Dold Monitoring Relay, 3 Phase, 0.8 to 1.1 UN Monitor Range, DPDT, DIN Rail
- RS Stock No.:
- 240-8923
- Mfr. Part No.:
- BA9041 3AC50Hz 400V
- Manufacturer:
- Dold
Subtotal (1 unit)*
PHP15,834.33
(exc. VAT)
PHP17,734.45
(inc. VAT)
FREE delivery for orders over ₱3,000.00
In Stock
- 15 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per Unit |
|---|---|
| 1 + | PHP15,834.33 |
*price indicative
- RS Stock No.:
- 240-8923
- Mfr. Part No.:
- BA9041 3AC50Hz 400V
- Manufacturer:
- Dold
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Dold | |
| Product Type | Monitoring Relay | |
| Electrical Phase | 3 | |
| Contact Configuration | DPDT | |
| Mount Type | DIN Rail | |
| Power Consumption | 3.5VA | |
| Switching Voltage | 230 V ac | |
| IP Rating | IP20, IP40 | |
| Contact Current | 5A | |
| Minimum Operating Temperature | -20°C | |
| Monitoring Voltage Range | 0.8 to 1.1 UN | |
| Maximum Operating Temperature | 60°C | |
| Width | 45 mm | |
| Standards/Approvals | IEC/EN 60 715, IEC/EN 60 255-1, IEC/EN 61 000-4-4, IEC/EN 61 000-4-2, IEC/EN 60 999-1, EN 50 005, UL Subject 94, IEC/EN 61 000-4-5, EN 55 011, IEC/EN 60 068-1, IEC/EN 61 000-4-6, IEC/EN 61 000-4-3, IEC/EN 60 947-5-1, DIN 46 228-1/-2/-3/-4, IEC/EN 60 068-2-6 | |
| Height | 73.2mm | |
| Length | 119.8mm | |
| Series | BA 9041 | |
| Select all | ||
|---|---|---|
Brand Dold | ||
Product Type Monitoring Relay | ||
Electrical Phase 3 | ||
Contact Configuration DPDT | ||
Mount Type DIN Rail | ||
Power Consumption 3.5VA | ||
Switching Voltage 230 V ac | ||
IP Rating IP20, IP40 | ||
Contact Current 5A | ||
Minimum Operating Temperature -20°C | ||
Monitoring Voltage Range 0.8 to 1.1 UN | ||
Maximum Operating Temperature 60°C | ||
Width 45 mm | ||
Standards/Approvals IEC/EN 60 715, IEC/EN 60 255-1, IEC/EN 61 000-4-4, IEC/EN 61 000-4-2, IEC/EN 60 999-1, EN 50 005, UL Subject 94, IEC/EN 61 000-4-5, EN 55 011, IEC/EN 60 068-1, IEC/EN 61 000-4-6, IEC/EN 61 000-4-3, IEC/EN 60 947-5-1, DIN 46 228-1/-2/-3/-4, IEC/EN 60 068-2-6 | ||
Height 73.2mm | ||
Length 119.8mm | ||
Series BA 9041 | ||
- COO (Country of Origin):
- MT

Phase sequence relay, BA9041
Detects phase sequence errors and phase failure
with 2 changeovers
Overall width 45 mm
The BA9041 can recognise the phase sequence L1 - L2 - L3 of a three-phase network and therefore avoid an incorrect rotational direction.
The BA9041 phase sequence relay monitors the presence of the 3 phase voltages in a three-phase network in addition to the maintenance of the correct phase sequence. If all 3 phase voltages are present at the device in the correct phase sequence, the output contacts change over from the initial position to the operative position, contacts 11-14 and 21-24 are closed, and a green LED lights up.
If the voltage falls below 60 % UN in one phase, the relay is de-energised (in accordance with: IEC 255, VDE 0435).
Phase Sequence/Failure Relays
Monitoring of 3 phase supplies
Orange housing manufactured to DIN 43 880
DIN rail mount
Related links
- Dold Monitoring Relay 0.8 to 1.1 UN Monitor Range DIN Rail, 400 V ac
- Dold Monitoring Relay 0.8 to 1.1 UN Monitor Range 400 V ac
- Dold Monitoring Relay 0.8 to 1.1 UN Monitor Range 230 V ac, 400 V ac
- Dold Monitoring Relay DPDT, DIN Rail
- Dold Monitoring Relay DPDT 230 V ac, 400 V ac
- Dold Monitoring Relay 0.7 to 1.3 UN Monitor Range DIN Rail 80 to 230 V dc
- Dold Monitoring Relay 0.7 to 1.1 UN Monitor Range DIN Rail
- Dold Monitoring Relay 1 Phase DPDT, DIN Rail 110 to 240 V dc