Honeywell HDLS Series Side Rotary Limit Switch, DPDT, IP65, IP66, IP67, Die Cast Zinc Epoxy Coated Housing, 600V ac, 10A
- RS Stock No.:
- 808-2918
- Mfr. Part No.:
- LSA6B
- Manufacturer:
- Honeywell
Bulk discount available
Subtotal (1 unit)*
PHP23,287.83
(exc. VAT)
PHP26,082.37
(inc. VAT)
FREE delivery for orders over ₱3,000.00
In Stock
- Plus 6 unit(s) shipping from May 04, 2026
- Plus 12 unit(s) shipping from July 20, 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per Unit |
|---|---|
| 1 - 24 | PHP23,287.83 |
| 25 - 49 | PHP22,589.20 |
| 50 + | PHP21,911.52 |
*price indicative
- RS Stock No.:
- 808-2918
- Mfr. Part No.:
- LSA6B
- Manufacturer:
- Honeywell
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Honeywell | |
| Product Type | Limit Switch | |
| Actuator Type | Side Rotary | |
| IP Rating | IP65, IP66, IP67 | |
| Contact Configuration | DPDT | |
| Housing Material | Die Cast Zinc Epoxy Coated | |
| Contact Type | Snap Action | |
| Switching Current | 10A | |
| Series | HDLS | |
| Minimum Operating Temperature | -12°C | |
| Switching DC Voltage | 250V dc | |
| Switching AC Voltage | 600V ac | |
| Maximum Operating Temperature | 121°C | |
| Length | 47.8mm | |
| Width | 45.3mm | |
| Standards/Approvals | CCC, CE, CSA, EN, IEC, RoHS, UL | |
| Depth | 119mm | |
| Hazardous Area Certification | No | |
| Operating Force | 0.45Nm | |
| Mounting Orientation | Side | |
| Mechanical Life | 50000000Cycles | |
| Conduit Entry | 1/2 in to 14 NPT | |
| Select all | ||
|---|---|---|
Brand Honeywell | ||
Product Type Limit Switch | ||
Actuator Type Side Rotary | ||
IP Rating IP65, IP66, IP67 | ||
Contact Configuration DPDT | ||
Housing Material Die Cast Zinc Epoxy Coated | ||
Contact Type Snap Action | ||
Switching Current 10A | ||
Series HDLS | ||
Minimum Operating Temperature -12°C | ||
Switching DC Voltage 250V dc | ||
Switching AC Voltage 600V ac | ||
Maximum Operating Temperature 121°C | ||
Length 47.8mm | ||
Width 45.3mm | ||
Standards/Approvals CCC, CE, CSA, EN, IEC, RoHS, UL | ||
Depth 119mm | ||
Hazardous Area Certification No | ||
Operating Force 0.45Nm | ||
Mounting Orientation Side | ||
Mechanical Life 50000000Cycles | ||
Conduit Entry 1/2 in to 14 NPT | ||
Honeywell HDLS Series Limit Switch, 10A Switching Current, IP65 - LSA6B
This limit switch provides precise mechanical actuation for industrial automation and control tasks where rotary motion requires detection. Designed for side-mounted rotary operation, it offers reliable switching in harsh environments and integrates into electrical systems requiring both AC and DC circuit interruption.
Features and Benefits:
• DPDT snap-action contacts provide clean circuit changeover and flexibility
• Rated switching current 10A for robust load handling
• Switching voltage capability up to 600V AC for high-voltage circuits
• Operates to 250V DC enabling DC control applications
• Withstands temperatures up to 121 °C for elevated-heat environments
• Mechanical endurance of 50 million cycles reduces maintenance frequency
• Rated switching current 10A for robust load handling
• Switching voltage capability up to 600V AC for high-voltage circuits
• Operates to 250V DC enabling DC control applications
• Withstands temperatures up to 121 °C for elevated-heat environments
• Mechanical endurance of 50 million cycles reduces maintenance frequency
Applications
• Suitable for conveyor position detection in manufacturing lines
• Ideal for actuator end-of-travel sensing in valve assemblies
• Used with motor control panels for safety and interlock functions
• Can be used for position feedback in packaging machinery
• Suitable for heavy-duty industrial machine tools requiring rotary sensing
• Ideal for actuator end-of-travel sensing in valve assemblies
• Used with motor control panels for safety and interlock functions
• Can be used for position feedback in packaging machinery
• Suitable for heavy-duty industrial machine tools requiring rotary sensing
What conduit entry does it accept for wiring access?
