Honeywell HAF Series Amplified Airflow Sensor for Dry Gas, 50cm³/min Max
- RS Stock No.:
- 821-3897
- Mfr. Part No.:
- HAFBLF0050CAAX5
- Manufacturer:
- Honeywell
Currently unavailable
We don't know if this item will be back in stock, RS intend to remove it from our range soon.
- RS Stock No.:
- 821-3897
- Mfr. Part No.:
- HAFBLF0050CAAX5
- Manufacturer:
- Honeywell
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Honeywell | |
| Product Type | Airflow Sensor | |
| Media Monitored | Dry Gas | |
| Device Type | Amplified | |
| Housing Material | Polymer | |
| Maximum Flow Rate | 50cm³/min | |
| Connection Type | Tubing | |
| Maximum Pressure | 25psi | |
| Maximum Supply Voltage | 5V dc | |
| Minimum Operating Temperature | -20°C | |
| Maximum Operating Temperature | 70°C | |
| Series | HAF | |
| Standards/Approvals | No | |
| Current Rating | 20mA | |
| Select all | ||
|---|---|---|
Brand Honeywell | ||
Product Type Airflow Sensor | ||
Media Monitored Dry Gas | ||
Device Type Amplified | ||
Housing Material Polymer | ||
Maximum Flow Rate 50cm³/min | ||
Connection Type Tubing | ||
Maximum Pressure 25psi | ||
Maximum Supply Voltage 5V dc | ||
Minimum Operating Temperature -20°C | ||
Maximum Operating Temperature 70°C | ||
Series HAF | ||
Standards/Approvals No | ||
Current Rating 20mA | ||
- COO (Country of Origin):
- CN
Honeywell Amplified Airflow Sensor, Dry Gas, 5V DC - HAF Series - HAFBLF0050CAAX5
Looking for a reliable high-response device for measuring the flow of air or other gas media? This amplified airflow sensor from Honeywell is designed with innovative Zephyr technology to provide highly accurate readings for mass flow of air and other non-corrosive gases. It's equipped with an advanced ASIC (application-specific integrated circuit) chip that produces a digital output at a response speed of 1ms. The sensor's compact nature means it takes up very little room on your PCB (printed circuit board), so you can use it in applications where space is limited. Its external housing is made from a high-quality polymer material that maintains resistance to chemicals and corrosion even under increased temperatures.
Features & Benefits
• Operating temperature range between -20°C and +70°C to cope with extreme conditions
• Low pressure drop reduces noise
• High stability improves overall performance and reduces errors from thermal effects
• Tubing connection style for easy integration
Applications
• HVAC (heating, ventilation, and air conditioning) filters
• Patient monitoring systems
How long can this digital airflow sensor last?
With regular maintenance, this airflow sensor will offer a long service life. The outer polymer material protects the component from damage from external sources, making it durable and suitable for use in harsh environments.
Honeywell Zephyr™ HAF Series – High Accuracy ±50 SCCM to ±750 SCCM
Honeywell Zephyr™ HAF Series sensors provide a digital interface for monitoring airflow over specified full-scale flow and compensated temperature ranges. The thermally isolated heater and temperature sensing elements help these sensors provide a fast response to air or gas flow.;Zephyr sensors are designed to measure mass flow of air and other non-corrosive gases. Standard flow ranges are available at ±50, ±100, ±200, ±400 or ±750 sccm. Custom flow ranges are also available. The sensors are fully calibrated and temperature compensated with an onboard Application Specific Integrated Circuit (ASIC).;The HAF Series is compensated over the temperature range of 0°C to 50°C and operates across a temperature range of -20°C to 70°C. The state-of-the-art ASIC-based compensation provides digital (I2C) outputs with a response time of 1 ms.;These sensors operate on the heat transfer principle to measure mass airflow. They consist of a microbridge Microelectronic and Microelectromechanical System (MEMS) with temperature-sensitive resistors deposited with thin films of platinum and silicon nitride. The MEMS sensing die is located in a precise and carefully designed airflow channel to provide repeatable response to flow.;Zephyr sensors provide the customer with enhanced reliability, high accuracy, repeatable measurements and the ability to customise sensor options to meet many specific application needs. The combination of rugged housings with a stable substrate makes these products robust. They are designed and manufactured according to ISO 9001 standards.
Features and Benefits
• Total error band as low as ±0.25%;• Fast response time;• Wide range of airflows;• Customisable flow ranges;• High sensitivity when flow is low;• Linear output provides more intuitive sensor signal;• High stability reduces errors due to thermal effects;• Low-pressure drop typically improves patient comfort in medical applications
Product Application Information
MEDICAL;• Anaesthesia delivery machines;• Ventricular assist devices (heart pumps);• Hospital diagnostics (spectrometry, gas chromatography);• Nebulisers;• Oxygen concentrators;• Patient monitoring systems (respiratory monitoring);• Sleep apnea machines;• Spirometers;• Ventilators;• Laparoscopy;INDUSTRIAL;• Air-to-fuel ratio;• Analytical instrumentation (spectrometry, chromatography);• Fuel cells;• Gas leak detection;• VAV system on HVAC systems;• Gas meters;• HVAC filters
Related links
- Honeywell AWM5000 Series Amplified Airflow Sensor for Dry Gas 10 L/min Max Calibrated
- Honeywell AWM5000 Series Amplified Airflow Sensor for Dry Gas 20 L/min Max Calibrated
- Honeywell HAF Series Digital Airflow Sensor for Air 1L/min Min, 10 L/min Max Calibrated
- Honeywell HAF Series Digital Airflow Sensor for Air 0L/min Min, 10 L/min Max Calibrated
- Honeywell HAF Series Digital Airflow Sensor for Air 0L/min Min, 15 L/min Max Calibrated
- Honeywell HAF Series Digital Airflow Sensor for Air 0L/min Min, 200 L/min Max Calibrated
- Honeywell HAF Series Digital Airflow Sensor for Air 100 L/min Max Calibrated
- Honeywell HAF Series Bi-Directional Flow Meter Airflow Sensor for Air 0.1 L/min Max Calibrated