- 176-66-431
- Mfr. Part No.:
- FLUKE-52-2
- Manufacturer:
- Fluke
This image is representative of the product range
Alternative
This product is not currently available. Here is our alternative recommendation.
Each
PHP9,447.65
(exc. VAT)
PHP10,581.37
(inc. VAT)
- RS Stock No.:
- 353-4455
- Distrelec Article No.:
- 176-66-431
- Mfr. Part No.:
- FLUKE-52-2
- Manufacturer:
- Fluke
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Maximum Temperature Measurement | 1767°C | |
| Product Type | Digital Thermometer | |
| Model Number | 52 II | |
| Probe Type | Type J, K, Type T, Type E | |
| Thermometer Type | Wired | |
| Accuracy | ±0.05 % + 0.3°C | |
| Number of Temperature Inputs | 2 | |
| Data Storage | Yes | |
| Power Source | Battery | |
| Battery Life | 1000h | |
| Standards/Approvals | CE, CSA, NIST-175, TUV | |
| Hazardous Area Certification | No | |
| Length | 173mm | |
| Height | 38mm | |
| Width | 86mm | |
| Weight | 400g | |
| Temperature Scale | F, Fahrenheit, °C | |
| Minimum/Maximum Recordings | Yes | |
| Battery Type | 3 x AA | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Maximum Temperature Measurement 1767°C | ||
Product Type Digital Thermometer | ||
Model Number 52 II | ||
Probe Type Type J, K, Type T, Type E | ||
Thermometer Type Wired | ||
Accuracy ±0.05 % + 0.3°C | ||
Number of Temperature Inputs 2 | ||
Data Storage Yes | ||
Power Source Battery | ||
Battery Life 1000h | ||
Standards/Approvals CE, CSA, NIST-175, TUV | ||
Hazardous Area Certification No | ||
Length 173mm | ||
Height 38mm | ||
Width 86mm | ||
Weight 400g | ||
Temperature Scale F, Fahrenheit, °C | ||
Minimum/Maximum Recordings Yes | ||
Battery Type 3 x AA | ||
RoHS Status: Exempt
- COO (Country of Origin):
- CN
Fluke Digital Thermometer, 1372°C Maximum Temperature Measurement, ±0.05%+0.3°C Accuracy - FLUKE-52-2
Features & Benefits
• Dual-input display shows T1, T2 and T1–T2 for comparative checks
• Supports Type J, K, T, E thermocouples for versatile sensor selection
• Measures up to 1372°C to cover high-temperature tasks
• Typical 1000 h battery life from three standard AA cells for long shifts
• Electronic offset function compensates for thermocouple errors in situ
**Applications**
• Ideal for HVAC diagnostics and balancing tasks
• Used for food safety temperature verification in production lines
• Can be used for motor and bearing temperature monitoring during maintenance
• Used with insulated pipes and wiring inspections in electrical systems
Which thermocouple types can be connected simultaneously?
How does the instrument help time-stamping of events?
What environmental conditions will it operate in reliably?
How is calibration managed and what service type applies?
What protections and approvals relate to safety and durability?
Related links
- Fluke 54 II B Wired Digital Thermometer K Type J Type S 2 Input(s), 1767 °C
- RS PRO 1314 Wired Digital Thermometer K Type S Type R 2 Input(s)
- RS PRO 1315 Wired Digital Thermometer Type T K Type S 1 Input(s)
- Fluke 51 II Wired Digital Thermometer K Type E Probe 1372 °C Max, ±0.3 K Accuracy
- RS PRO 1313 Wired Digital Thermometer Type R Type J K 1 Input(s)
- Fluke 53 II Digital Digital Thermometer Type J Type N Type T 1 Input(s), 1767 °C
- RS PRO RS55-II Wired Digital Thermometer K Probe 1372 °C Max, ±0.7 K Accuracy
- RS PRO RS53-II Wired Digital Thermometer K Probe 1372 °C Max, ±0.1 % Accuracy