Telemecanique Sensors XMP Series Pressure Sensor, 2 NC Output 1.3 bar 12 bar, Differential Reading
- RS Stock No.:
- 221-0136
- Mfr. Part No.:
- XMPR12B2433
- Manufacturer:
- Telemecanique Sensors
Subtotal (1 unit)*
PHP5,279.77
(exc. VAT)
PHP5,913.34
(inc. VAT)
FREE delivery for orders over ₱5,000.00
Temporarily out of stock
- 10 unit(s) shipping from December 07, 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per Unit |
|---|---|
| 1 + | PHP5,279.77 |
*price indicative
- RS Stock No.:
- 221-0136
- Mfr. Part No.:
- XMPR12B2433
- Manufacturer:
- Telemecanique Sensors
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Telemecanique Sensors | |
| Product Type | Pressure Sensor | |
| Pressure Reading Type | Differential | |
| Maximum Pressure Measurement | 12bar | |
| Minimum Pressure Measurement | 1.3bar | |
| Accuracy | 3.5 % | |
| Output Type | 2 NC | |
| Media Measured | Air, Fresh Water, Sea Water | |
| Terminal Type | Screw Clamp | |
| Series | XMP | |
| Standards/Approvals | CE, EN/IEC 60947-4-1 | |
| Housing Material | Fibreglass, Polyamide | |
| Minimum Operating Temperature | -25°C | |
| IP Rating | IP65 | |
| Maximum Operating Temperature | 70°C | |
| Select all | ||
|---|---|---|
Brand Telemecanique Sensors | ||
Product Type Pressure Sensor | ||
Pressure Reading Type Differential | ||
Maximum Pressure Measurement 12bar | ||
Minimum Pressure Measurement 1.3bar | ||
Accuracy 3.5 % | ||
Output Type 2 NC | ||
Media Measured Air, Fresh Water, Sea Water | ||
Terminal Type Screw Clamp | ||
Series XMP | ||
Standards/Approvals CE, EN/IEC 60947-4-1 | ||
Housing Material Fibreglass, Polyamide | ||
Minimum Operating Temperature -25°C | ||
IP Rating IP65 | ||
Maximum Operating Temperature 70°C | ||
- COO (Country of Origin):
- CZ
Telemecanique Sensors XMP Series Pressure Sensor, 12 Bar Maximum Pressure Measurement, 3.5% Accuracy - XMPR12B2433
This pressure sensor monitors differential pressure within industrial systems, converting pressure changes into switch outputs for control and safety tasks. It is designed for use where environmental protection and moderate temperature operation are required and connects via screw-clamp terminals for straightforward panel integration.
Features and Benefits:
• Differential measurement supports precise comparative pressure control
• Maximum measurement range up to 12 bar enables high-pressure monitoring
• Accuracy of 3.5% provides consistent switching thresholds
• Two normally closed outputs allow redundant or dual-circuit control
• IP65-rated enclosure protects against dust and water jets
• Operating range from -25 to 70°C suits varied ambient conditions
• Maximum measurement range up to 12 bar enables high-pressure monitoring
• Accuracy of 3.5% provides consistent switching thresholds
• Two normally closed outputs allow redundant or dual-circuit control
• IP65-rated enclosure protects against dust and water jets
• Operating range from -25 to 70°C suits varied ambient conditions
Applications
• Suitable for pneumatic system pressure monitoring and control
• Ideal for monitoring filter blockage in ventilation equipment
• Used with hydraulic circuits requiring differential detection
• Can be used for compressor safety and shutdown logic
• Suitable for integration in factory automation relay logic
• Ideal for monitoring filter blockage in ventilation equipment
• Used with hydraulic circuits requiring differential detection
• Can be used for compressor safety and shutdown logic
• Suitable for integration in factory automation relay logic
What materials are used for the external casing and why does that matter?
The housing is MADE from fibreglass-reinforced polyamide, which gives chemical resistance and mechanical strength while keeping weight low.
How are electrical connections MADE and what wiring method is required?
Connections use screw-clamp terminals allowing secure conductor attachment and straightforward field wiring with standard tools.
Which standards does it meet for use in electrical control applications?
It complies with EN/IEC 60947-4-1, providing compatibility with established low-voltage control and switching equipment.
How does the output arrangement support system design?
The dual normally closed outputs permit implementation of fail-safe circuits or control of two independent loads without additional relays.
Related links
- Telemecanique Sensors XMP Series Pressure Sensor Differential Reading
- Telemecanique Sensors XMP Series Pressure Sensor Differential Reading
- Telemecanique Sensors XMP Series Pressure Switch, 2 NC Output 1.3 bar 12 bar
- Telemecanique Sensors XMP Series Pressure Sensor Adjustable Differential Reading
- Telemecanique Sensors XMP Series Pressure Sensor 1.3 bar, Differential Reading 12 bar
- Telemecanique Sensors XMP Series Pressure Sensor 1.3 bar 12 bar, Absolute Reading
- Telemecanique Sensors XMP Series Pressure Sensor 0 bar, Differential Reading 12 bar
- Telemecanique Sensors XMP Series Pressure Switch 1.3 bar 12 bar
