SICK TR4 Safety Interlock Switch, RFID Actuator Included, Valox

Subtotal (1 unit)*

PHP14,633.48

(exc. VAT)

PHP16,389.50

(inc. VAT)

Add to Basket
Select or type quantity
In Stock
  • 14 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per Unit
1 +PHP14,633.48

*price indicative

RS Stock No.:
285-9055
Mfr. Part No.:
TR4-SAM02CB
Manufacturer:
SICK
Find similar products by selecting one or more attributes.
Select all

Brand

SICK

Product Type

Safety Interlock Switch

Lock Style

RFID

Actuator Included

Yes

Safety Contacts

2

Housing Material

Valox

Series

TR4

IP Rating

IP67, IP69K

Minimum Operating Temperature

-25°C

Contact DC Voltage

24V dc

Switch Contact Current

200mA

Contact AC Voltage

230V ac

Maximum Operating Temperature

70°C

Hazardous Area Certification

No

Length

67.1mm

Number of Head Directions

5

Width

67.1mm

Standards/Approvals

IEC 60529

COO (Country of Origin):
DO

SICK TR4 Series Safety Interlock Switch, IP67, 24V DC Supply Voltage - TR4-SAM02CB


This safety interlock switch is a non-contact RFID device designed for secure guarding in industrial automation. It provides dual safe outputs and self-monitoring semiconductor outputs suitable for connection to safety controllers, enabling safe series connection with diagnostic capability. The unit operates from a 24V DC supply and is suited to environments requiring high ingress protection.

Features and Benefits:


• SIL3 functional safety delivering high integrity
• Category 4 design ensuring Advanced fault tolerance
• PL e performance enabling demanding safety requirements
• Self-monitoring OSSD outputs supporting direct safety integration
• Low actuator coding minimising mechanical alignment needs

Applications


• Suitable for hazardous-area-free machine guarding installations
• Ideal for safety controller Flexi Loop diagnostic networks
• Used with automated access guards requiring non-contact sensing
• Can be used for production lines needing fast reset times
• Applicable in environments subject to vibration and shock

What connectors and cabling does it use?


It uses a 5-pin M12 plug with a 0.2m attached cable and supports extension runs up to 200m.

How does the device indicate status?


Built-in LEDs provide local status indication for operation and diagnostics.

What environmental protections are provided?


The enclosure meets IP67 and IP69K ratings and operates between -25°C and +70°C.

What electrical output and current limitations apply?


The self-monitoring semiconductor outputs deliver up to 200mA and are rated for 230V AC / 24V DC contact voltages.

How Durable is the switching mechanism?


The device is specified for 10x10^6 switching cycles and resists vibration and shock in accordance with relevant test standards.