ABB GJL121 Contactor, 48V ac Coil, 3-Pole, 20 A, 4 kW 48V ac, 3 NO/1 NC, 690V
- RS Stock No.:
- 253-4727
- Mfr. Part No.:
- GJL1211001R0013
- Manufacturer:
- ABB
This image is representative of the product range
Subtotal (1 pack of 10 units)*
PHP25,445.70
(exc. VAT)
PHP28,499.20
(inc. VAT)
FREE delivery for orders over ₱3,000.00
Stocked by manufacturer
- Ready to ship from June 11, 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per Unit | Per Pack* |
|---|---|---|
| 10 + | PHP2,544.57 | PHP25,445.70 |
*price indicative
- RS Stock No.:
- 253-4727
- Mfr. Part No.:
- GJL1211001R0013
- Manufacturer:
- ABB
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | ABB | |
| Product Type | Contactor | |
| Coil Voltage | 48V ac | |
| Number of Poles | 3 | |
| Contact Voltage | 690V | |
| Contact Current | 20A | |
| Power Rating | 4kW | |
| Series | GJL121 | |
| Mount Type | DIN Rail | |
| Function | Control Unit | |
| Normal State Configuration | 3 NO/1 NC | |
| Number of Auxiliary Contacts | 1 | |
| Auxiliary Contact Configuration | 1 NC | |
| Terminal Type | Screw | |
| Operational Current Ie | 16A | |
| Control Circuit Voltage Uc | 48V ac | |
| Minimum Operating Temperature | -25°C | |
| Contactor Application | Control Unit | |
| Maximum Operating Temperature | 55°C | |
| Width | 52.5mm | |
| Standards/Approvals | IEC/EN 60947-1 | |
| Length | 46.7mm | |
| Depth | 46.7mm | |
| Pole and Throw Configuration | 3P | |
| Select all | ||
|---|---|---|
Brand ABB | ||
Product Type Contactor | ||
Coil Voltage 48V ac | ||
Number of Poles 3 | ||
Contact Voltage 690V | ||
Contact Current 20A | ||
Power Rating 4kW | ||
Series GJL121 | ||
Mount Type DIN Rail | ||
Function Control Unit | ||
Normal State Configuration 3 NO/1 NC | ||
Number of Auxiliary Contacts 1 | ||
Auxiliary Contact Configuration 1 NC | ||
Terminal Type Screw | ||
Operational Current Ie 16A | ||
Control Circuit Voltage Uc 48V ac | ||
Minimum Operating Temperature -25°C | ||
Contactor Application Control Unit | ||
Maximum Operating Temperature 55°C | ||
Width 52.5mm | ||
Standards/Approvals IEC/EN 60947-1 | ||
Length 46.7mm | ||
Depth 46.7mm | ||
Pole and Throw Configuration 3P | ||
- COO (Country of Origin):
- DE
ABB GJL121 Series Contactor, 48V AC Coil Voltage, 20A Current Rating - GJL1211001R0013
This contactor is a robust control unit designed to manage electrical circuits with efficiency and precision. With a Compact design that measures 46.7mm in length, 52.5mm in width, and 46.7mm in depth, it features a 3-pole configuration, making it Ideal for various electrical applications. It operates effectively within a temperature range of -25 to +55°C and at a Coil voltage of 48 V AC, this unit provides reliable performance with a contact voltage rating of 690V and a contact current rating of 20 A.
Features & Benefits
• Provides efficient control for electrical circuits with 3 pole configurations
• Supports a maximum power rating of 4 kW for various applications
• Features a screw Terminal design for secure connections
• Offers one auxiliary contact with a normally closed configuration
• Designed for DIN rail mounting to optimise space in control panels
• Supports a maximum power rating of 4 kW for various applications
• Features a screw Terminal design for secure connections
• Offers one auxiliary contact with a normally closed configuration
• Designed for DIN rail mounting to optimise space in control panels
Applications
• Used for controlling motors in industrial automation systems
• Functions in lighting control circuits to enhance efficiency
• Utilised in HVAC systems to manage operational functionality
• Applicable in machinery control for seamless operational management
• Functions in lighting control circuits to enhance efficiency
• Utilised in HVAC systems to manage operational functionality
• Applicable in machinery control for seamless operational management
What is the significance of the Coil voltage for this device?
The Coil voltage of 48 V AC is Crucial as it ensures proper activation of the contactor while maintaining safe operation within its electrical circuits, preventing potential overload.
How does the auxiliary contact contribute to the functionality of this control unit?
The single normally closed auxiliary contact allows for interlocking or feedback circuits, enabling better control and monitoring of associated devices in real-time applications.
What mounting options are available for convenient installation?
This unit is specifically designed for DIN rail mounting, which simplifies installation and configuration within existing electrical panels, ensuring a tidy and efficient setup.
What thermal limits should be considered when using this contactor?
It is important to operate this contactor within the specified temperature range of -25 to +55°Cto ensure optimal performance and longevity without risk of overheating.
Related links
- ABB GJL121 Contactor 3-Pole 4 kW 48V ac 690V
- ABB GJL121 Contactor 4-Pole 4 kW 48V ac 690V
- ABB GJL121 Contactor 3-Pole 4 kW 48V 690V
- ABB GJL121 Contactor 4-Pole 4 kW 48V ac 690V
- ABB GJL121 Contactor 4-Pole 4 kW 48V ac 690V
- ABB GJL121 Contactor 3-Pole 4 kW 48V 690V dc
- ABB GJL121 Contactor 3-Pole 4 kW 48V 690V
- ABB GJL121 Contactor 415 V ac Coil 20 A 3 NO/1 NC, 690V
