ABB GJL121 Contactor, 48V Coil, 3-Pole, 20 A, 4 kW 48V, 3 NO/1 NC, 690V
- RS Stock No.:
- 253-4763
- Mfr. Part No.:
- GJL1213001R1016
- Manufacturer:
- ABB
Subtotal (1 pack of 10 units)*
PHP26,943.32
(exc. VAT)
PHP30,176.52
(inc. VAT)
FREE delivery for orders over ₱3,000.00
Stocked by manufacturer
- Ready to ship from May 29, 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per Unit | Per Pack* |
|---|---|---|
| 10 + | PHP2,694.332 | PHP26,943.32 |
*price indicative
- RS Stock No.:
- 253-4763
- Mfr. Part No.:
- GJL1213001R1016
- Manufacturer:
- ABB
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | ABB | |
| Coil Voltage | 48V | |
| Product Type | Contactor | |
| Number of Poles | 3 | |
| Contact Voltage | 690V | |
| Contact Current | 20A | |
| Power Rating | 4kW | |
| Series | GJL121 | |
| Mount Type | DIN Rail | |
| Function | Mini Contactor | |
| Normal State Configuration | 3 NO/1 NC | |
| Number of Auxiliary Contacts | 1 | |
| Terminal Type | Screw | |
| Contactor Application | Control Unit | |
| Control Circuit Voltage Uc | 48V | |
| Minimum Operating Temperature | -25°C | |
| Operational Current Ie | 20A | |
| Maximum Operating Temperature | 55°C | |
| Length | 46.7mm | |
| Standards/Approvals | IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1 | |
| Depth | 46.7mm | |
| Width | 53mm | |
| Pole and Throw Configuration | 3 | |
| Select all | ||
|---|---|---|
Brand ABB | ||
Coil Voltage 48V | ||
Product Type Contactor | ||
Number of Poles 3 | ||
Contact Voltage 690V | ||
Contact Current 20A | ||
Power Rating 4kW | ||
Series GJL121 | ||
Mount Type DIN Rail | ||
Function Mini Contactor | ||
Normal State Configuration 3 NO/1 NC | ||
Number of Auxiliary Contacts 1 | ||
Terminal Type Screw | ||
Contactor Application Control Unit | ||
Control Circuit Voltage Uc 48V | ||
Minimum Operating Temperature -25°C | ||
Operational Current Ie 20A | ||
Maximum Operating Temperature 55°C | ||
Length 46.7mm | ||
Standards/Approvals IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1 | ||
Depth 46.7mm | ||
Width 53mm | ||
Pole and Throw Configuration 3 | ||
- COO (Country of Origin):
- DE
ABB GJL121 Series Contactor, 20A Current Rating, 48V Control Circuit Voltage - GJL1213001R1016
This contactor is a Compact switching device designed for control and protection tasks in commercial electrical installations. It operates within low-voltage control circuits and is intended to handle switching of three-phase loads, providing a Compact solution for motor control and general-purpose switching in automated systems.
Features and Benefits:
• 48V Coil supports low-voltage control circuits for safer operation
• 3-pole switching delivers 3P distribution for three-phase loads
• 20A operational current enables switching of moderate power circuits
• 690V rated contact voltage allows use in higher-voltage systems
• 4kW power rating suits small motor-control applications
• Screw terminals provide secure, serviceable electrical connections
• 3-pole switching delivers 3P distribution for three-phase loads
• 20A operational current enables switching of moderate power circuits
• 690V rated contact voltage allows use in higher-voltage systems
• 4kW power rating suits small motor-control applications
• Screw terminals provide secure, serviceable electrical connections
Applications
• Suitable for controlling small three-phase motors up to 4kW
• Ideal for integration on DIN-rail distribution frames
• Used with wall-mounted panels in light-industrial installations
• Can be used for commercial switching of HVAC and pump systems
• Ideal for integration on DIN-rail distribution frames
• Used with wall-mounted panels in light-industrial installations
• Can be used for commercial switching of HVAC and pump systems
What auxiliary contact arrangement is available for control logic?
It includes a single auxiliary contact configured normally closed to support interlocks and signalling.
How does the device mount to control enclosures?
It can be fixed directly to standard DIN rail or attached to a panel wall for flexible installation.
What environmental temperature range can it tolerate during operation?
It is specified to operate reliably between -25°C and 55°C for typical commercial settings.
Which standards govern its safety and performance?
It is manufactured to meet IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1 and corresponding UL equivalents.
How many auxiliary contacts and poles are provided for control and power paths?
The unit provides one auxiliary contact and three power poles for simultaneous three-phase switching.
Related links
- ABB GJL121 Contactor 3-Pole 4 kW 48 V 690V
- ABB GJL121 Contactor 4-Pole 4 kW 48 V ac 690V
- ABB GJL121 Contactor 3-Pole 4 kW 48 V 690V
- ABB GJL121 Contactor 3-Pole 4 kW 48 V 690V dc
- ABB GJL121 Contactor 4-Pole 4 kW 48 V ac 690V
- ABB GJL121 Contactor 3-Pole 4 kW 48 V ac 690V
- ABB GJL121 Contactor 4-Pole 4 kW 48 V ac 690V
- ABB GJL121 Contactor 3-Pole 4 kW 24 V 690V