Honeywell GLA Series Adjustable Roller Lever Limit Switch, 1 NO/1 NC, IP67, Die Cast Zinc Housing, 50V
- RS Stock No.:
- 240-2521
- Distrelec Article No.:
- 301-38-721
- Mfr. Part No.:
- GLAC07A2B
- Manufacturer:
- Honeywell
Subtotal (1 unit)*
PHP23,338.78
(exc. VAT)
PHP26,139.43
(inc. VAT)
FREE delivery for orders over ₱3,000.00
In Stock
- 16 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per Unit |
|---|---|
| 1 + | PHP23,338.78 |
*price indicative
- RS Stock No.:
- 240-2521
- Distrelec Article No.:
- 301-38-721
- Mfr. Part No.:
- GLAC07A2B
- Manufacturer:
- Honeywell
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Honeywell | |
| Actuator Type | Adjustable Roller Lever | |
| Product Type | Limit Switch | |
| IP Rating | IP67 | |
| Contact Configuration | 1 NO/1 NC | |
| Housing Material | Die Cast Zinc | |
| Contact Type | Snap Action | |
| Terminal Type | M20 | |
| Series | GLA | |
| Switching AC Voltage | 50V | |
| Minimum Operating Temperature | -25°C | |
| Maximum Operating Temperature | 85°C | |
| Depth | 42mm | |
| Length | 145.8mm | |
| Standards/Approvals | CCC, CE, CSA, UL | |
| Width | 42mm | |
| Hazardous Area Certification | NO | |
| Conduit Entry | 20 mm | |
| Mechanical Life | 15000000Cycles | |
| Select all | ||
|---|---|---|
Brand Honeywell | ||
Actuator Type Adjustable Roller Lever | ||
Product Type Limit Switch | ||
IP Rating IP67 | ||
Contact Configuration 1 NO/1 NC | ||
Housing Material Die Cast Zinc | ||
Contact Type Snap Action | ||
Terminal Type M20 | ||
Series GLA | ||
Switching AC Voltage 50V | ||
Minimum Operating Temperature -25°C | ||
Maximum Operating Temperature 85°C | ||
Depth 42mm | ||
Length 145.8mm | ||
Standards/Approvals CCC, CE, CSA, UL | ||
Width 42mm | ||
Hazardous Area Certification NO | ||
Conduit Entry 20 mm | ||
Mechanical Life 15000000Cycles | ||
- COO (Country of Origin):
- GB




Honeywell GLA Series Limit Switch, 20mm Conduit Entry, Adjustable Roller Lever Actuator - GLAC07A2B
This limit switch is a Compact electromechanical device designed to detect position changes and provide discrete control signals within industrial systems. It is housed in a robust electrostatic epoxy-coated zinc enclosure and connects via an M20 conduit entry. The unit features a roller lever actuator for mechanical interfacing and is suitable for use in automation, electrical and mechanical control loops where a Durable snap-action contact response is required.
Features and Benefits:
• Snap-action contacts deliver Rapid state change for precise control
• 1NO/1NC contact arrangement enables versatile switching logic
• IP67 ingress protection allows operation in wet and dusty conditions
• Mechanical life rated to 15,000,000 operations minimises replacement frequency
• Operating range from -25 to 85°C supports varied ambient temperatures
• Approved to UL, CSA and CE standards for recognised safety acceptance
• 1NO/1NC contact arrangement enables versatile switching logic
• IP67 ingress protection allows operation in wet and dusty conditions
• Mechanical life rated to 15,000,000 operations minimises replacement frequency
• Operating range from -25 to 85°C supports varied ambient temperatures
• Approved to UL, CSA and CE standards for recognised safety acceptance
Applications
• Suitable for conveyor end-of-travel detection in material handling
• Ideal for limit feedback on industrial actuators and valves
• Used with packaging machinery for position verification tasks
• Can be used for safety interlocks in electrical enclosures
• Suitable for heavy-duty machinery requiring high switching cycles
• Ideal for limit feedback on industrial actuators and valves
• Used with packaging machinery for position verification tasks
• Can be used for safety interlocks in electrical enclosures
• Suitable for heavy-duty machinery requiring high switching cycles
What mounting Interface is provided for cable entry?
The enclosure accepts conduit via a 20mm threaded entry compatible with M20 fittings for secure installation.
How does the actuator type affect mechanical interaction?
The adjustable roller lever converts linear or rotary motion into a reliable mechanical trip, allowing fine positioning of the operating point.
What construction detail enhances corrosion resistance?
The metal housing is finished with an electrostatic epoxy coating to reduce surface degradation in demanding environments.
Which contact performance characteristic supports diverse circuit designs?
The device provides one normally open and one normally closed snap-action contact to accommodate complementary control schemes.
Approvals
UL/ UL listed for Canada
Warning
GLA limit switches have not been designed as emergency stop or safety devices. They must not be used in applications where personal injury could occur as a result of the products failing.
Standards
IEC/EN 60947-5-1
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.