Fluke 2AC Non Contact Voltage Detector, 90V ac to 1000V ac
- RS Stock No.:
- 741-4355
- Mfr. Part No.:
- FLK2AC/90-1000V
- Manufacturer:
- Fluke
Price Each
PHP2,869.00
(exc. VAT)
PHP3,213.28
(inc. VAT)
3 In stock for delivery within 3 working days*
* Delivery dates may change based on your chosen quantity and delivery address.
Units | Per Unit |
---|---|
1 + | PHP2,869.00 |
- RS Stock No.:
- 741-4355
- Mfr. Part No.:
- FLK2AC/90-1000V
- Manufacturer:
- Fluke
Non Compliant
- COO (Country of Origin):
- MY
Fluke 2AC VoltALERT Non-Contact Voltage Detector
VoltALERT non-contact voltage tester is the new addition to this series by Fluke. Pocket-sized and easy to use, the 2AC tests for defective grounds and energized circuits. A glowing red tip lights up when in close proximity of where voltage is present, such as a terminal strips, power cords or outlet wires.
Two new features on this instrument allow the user to be always at the ready, using special low power circuitry to sustain battery life the 2AC is always on the go. An innovative battery check button also allows users to ensure the battery is in good condition. Finally a clip design optimises pocket and tool bag storage.
Two new features on this instrument allow the user to be always at the ready, using special low power circuitry to sustain battery life the 2AC is always on the go. An innovative battery check button also allows users to ensure the battery is in good condition. Finally a clip design optimises pocket and tool bag storage.
Features and Benefits:
200 - 1000V ac Voltage detection
Battery check button
Category IV – 1000 V overvoltage rated product for best in class user protection
Rugged and reliable
-10°C to 50 °C operating temperature
Battery check button
Category IV – 1000 V overvoltage rated product for best in class user protection
Rugged and reliable
-10°C to 50 °C operating temperature
Frequently asked questions:
What is a non-contact voltage tester used for?
Voltage testers or detectors are used to check the flow of current through a circuit. They can be used to check safety, or to ensure equipment is functioning correctly. They can also test for the current strength, whether the circuit is grounded correctly or to ensure no current is flowing at all so that work can be begin on the circuit.
Voltage testers or detectors are used to check the flow of current through a circuit. They can be used to check safety, or to ensure equipment is functioning correctly. They can also test for the current strength, whether the circuit is grounded correctly or to ensure no current is flowing at all so that work can be begin on the circuit.
How do non-contact voltage testers work?
Also known as a voltage detector, voltage tester pens, sensors or test pens. They allow the user to test electrical conductors without touching them. Non-contact testers are the safest and easiest way to detect electric fields or voltage. Voltage testers utilise what is called capacitive coupling, the user holding the instrument provides a ground reference. The tester then detects changing electric field around the object or objects conducting an AC current. (Alternating current) Simply put, the user and the tester pen when near the electrical conductor will cause a small current to flow through the tester from the source, this is how it detects AC voltage.
Also known as a voltage detector, voltage tester pens, sensors or test pens. They allow the user to test electrical conductors without touching them. Non-contact testers are the safest and easiest way to detect electric fields or voltage. Voltage testers utilise what is called capacitive coupling, the user holding the instrument provides a ground reference. The tester then detects changing electric field around the object or objects conducting an AC current. (Alternating current) Simply put, the user and the tester pen when near the electrical conductor will cause a small current to flow through the tester from the source, this is how it detects AC voltage.
Standards
Safety compliance
Meets IEC 61010-1:2001, UL 61010-1 (2nd ed.), CAN/CSA-C22.2 No. 61010-1-04, and ISA-82.02.01, Pollution Degree 2
Meets IEC 61010-1:2001, UL 61010-1 (2nd ed.), CAN/CSA-C22.2 No. 61010-1-04, and ISA-82.02.01, Pollution Degree 2
FLUKE Non-Contact Voltage Tester, Pocket-Sized, Over 1 Year Battery Life - VoltAlert Series - FLK2AC/90-1000V
Looking for a signal-testing tool that fits right into your pocket? Choose this non-contact voltage tester from FLUKE. Thanks to its integrated clip design, you can hook it in place like a pen so it's always at hand. Its light-up tip tells you what you need to know in an instant, with a blue light for 'closer' and red for voltage. This saves time and hassle. A wide detection span between 90 and 1000V AC makes this a versatile workmate for light-duty to heavy-duty applications.
Features & Benefits
• Typical battery life of over one year for long-lasting performance
• Non-contact voltage detection boosts safety by eliminating the need to touch bare conductor wires
• Suitable for use in challenging settings thanks to an operating temperature range between -10°C and +50°C
• Non-contact voltage detection boosts safety by eliminating the need to touch bare conductor wires
• Suitable for use in challenging settings thanks to an operating temperature range between -10°C and +50°C
Applications
• DIY applications
• Electrical workshops
• Robotics and automation systems
• Electrical workshops
• Robotics and automation systems
How does the battery check function work on this tester?
The battery check function tells you when you're running low on juice. When active, the red LED on the tester beeps twice every two seconds. When it stops beeping like this, you know it's time to change the battery.
Attribute | Value |
---|---|
Indicator Type | Voltage |
Battery Type | AAA |
Audible Tone | No |
Power Source | Battery |
Safety Category | CAT IV 1000 V |
Weight | 45.4g |
Maximum Detection Voltage | 1000V ac |
Maximum Operating Temperature | +50°C |
Minimum Detection Voltage | 90V ac |
Minimum Operating Temperature | -10°C |
Model Number p | 2AC |
Safety Category Voltage | 1000V |
Safety Category Level | CAT IV |