Fluke 83V Handheld Digital Multimeter, True RMS, 10A ac Max, 10A dc Max, 1000V ac Max
- RS Stock No.:
- 481-4314
- Mfr. Part No.:
- FLUKE 83-5
- Manufacturer:
- Fluke
This image is representative of the product range
Alternative
This product is not currently available. Here is our alternative recommendation.
Each
PHP38,003.00
(exc. VAT)
PHP42,563.36
(inc. VAT)
- RS Stock No.:
- 481-4314
- Mfr. Part No.:
- FLUKE 83-5
- Manufacturer:
- Fluke
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Multimeter Type | Handheld | |
| Model Number p | 83V | |
| Functions Measured | AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode, Frequency, Resistance, Temperature | |
| Absolute Maximum AC Current Measurement | 10A ac | |
| Absolute Maximum AC Voltage Measurement | 1000V ac | |
| Absolute Maximum DC Current Measurement | 10A dc | |
| Absolute Maximum Resistance Measurement | 50MΩ | |
| Absolute Maximum DC Voltage Measurement | 1000V dc | |
| Absolute Maximum Temperature Measurement | +1090°C | |
| Absolute Maximum Capacitance Measurement | 9.999mF | |
| Maximum Frequency | 20kHz | |
| DC Current Measurement Resolution | 0.1µA dc | |
| AC Current Measurement Resolution | 0.1µA ac | |
| Resistance Measurement Resolution | 100mΩ | |
| DC Voltage Measurement Resolution | 0.1mV dc | |
| AC Voltage Measurement Resolution | 0.1mV ac | |
| Temperature Measurement Resolution | 0.1°C | |
| Capacitance Measurement Resolution | 10nF | |
| Safety Category Level | CAT III, CAT IV | |
| Best AC Current Accuracy | ±1.2% + 2 Digits | |
| Best Resistance Measurement Accuracy | ±1% + 3 Digits | |
| Length | 186mm | |
| Battery Type | 9V | |
| Safety Category Voltage | 664 V, 1000 V | |
| Best DC Current Accuracy | ±0.4% + 2 Digits | |
| Best DC Voltage Accuracy | ±0.1% + 1 Digit | |
| Maximum Operating Temperature | +55°C | |
| Width | 86mm | |
| Best Temperature Measurement Accuracy | ±1% + 1 °C | |
| Best AC Voltage Accuracy | ±1% + 4 Digits | |
| Best Capacitance Measurement Accuracy | ±1% + 2 Digits | |
| Minimum Operating Temperature | -20°C | |
| Height | 31mm | |
| Weight | 355g | |
| Dimensions | 186 x 86 x 31mm | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Multimeter Type Handheld | ||
Model Number p 83V | ||
Functions Measured AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode, Frequency, Resistance, Temperature | ||
Absolute Maximum AC Current Measurement 10A ac | ||
Absolute Maximum AC Voltage Measurement 1000V ac | ||
Absolute Maximum DC Current Measurement 10A dc | ||
Absolute Maximum Resistance Measurement 50MΩ | ||
Absolute Maximum DC Voltage Measurement 1000V dc | ||
Absolute Maximum Temperature Measurement +1090°C | ||
Absolute Maximum Capacitance Measurement 9.999mF | ||
Maximum Frequency 20kHz | ||
DC Current Measurement Resolution 0.1µA dc | ||
AC Current Measurement Resolution 0.1µA ac | ||
Resistance Measurement Resolution 100mΩ | ||
DC Voltage Measurement Resolution 0.1mV dc | ||
AC Voltage Measurement Resolution 0.1mV ac | ||
Temperature Measurement Resolution 0.1°C | ||
Capacitance Measurement Resolution 10nF | ||
Safety Category Level CAT III, CAT IV | ||
Best AC Current Accuracy ±1.2% + 2 Digits | ||
Best Resistance Measurement Accuracy ±1% + 3 Digits | ||
Length 186mm | ||
Battery Type 9V | ||
Safety Category Voltage 664 V, 1000 V | ||
Best DC Current Accuracy ±0.4% + 2 Digits | ||
Best DC Voltage Accuracy ±0.1% + 1 Digit | ||
Maximum Operating Temperature +55°C | ||
Width 86mm | ||
Best Temperature Measurement Accuracy ±1% + 1 °C | ||
Best AC Voltage Accuracy ±1% + 4 Digits | ||
Best Capacitance Measurement Accuracy ±1% + 2 Digits | ||
Minimum Operating Temperature -20°C | ||
Height 31mm | ||
Weight 355g | ||
Dimensions 186 x 86 x 31mm | ||
RoHS Status: Not Applicable
Fluke Multimeter, 400h Battery Life, True RMS Capability - FLUKE 83V
Features & Benefits
• DC voltage accuracy ±0.1%rdg+1 digit for precise low‑level sensing
• AC current accuracy ±1.2%rdg+2 digits for reliable alternating current checks
• Frequency response up to 20kHz for high‑frequency signal diagnostics
• Temperature and capacitance functions extend troubleshooting to thermal and component testing
• Battery life 400h with alkaline cells reduces service disruptions
**Applications**
• Ideal for calibrating sensors and measuring low DC voltages in electronics labs
• Used for on‑site current checks and branch circuit verification in electrical maintenance
• Can be used for capacitor testing and component fault finding in mechanical control panels
• Used with temperature probes to troubleshoot thermal issues in assemblies
What display resolution and update behaviour can I expect for fast events?
How does the meter handle input protection and extreme inputs?
What environmental limits affect operation and storage?
How does the unit perform when measuring low currents and small conductance?
Note
Supplied with
Related links
- Gossen Metrawatt METRAHit PRO Handheld LCD Digital Multimeter 10A ac Max 1000V ac Max
- Fluke 83 Digital Digital Multimeter True RMS
- Fluke V3000 FC 3000 FC Handheld Digital Multimeter True RMS 1 kV ac
- Fluke 787B 787B Handheld Digital Multimeter True RMS 1 A, 1000 V
- Fluke 87V-MAX Digital Digital Multimeter True RMS 10 A, 1000 V
- Fluke 115 Digital Digital Multimeter True RMS
- RS PRO RS-946 Handheld Digital Multimeter True RMS, 600 V ac
- RS PRO S2 Handheld Digital Multimeter True RMS 400 mA dc, 1 kV ac