It accepts a 1/2 in to 14 NPT conduit entry to accommodate standard industrial conduit fittings.
What degree of protection does the enclosure provide against dust and water?
The housing meets IP65, IP66 and IP67 ratings, offering dust-tight protection and resistance to water jets and temporary immersion.
What material is the enclosure MADE from and why does it matter?
The enclosure is manufactured from die-cast zinc, providing structural strength and dimensional stability for demanding installations.
How much torque is required to operate the actuator?
The operating force for the side rotary actuator is 0.45 N·m, enabling predictable actuation in automated linkages.
Approvals
UL, CSA.
Standards
IP65, IP66, IP67
HDLS switches have a IP65, IP66 and IP67 rating. This means they are dust-tight and offer protection against water jets, heavy seas and the effects of immersion.
NEMA 1, 3, 4, 4X, 6, 6P, 12, 13
Type 1: Enclosures that meet Type 1 are for indoor use, and provide some limited protection for the enclosed equipment.
Type 3: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures provide some protection from foreign objects (such as windblown dust) and the ingress of water (such as rain or snow). Enclosures that meet NEMA 3 offer protection against ice forming externally.
Type 4: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures provide some protection from foreign objects (such as falling dirt and windblown dust) and the ingress of water (such as rain, snow or sleet alongside splashing water and hose directed water). Enclosures that meet NEMA 3 offer protection against ice forming externally.
Type 4X: Allows for indoor our outdoor use and provides some ptoection against windust dust and rain, corroision, splashing water and hose directed water.
Type 6: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures provide some protection from foreign objects (such as falling dirt and windblown dust) and the ingress of water (such as rain, snow or sleet alongside splashing water and hose directed water). Enclosures that meet NEMA 4 offer protection against ice forming externally.
Type 6P: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures provide some protection from solid objects (such as falling dirt and windblown dust) and the ingress of water (such as hose directed water). Enclosures that meet the NEMA 6P requirement also offer protection against water when being submerged at a limited depth.
Type 12: Limit switches that meet Type 12 requirements provide limited protection against dust, falling dirt and non-corrosive liquids.
Type 13: Enclosures that meet Type 13 are suited to harsh environments. Enclosures can be used indoors and provide protection against access to hazardous parts. They offer protection against solid objects such as falling dirt, windblown dirt, fibres and lint. They provide a level of protection from dripping and splashing water and other liquids such as spraying splashing and seepage of oil and non-corrosive coolants."
HDLS switches have a IP65, IP66 and IP67 rating. This means they are dust-tight and offer protection against water jets, heavy seas and the effects of immersion.
NEMA 1, 3, 4, 4X, 6, 6P, 12, 13
Type 1: Enclosures that meet Type 1 are for indoor use, and provide some limited protection for the enclosed equipment.
Type 3: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures provide some protection from foreign objects (such as windblown dust) and the ingress of water (such as rain or snow). Enclosures that meet NEMA 3 offer protection against ice forming externally.
Type 4: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures provide some protection from foreign objects (such as falling dirt and windblown dust) and the ingress of water (such as rain, snow or sleet alongside splashing water and hose directed water). Enclosures that meet NEMA 3 offer protection against ice forming externally.
Type 4X: Allows for indoor our outdoor use and provides some ptoection against windust dust and rain, corroision, splashing water and hose directed water.
Type 6: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures provide some protection from foreign objects (such as falling dirt and windblown dust) and the ingress of water (such as rain, snow or sleet alongside splashing water and hose directed water). Enclosures that meet NEMA 4 offer protection against ice forming externally.
Type 6P: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures provide some protection from solid objects (such as falling dirt and windblown dust) and the ingress of water (such as hose directed water). Enclosures that meet the NEMA 6P requirement also offer protection against water when being submerged at a limited depth.
Type 12: Limit switches that meet Type 12 requirements provide limited protection against dust, falling dirt and non-corrosive liquids.
Type 13: Enclosures that meet Type 13 are suited to harsh environments. Enclosures can be used indoors and provide protection against access to hazardous parts. They offer protection against solid objects such as falling dirt, windblown dirt, fibres and lint. They provide a level of protection from dripping and splashing water and other liquids such as spraying splashing and seepage of oil and non-corrosive coolants."