FLIR VT8 Clamp Meter, 200 A 200 A 1000 V dc 1000 V ac CAT III, CAT IV Non-Contact Voltage Detector
- RS Stock No.:
- 181-2426
- Distrelec Article No.:
- 301-25-653
- Mfr. Part No.:
- VT8-600
- Manufacturer:
- FLIR
- RS Stock No.:
- 181-2426
- Distrelec Article No.:
- 301-25-653
- Mfr. Part No.:
- VT8-600
- Manufacturer:
- FLIR
Select all | Attribute | Value |
|---|---|---|
| Brand | FLIR | |
| Product Type | Clamp Meter | |
| Maximum DC Current Measurement | 200A | |
| Maximum AC Voltage Measurement | 1000V ac | |
| Maximum DC Voltage Measurement | 1000V dc | |
| Maximum Resistance Measurement | 60MΩ | |
| Model Number | VT8 | |
| DC Voltage Resolution | 100 mV dc | |
| AC Current Accuracy | ±2.5 % | |
| DC Voltage Accuracy | ±1 % | |
| DC Current Resolution | 100mA | |
| Resistance Measurement Accuracy | ±1.5 % | |
| AC Current Resolution | 100mA | |
| Minimum Operating Temperature | 10°C | |
| AC Voltage Accuracy | ±1 % | |
| AC Voltage Resolution | 100mV ac | |
| Maximum Jaw Opening | 15.5mm | |
| DC Current Accuracy | ±2.5 % | |
| Clamp Meter Type | AC-DC Open Jaw Clamp Meter | |
| Maximum Operating Temperature | 50°C | |
| Standards/Approvals | No | |
| Width | 35mm | |
| Length | 210mm | |
| Height | 53mm | |
| Weight | 163.7g | |
| True RMS | Yes | |
| Functions Measured | AC Current, AC Voltage, Auto Ranging, Capacitance, Continuity, Data Hold, DC Current, DC Voltage, NCV (Non-contact Voltage), Relative Mode, Resistance, True RMS | |
| Maximum AC Current Measurement | 200A | |
| Maximum Temperature Measurement | 60°C | |
| Non-Contact Voltage Detector | Yes | |
| Safety Category Level | CAT III, CAT IV | |
| Battery Type | AA | |
| Display Type | LCD | |
| Safety Category Voltage | 600V | |
| Power Source | Battery | |
| Select all | ||
|---|---|---|
Brand FLIR | ||
Product Type Clamp Meter | ||
Maximum DC Current Measurement 200A | ||
Maximum AC Voltage Measurement 1000V ac | ||
Maximum DC Voltage Measurement 1000V dc | ||
Maximum Resistance Measurement 60MΩ | ||
Model Number VT8 | ||
DC Voltage Resolution 100 mV dc | ||
AC Current Accuracy ±2.5 % | ||
DC Voltage Accuracy ±1 % | ||
DC Current Resolution 100mA | ||
Resistance Measurement Accuracy ±1.5 % | ||
AC Current Resolution 100mA | ||
Minimum Operating Temperature 10°C | ||
AC Voltage Accuracy ±1 % | ||
AC Voltage Resolution 100mV ac | ||
Maximum Jaw Opening 15.5mm | ||
DC Current Accuracy ±2.5 % | ||
Clamp Meter Type AC-DC Open Jaw Clamp Meter | ||
Maximum Operating Temperature 50°C | ||
Standards/Approvals No | ||
Width 35mm | ||
Length 210mm | ||
Height 53mm | ||
Weight 163.7g | ||
True RMS Yes | ||
Functions Measured AC Current, AC Voltage, Auto Ranging, Capacitance, Continuity, Data Hold, DC Current, DC Voltage, NCV (Non-contact Voltage), Relative Mode, Resistance, True RMS | ||
Maximum AC Current Measurement 200A | ||
Maximum Temperature Measurement 60°C | ||
Non-Contact Voltage Detector Yes | ||
Safety Category Level CAT III, CAT IV | ||
Battery Type AA | ||
Display Type LCD | ||
Safety Category Voltage 600V | ||
Power Source Battery | ||
- COO (Country of Origin):
- CN
FLIR Clamp metre, AC-DC, True RMS - VT8-600
Features & Benefits
Applications
Can it measure both AC and DC voltage and current accurately?
Will it help me detect live AC voltages without contact?
Is it suitable for professionals working in the automation industry?
Related links
- FLIR VT8 Clamp Meter CAT IV Non-Contact Voltage Detector
- Fluke 376 Clamp Meter CAT IV Non-Contact Voltage Detector
- RS PRO 156B Clamp Meter CAT IV Non-Contact Voltage Detector
- Extech PQ2071 Clamp Meter 1000 A 750 V ac CAT III, CAT IV Non-Contact Voltage Detector
- RS PRO 158B Clamp Meter CAT IV Non-Contact Voltage Detector
- RS PRO 155B Clamp Meter 99 A 999.9 V dc 999.9 V ac CAT III, CAT IV Non-Contact Voltage Detector
- RS PRO Clamp Meter CAT IV Non-Contact Voltage Detector
- Fluke 381 Clamp Meter CAT III Non-Contact Voltage Detector