Fluke 718 -850 mbar to 7 bar Pressure Calibrator
- RS Stock No.:
- 351-2815
- Mfr. Part No.:
- FLUKE-718 100US/APAC
- Manufacturer:
- Fluke
- RS Stock No.:
- 351-2815
- Mfr. Part No.:
- FLUKE-718 100US/APAC
- Manufacturer:
- Fluke
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Maximum Pressure Measurement | 7bar | |
| Battery Type | Alkaline | |
| Product Type | Pressure Calibrator | |
| Minimum Pressure Measurement | -850mbar | |
| Accuracy | ±0.015 % | |
| Resolution | 0.1 mbar | |
| Model Number | 718 | |
| Data Logging | No | |
| Current Loop Measurement | Yes | |
| Display Type | LCD | |
| Power Source | Battery | |
| Weight | 992g | |
| Minimum Operating Temperature | -10°C | |
| Maximum Operating Temperature | 55°C | |
| Battery Life | 20h | |
| Standards/Approvals | No | |
| Width | 94mm | |
| Length | 216mm | |
| Height | 66mm | |
| Hazardous Area Certification | No | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Maximum Pressure Measurement 7bar | ||
Battery Type Alkaline | ||
Product Type Pressure Calibrator | ||
Minimum Pressure Measurement -850mbar | ||
Accuracy ±0.015 % | ||
Resolution 0.1 mbar | ||
Model Number 718 | ||
Data Logging No | ||
Current Loop Measurement Yes | ||
Display Type LCD | ||
Power Source Battery | ||
Weight 992g | ||
Minimum Operating Temperature -10°C | ||
Maximum Operating Temperature 55°C | ||
Battery Life 20h | ||
Standards/Approvals No | ||
Width 94mm | ||
Length 216mm | ||
Height 66mm | ||
Hazardous Area Certification No | ||
RoHS Status: Exempt
- COO (Country of Origin):
- CN
Fluke Pressure Calibrator, 7 Bar Maximum Pressure Measurement, ±0.015 % Accuracy - FLUKE-718 100
This pressure calibrator is a compact, battery-powered handheld instrument designed to generate and measure pneumatic pressure and to verify current loop signals for industrial calibration of transmitters, gauges and switches. It operates in field conditions between -10°C and 55°C and displays simultaneous pressure and current readings on an LCD for straightforward on-site diagnostics.
Features and Benefits:
• ±0.015% mA accuracy delivers precise current measurement
• 0.1 mbar resolution enables fine pressure discrimination
• -850 mbar to 7 bar range supports negative and positive pressures
• Battery powered with 20 h life reduces interruption in field work
• Current loop capability measures and drives 4-20 mA signals
• Lightweight 992 g construction improves portability during tasks
• 0.1 mbar resolution enables fine pressure discrimination
• -850 mbar to 7 bar range supports negative and positive pressures
• Battery powered with 20 h life reduces interruption in field work
• Current loop capability measures and drives 4-20 mA signals
• Lightweight 992 g construction improves portability during tasks
Applications
• Suitable for calibrating pressure transmitters and gauges on-site
• Used for testing pressure switches in process control systems
• Ideal for loop validation and 4-20 mA instrument checks
• Can be used for service work where Compact tools are required
• Used with non‑corrosive gases during routine maintenance
• Used for testing pressure switches in process control systems
• Ideal for loop validation and 4-20 mA instrument checks
• Can be used for service work where Compact tools are required
• Used with non‑corrosive gases during routine maintenance
What type of batteries does it use and how are they installed?
It uses alkaline 9 V batteries (ANSI/NEDA 1604A or IEC 6LR61) and requires two cells installed in the battery compartment.
How does the pump handle exposure to process fluids?
The pump includes protective check valves and a serviceable valve assembly that can be cleaned in the field using isopropyl alcohol and Basic tools.
What display information is available simultaneously during calibration?
The LCD shows five‑digit pressure and current readings at the same time for concurrent measurement review.
How does the unit perform switch testing?
A dedicated switch test function captures trip and reset points, aiding Faster and more accurate pressure switch assessments.
What environmental stresses can the instrument withstand during transport?
It tolerates a 1 m drop test and random vibration at 2 g across 5 Hz-500 Hz frequencies.
Supplied with
protective yellow holster, test lead set, crocodile clips, 9V alkaline battery (fitted)
Related links
- Fluke 718 -850 mbar to 20 bar Pressure Calibrator
- Fluke 719 -850 mbar to 8 bar Pressure Calibrator
- Fluke 719 -850 mbar to 2.4 bar Pressure Calibrator
- Fluke 717 -850 mbar to 7 bar Pressure Calibrator
- Fluke 717 -850 mbar to 20 bar Pressure Calibrator
- Fluke 719PRO -0.8 bar to 10 bar Pressure Calibrator
- Fluke 719PRO -0.8 bar to 20 bar Pressure Calibrator