SICK i110 Safety Switch, Power, Die Cast Zinc

Subtotal (1 unit)*

PHP9,253.94

(exc. VAT)

PHP10,364.41

(inc. VAT)

Add to Basket
Select or type quantity
Stocked by manufacturer
  • Ready to ship from December 04, 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per Unit
1 +PHP9,253.94

*price indicative

RS Stock No.:
285-1821
Mfr. Part No.:
i110-HA213
Manufacturer:
SICK
Find similar products by selecting one or more attributes.
Select all

Brand

SICK

Lock Style

Power

Product Type

Safety Switch

Actuator Included

No

Safety Contacts

1 NO/2 NC

Housing Material

Die Cast Zinc

Series

i110

IP Rating

IP66

Minimum Operating Temperature

-25°C

Contact AC Voltage

240V ac

Contact DC Voltage

24V dc

Switch Contact Current

3A

Maximum Operating Temperature

80°C

Hazardous Area Certification

No

Number of Head Directions

2

Depth

24mm

Standards/Approvals

CE

Length

99mm

Width

65mm

COO (Country of Origin):
PL

SICK i110 Series Safety Switch, 3A Contact Current, IP66 - i110-HA213


This safety switch is an electro-mechanical power lock device designed to monitor access to guards and hazardous openings in industrial settings. It provides a slow-action switching element with a combination of normally closed and normally open contacts and is intended for individual wiring with diagnostics performed by external safety logic. The unit is built for outdoor or wash-down environments where an IP66 enclosure rating and a die-cast zinc housing are required.

Features and Benefits:


• 3A contact current delivers safe switching at industrial voltages
• 240V AC and 24V DC support common control voltages
• Two head directions enable flexible actuator orientation
• Positive-action N/C contacts improve fault-tolerant response
• Temperature range -25°C to 80°C allows wide ambient use

Applications


• Suitable for machine guarding interlocks in manufacturing plants
• Ideal for conveyor access gate monitoring with diagnostics
• Used with safety PLCs requiring slow-action switching elements
• Can be used for outdoor enclosures requiring weatherproof protection
• Appropriate for individually wired safety circuits in non-hazardous areas

What contact configuration is provided?


It provides two positive-action normally closed contacts and one normally open contact.

How should short-circuit protection be specified?


Use a 3A gG fuse or equivalent short-circuit protection sized to the rated insulation and switching current.

What cable termination is required for installation?


A single M20 cable gland is used with conductors up to 1.5mm² cross-section.

How many actuation cycles can be expected mechanically?


The mechanical life is rated at 1x10^6 switching cycles under specified conditions.