ABB GJL121 Contactor, 48V ac Coil, 4-Pole, 20 A, 4 kW 48V ac, 2 NO/2 NC, 690V
- RS Stock No.:
- 253-4782
- Mfr. Part No.:
- GJL1213501R1006
- Manufacturer:
- ABB
Subtotal (1 unit)*
PHP2,798.62
(exc. VAT)
PHP3,134.45
(inc. VAT)
FREE delivery for orders over ₱3,000.00
Temporarily out of stock
- Shipping from May 13, 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per Unit |
|---|---|
| 1 + | PHP2,798.62 |
*price indicative
- RS Stock No.:
- 253-4782
- Mfr. Part No.:
- GJL1213501R1006
- Manufacturer:
- ABB
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | ABB | |
| Product Type | Contactor | |
| Coil Voltage | 48V ac | |
| Number of Poles | 4 | |
| Contact Voltage | 690V | |
| Contact Current | 20A | |
| Power Rating | 4kW | |
| Series | GJL121 | |
| Mount Type | DIN Rail | |
| Function | Mini Contactor | |
| Normal State Configuration | 2 NO/2 NC | |
| Terminal Type | Screw | |
| Operational Current Ie | 20A | |
| Control Circuit Voltage Uc | 48V ac | |
| Minimum Operating Temperature | -20°C | |
| Contactor Application | Control Unit | |
| Maximum Operating Temperature | 55°C | |
| Width | 53mm | |
| Standards/Approvals | IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1 | |
| Length | 46.7mm | |
| Depth | 46.7mm | |
| Pole and Throw Configuration | 4 | |
| Select all | ||
|---|---|---|
Brand ABB | ||
Product Type Contactor | ||
Coil Voltage 48V ac | ||
Number of Poles 4 | ||
Contact Voltage 690V | ||
Contact Current 20A | ||
Power Rating 4kW | ||
Series GJL121 | ||
Mount Type DIN Rail | ||
Function Mini Contactor | ||
Normal State Configuration 2 NO/2 NC | ||
Terminal Type Screw | ||
Operational Current Ie 20A | ||
Control Circuit Voltage Uc 48V ac | ||
Minimum Operating Temperature -20°C | ||
Contactor Application Control Unit | ||
Maximum Operating Temperature 55°C | ||
Width 53mm | ||
Standards/Approvals IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1 | ||
Length 46.7mm | ||
Depth 46.7mm | ||
Pole and Throw Configuration 4 | ||
- COO (Country of Origin):
- DE
ABB GJL121 Series Contactor, 20A Contact Current, 48V AC Coil Voltage - GJL1213501R1006
This contactor is a Compact switching device designed for commercial electrical control systems, providing controlled switching of power circuits in automation and industrial settings. It operates with a 48V AC control circuit and is intended for installations where a small footprint and flexible mounting are required, such as DIN-rail or wall-mounted panels.
Features and Benefits:
• Four poles with 20A operational current for multi-phase switching
• Rated for up to 690V enabling high-voltage circuit use
• 4kW power handling for moderate motor and load control
• Screw Terminal connections for secure wiring termination
• Built to IEC/EN and UL contactor standards for industrial compatibility
• Ambient operation from -20°C to 55°C for varied site conditions
• Rated for up to 690V enabling high-voltage circuit use
• 4kW power handling for moderate motor and load control
• Screw Terminal connections for secure wiring termination
• Built to IEC/EN and UL contactor standards for industrial compatibility
• Ambient operation from -20°C to 55°C for varied site conditions
Applications
• Suitable for switching small three-phase motors in commercial settings
• Ideal for control panels requiring DIN-rail mounted components
• Used for replacing Compact contactors in service and maintenance tasks
• Can be used for auxiliary load switching in building management systems
• Ideal for control panels requiring DIN-rail mounted components
• Used for replacing Compact contactors in service and maintenance tasks
• Can be used for auxiliary load switching in building management systems
What mounting options are available for installation flexibility?
It can be fitted to standard DIN rails or fixed directly to a wall-mounted panel to suit panel layouts and retrofits.
How is the control circuit powered and interfaced?
The Coil accepts 48V AC control voltage, compatible with typical commercial control supplies and PLC outputs.
What Terminal type is provided for conductor connections?
Terminals use screw-type fastenings to ensure firm conductor clamping and straightforward onsite wiring.
How many poles and what contact configuration does it provide?
The device includes four switching poles and a normal-state arrangement comprising two normally open and two normally closed contacts.
What environmental limits should be observed during operation?
The unit is rated for continuous operation within a temperature range from -20°C up to 55°C, so installations should remain within these bounds.
Related links
- ABB GJL121 Contactor 4-Pole 4 kW 48 V ac 690V
- ABB GJL121 Contactor 3-Pole 4 kW 48 V ac 690V
- ABB GJL121 Contactor 4-Pole 4 kW 48 V ac 690V
- ABB GJL121 Contactor 3-Pole 4 kW 48 V 690V
- ABB GJL121 Contactor 3-Pole 4 kW 48 V 690V
- ABB GJL121 Contactor 3-Pole 4 kW 48 V 690V dc
- ABB GJL131 Contactor 4-Pole 5.5 kW 48 V ac 690V
- ABB GJL121 Contactor 4-Pole 4 kW 24 V ac 690V