ABB GJL131 Contactor, 380V, 415 V Coil, 3-Pole, 20 A, 5.5 kW 380V, 415 V, 3 NO/1 NC, 690V
- RS Stock No.:
- 253-4821
- Mfr. Part No.:
- GJL1311901R8015
- Manufacturer:
- ABB
Subtotal (1 pack of 5 units)*
PHP41,806.05
(exc. VAT)
PHP46,822.80
(inc. VAT)
FREE delivery for orders over ₱3,000.00
Stocked by manufacturer
- Ready to ship from June 08, 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per Unit | Per Pack* |
|---|---|---|
| 5 + | PHP8,361.21 | PHP41,806.05 |
*price indicative
- RS Stock No.:
- 253-4821
- Mfr. Part No.:
- GJL1311901R8015
- Manufacturer:
- ABB
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | ABB | |
| Product Type | Contactor | |
| Coil Voltage | 380, 415V | |
| Number of Poles | 3 | |
| Contact Voltage | 690V | |
| Contact Current | 20A | |
| Power Rating | 5.5kW | |
| Series | GJL131 | |
| Mount Type | DIN Rail, Wall | |
| Function | Reversing Contactor | |
| Normal State Configuration | 3 NO/1 NC | |
| Auxiliary Contact Configuration | 0 NO/1 NC | |
| Number of Auxiliary Contacts | 1 | |
| Terminal Type | Screw | |
| Minimum Operating Temperature | -20°C | |
| Contactor Application | Control Unit | |
| Control Circuit Voltage Uc | 380, 415V | |
| Operational Current Ie | 20A | |
| Maximum Operating Temperature | 55°C | |
| Depth | 46.7mm | |
| Width | 96.2mm | |
| Length | 46.7mm | |
| Standards/Approvals | UL 60947-1, A600, IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-4-1 | |
| Pole and Throw Configuration | 3P | |
| Select all | ||
|---|---|---|
Brand ABB | ||
Product Type Contactor | ||
Coil Voltage 380, 415V | ||
Number of Poles 3 | ||
Contact Voltage 690V | ||
Contact Current 20A | ||
Power Rating 5.5kW | ||
Series GJL131 | ||
Mount Type DIN Rail, Wall | ||
Function Reversing Contactor | ||
Normal State Configuration 3 NO/1 NC | ||
Auxiliary Contact Configuration 0 NO/1 NC | ||
Number of Auxiliary Contacts 1 | ||
Terminal Type Screw | ||
Minimum Operating Temperature -20°C | ||
Contactor Application Control Unit | ||
Control Circuit Voltage Uc 380, 415V | ||
Operational Current Ie 20A | ||
Maximum Operating Temperature 55°C | ||
Depth 46.7mm | ||
Width 96.2mm | ||
Length 46.7mm | ||
Standards/Approvals UL 60947-1, A600, IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-4-1 | ||
Pole and Throw Configuration 3P | ||
- COO (Country of Origin):
- DE
ABB GJL131 Series Contactor, 20A Contact Current, 5.5kW Power Rating - GJL1311901R8015
This contactor is a three-pole switching device designed to control motors and loads across commercial, industrial and residential installations. It operates as a reversing contactor suitable for switching alternating supplies and is intended for mounting on DIN rail or a wall in control panels where compact, robust switching is required.
Features and Benefits:
• 20A operational current provides reliable load handling
• 690V rated contacts permit high-voltage switching capability
• 3NO1NC auxiliary arrangement supports control interlocking
• 380V, 415V Coil options allow flexible control supply selection
• Screw terminals enable secure, high-current connections
• IEC and UL approvals confirm adherence to recognised standards
• 690V rated contacts permit high-voltage switching capability
• 3NO1NC auxiliary arrangement supports control interlocking
• 380V, 415V Coil options allow flexible control supply selection
• Screw terminals enable secure, high-current connections
• IEC and UL approvals confirm adherence to recognised standards
Applications
• Suitable for reversing three-phase motor control up to 5.5 kW
• Ideal for automation panel switching in manufacturing sites
• Used with building services distribution for commercial properties
• Can be used for residential central heating pump control circuits
• Ideal for automation panel switching in manufacturing sites
• Used with building services distribution for commercial properties
• Can be used for residential central heating pump control circuits
What ambient temperatures can it be installed in?
It is specified for operation between -20°C and 55°C, permitting use in a wide range of environments.
How is it mounted within control equipment?
The device accepts DIN-rail mounting and can alternatively be fixed to a wall or panel surface for versatile installation.
How many poles and auxiliary contacts are available?
It provides three main poles for load switching and one additional auxiliary contact arranged normally open and normally closed for control logic.
What power level is suitable for motor switching?
The contactor is rated for motor control up to 5.5 kW at its specified operating current.
Related links
- ABB GJL131 Contactor 415 V 415 V Coil 12 A 415 V 690V
- ABB GJL131 Contactor 415 V 415 V Coil 20 A 415 V 690V
- ABB GJL121 Contactor 415 V Coil 20 A 415 V 690V dc
- ABB GJL121 Contactor 415 V 415 V Coil 12 A 3 NO/1 NC, 690V
- ABB GJL121 Contactor 415 V 415 V Coil 20 A 3 NO/1 NC, 690V
- ABB GJL121 Contactor 415 V Coil 20 A 3 NO/1 NC, 690V
- ABB GJL131 Contactor 127 V 127 V Coil 12 A 127 V 690V
- ABB GJL131 Contactor 240 V dc 240 V dc Coil 20 A 240 V 690V