ABB Auxiliary Contact, 2 Contact, 1 NO/1 NC, CAF6-11M, Front, 6 A, 240 V dc, 500V ac, GJL1201330R0003 - CAF6-11M
- RS Stock No.:
- 445-8166
- Mfr. Part No.:
- GJL1201330R0003 - CAF6-11M
- Manufacturer:
- ABB
This image is representative of the product range
Subtotal (1 unit)*
PHP785.98
(exc. VAT)
PHP880.30
(inc. VAT)
FREE delivery for orders over ₱3,000.00
In Stock
- 34 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per Unit |
|---|---|
| 1 + | PHP785.98 |
*price indicative
- RS Stock No.:
- 445-8166
- Mfr. Part No.:
- GJL1201330R0003 - CAF6-11M
- Manufacturer:
- ABB
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | ABB | |
| Product Type | Auxiliary Contact | |
| Number of Contacts | 2 | |
| Normal State Configuration | 1 NO/1 NC | |
| Series | CAF6-11M | |
| Mount Type | Front | |
| Contact Current | 6A | |
| Terminal Type | Screw | |
| Pole and Throw Configuration | 2P | |
| Contact Voltage | 240, 500V dc | |
| Minimum Operating Temperature | -25°C | |
| Operational Current Ie | 6A | |
| Mounting Location | Front Side | |
| Rated Insulation Voltage Ui | 690V | |
| Maximum Operating Temperature | 55°C | |
| Standards/Approvals | IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC/EN 60947-4-1, IEC/EN 60947-1 | |
| Select all | ||
|---|---|---|
Brand ABB | ||
Product Type Auxiliary Contact | ||
Number of Contacts 2 | ||
Normal State Configuration 1 NO/1 NC | ||
Series CAF6-11M | ||
Mount Type Front | ||
Contact Current 6A | ||
Terminal Type Screw | ||
Pole and Throw Configuration 2P | ||
Contact Voltage 240, 500V dc | ||
Minimum Operating Temperature -25°C | ||
Operational Current Ie 6A | ||
Mounting Location Front Side | ||
Rated Insulation Voltage Ui 690V | ||
Maximum Operating Temperature 55°C | ||
Standards/Approvals IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC/EN 60947-4-1, IEC/EN 60947-1 | ||
RoHS Status: Exempt
- COO (Country of Origin):
- DE
ABB CAF6-11M Series Auxiliary Contact, 6A Contact Current, 690V Rated Insulation Voltage - GJL1201330R0003 - CAF6-11M
This auxiliary contact provides a Compact front-mounted switching Interface for mini contactors, enabling signalling and interlocking functions in control panels. Designed for use on the front side of compatible contactors, it delivers low-voltage switching for auxiliary circuits in automation and electrical installations while maintaining industry-standard safety and connection practices.
Features & Benefits
• 1NO1NC configuration for versatile control and feedback
• 6A operational current Ie for modest auxiliary loads
• Rated insulation voltage 690V Ui for high-voltage separation
• Screw Terminal front mount for secure field wiring
• Operates between -25 and +55°C for site flexibility
• IEC and UL approvals for recognised conformity in installations
• 6A operational current Ie for modest auxiliary loads
• Rated insulation voltage 690V Ui for high-voltage separation
• Screw Terminal front mount for secure field wiring
• Operates between -25 and +55°C for site flexibility
• IEC and UL approvals for recognised conformity in installations
Applications
• Suitable for signalling status of control contactors in motor starters
• Ideal for interlock functions in industrial control panels
• Used with mini contactors to expand auxiliary switching capacity
• Can be used for remote indication circuits in automation systems
• Ideal for interlock functions in industrial control panels
• Used with mini contactors to expand auxiliary switching capacity
• Can be used for remote indication circuits in automation systems
What wire sizes can be terminated into the connections?
The terminals accept flexible ferrules or stranded conductors up to 2.5mm² and solid conductors up to 4mm² for reliable clamping.
How is the contact Block mounted on a contactor?
It mounts on the front side of compatible mini contactors using a dedicated front mounting Interface with screw terminals for electrical connection.
What environmental conditions can it tolerate in service?
It is rated for operation at altitudes up to 2000m and survives storage temperatures down to -40°C with operational ambient range -25 to +55°C.
Which standards cover its electrical and mechanical performance?
Its conformity includes IEC/EN 60947-1, IEC/EN 60947-4-1 and IEC/EN 60947-5-1 Plus corresponding UL listings for use in certified systems.
Related links
- ABB Auxiliary Contact 1 NO/1 NC Front 250.69kV, GJL1201330R0003 CAF6-11M
- ABB Auxiliary Contact 2 NO Front 240 V dc GJL1201330R0007 CAF6-20M
- Eaton Auxiliary Contact 1 NO/1 NC Top 220 V dc 072896 NHI11-PKZ0
- Eaton Auxiliary Contact 1 NO/1 NC 4 A 500V ac, 010224 11DILE
- Eaton Auxiliary Contact 1 NO/1 NC Front 220 V dc 010080 11DILEM
- Eaton Auxiliary Contact 2 NC 4 A 500V ac, 010064 02DILEM
- Eaton Auxiliary Contact 2 NC Top 500V ac, 072899 AGM2-01-PKZ0
- ABB Auxiliary Contact 2 NC Front 500V ac, GJL1201330R0011 CAF6-02M