Myrra 6 to 2 x 24 V 2 Output Through Hole PCB Transformer, UL 1585, UL 506, EN 61558-2-6, EN 60950 30 VA
- RS Stock No.:
- 173-9557
- Mfr. Part No.:
- 45077
- Manufacturer:
- Myrra
This image is representative of the product range
Currently unavailable
Sorry, we don't know when this will be back in stock.
Alternative
This product is not currently available. Here is our alternative recommendation.
Each
PHP4,601.56
(exc. VAT)
PHP5,153.75
(inc. VAT)
- RS Stock No.:
- 173-9557
- Mfr. Part No.:
- 45077
- Manufacturer:
- Myrra
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Myrra | |
| Product Type | PCB Transformer | |
| Secondary Voltage | 6 to 2 x 24 V | |
| Primary Voltage | 117 V, 230 V | |
| Number of Outputs | 2 | |
| Length | 86mm | |
| Width | 70 mm | |
| Power | 30VA | |
| Depth | 48.5mm | |
| Weight | 700g | |
| Mount Type | Through Hole | |
| Isolation Voltage | 4kV | |
| Maximum Operating Temperature | 250°C | |
| Series | 44000 | |
| Minimum Operating Frequency | 50Hz | |
| Maximum Operating Frequency | 60Hz | |
| Standards/Approvals | UL 1585, UL 506, EN 61558-2-6, EN 60950 | |
| Select all | ||
|---|---|---|
Brand Myrra | ||
Product Type PCB Transformer | ||
Secondary Voltage 6 to 2 x 24 V | ||
Primary Voltage 117 V, 230 V | ||
Number of Outputs 2 | ||
Length 86mm | ||
Width 70 mm | ||
Power 30VA | ||
Depth 48.5mm | ||
Weight 700g | ||
Mount Type Through Hole | ||
Isolation Voltage 4kV | ||
Maximum Operating Temperature 250°C | ||
Series 44000 | ||
Minimum Operating Frequency 50Hz | ||
Maximum Operating Frequency 60Hz | ||
Standards/Approvals UL 1585, UL 506, EN 61558-2-6, EN 60950 | ||
RoHS Status: Not Applicable
- COO (Country of Origin):
- FR
Type UI 48 - 40 VA → 60 VA
Secondary voltages are nominal load voltages on resistive loads.
Only the pins indicated on the wiring diagram "physically" exist.
Encapsulated – Toroidal
Note
Fixing screws not provided
Approvals
UL 506
Standards
IEC 742, VDE 0551, SEV 1003
Related links
- Myrra 18V ac 2 Output Through Hole PCB Transformer, 14VA
- Myrra 18V ac 2 Output Through Hole PCB Transformer, 30VA
- Myrra 18V ac 2 Output Through Hole PCB Transformer, 1VA
- Myrra 18V ac 2 Output Through Hole PCB Transformer, 5VA
- Myrra 18V ac 2 Output Through Hole PCB Transformer, 18VA
- Myrra 18V ac 2 Output Through Hole PCB Transformer, 16VA
- Myrra 18V ac 2 Output Through Hole PCB Transformer, 10VA
- Myrra 18V ac 2 Output Through Hole PCB Transformer, 3.2VA