Myrra 12 V ac 2 Output Through Hole PCB Transformer, EN 61558-2-6, CCA, UL 1585, UL 506, EN 60950 3 VA
- RS Stock No.:
- 173-8879
- Mfr. Part No.:
- 45015
- Manufacturer:
- Myrra
This image is representative of the product range
Bulk discount available
Subtotal (1 unit)*
PHP851.22
(exc. VAT)
PHP953.37
(inc. VAT)
FREE delivery for orders over ₱3,000.00
Temporarily out of stock
- Shipping from March 23, 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per Unit |
|---|---|
| 1 - 24 | PHP851.22 |
| 25 - 49 | PHP817.15 |
| 50 + | PHP783.09 |
*price indicative
- RS Stock No.:
- 173-8879
- Mfr. Part No.:
- 45015
- Manufacturer:
- Myrra
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Myrra | |
| Secondary Voltage | 12 V ac | |
| Product Type | PCB Transformer | |
| Primary Voltage | 117 V, 230 V | |
| Number of Outputs | 2 | |
| Length | 53mm | |
| Width | 44 mm | |
| Power | 3VA | |
| Depth | 17mm | |
| Weight | 700g | |
| Mount Type | Through Hole | |
| Isolation Voltage | 4kV | |
| Maximum Operating Temperature | 250°C | |
| Series | 44000 | |
| Minimum Operating Frequency | 50Hz | |
| Maximum Operating Frequency | 60Hz | |
| Standards/Approvals | EN 61558-2-6, CCA, UL 1585, UL 506, EN 60950 | |
| Select all | ||
|---|---|---|
Brand Myrra | ||
Secondary Voltage 12 V ac | ||
Product Type PCB Transformer | ||
Primary Voltage 117 V, 230 V | ||
Number of Outputs 2 | ||
Length 53mm | ||
Width 44 mm | ||
Power 3VA | ||
Depth 17mm | ||
Weight 700g | ||
Mount Type Through Hole | ||
Isolation Voltage 4kV | ||
Maximum Operating Temperature 250°C | ||
Series 44000 | ||
Minimum Operating Frequency 50Hz | ||
Maximum Operating Frequency 60Hz | ||
Standards/Approvals EN 61558-2-6, CCA, UL 1585, UL 506, EN 60950 | ||
- COO (Country of Origin):
- FR
Type UI 30 - 3 VA → 10 VA
Secondary voltages are nominal load voltages on resistive loads.
Only the pins indicated on the wiring diagram "physically" exist.
Encapsulated – Toroidal
Note
Fixing screws not provided
Approvals
UL 506
Standards
IEC 742, VDE 0551, SEV 1003
Related links
- RS PRO 12V ac 2 Output Through Hole PCB Transformer, 3VA
- Myrra 9V ac 2 Output Through Hole PCB Transformer, 3VA
- Myrra 24V ac 2 Output Through Hole PCB Transformer, 3VA
- Myrra 6V ac 2 Output Through Hole PCB Transformer, 3VA
- Myrra 12V ac 2 Output Through Hole PCB Transformer, 16VA
- Myrra 12V ac 2 Output Through Hole PCB Transformer, 18VA
- Myrra 12V ac 2 Output Through Hole PCB Transformer, 30VA
- Myrra 12V ac 2 Output Through Hole PCB Transformer, 1.5VA
