An RCD (residual current device), has been designed to protect you from fatal electric shocks as it automatically switches off electricity when there is a fault. This potentially life-saving device protects against electrocution in instances where there is a bare wire, over-heating or earth faults.RCDs are also known as an RCCB (residual-current circuit breaker) in the UK but in the United States and Canada they are referred to as a GFCI (ground fault circuit interrupter).If RCDs are regularly tested, they are reliable life-saving devices, reducing the risk of electric shock and protecting your home against electrical fires.How does an RCD work?An RCD is placed within the circuits it has to protect. By monitoring the electric current, it can quickly detect when a circuit fails and electricity is flowing incorrectly. When the fault is detected, the RCD switches off the circuit so that the person handling the wires comes to no harm.RCDs are often integrated with a fuse or MCB (miniature circuit breaker) adding protection when there are excessive current causing spikes or surges in the circuit.Types of RCD
  • Fixed RCDs: they are installed in a fuse box and are used for both industrial and domestic applications. They protect lots of circuits and provide an excellent level of protection. RCDs located within a consumer power distribution unit are mostly passive. This allows household appliances to re-establish normal operation when the circuit power is restored.
  • Socket-Outlet RCDs: they provide individual protection to the person who is in contact with the equipment. They can be used in place of a standard socket outlet. Socket-outlet RCDs are either active or passive. They are latching in operation so are not ideal for power tools which do not require a restart when the circuit is restored.
  • Portable RCDs: they also only provide individual protection to the person who is in contact with the equipment. They plug into any standard socket, and the appliance is then plugged into the RCD. Portable RCDs are mostly active and unlatch when any abnormality is detected. People who use outside power tools would benefit from a portable RCD as their equipment could become dangerous if they were suddenly reactivated.

...
Read more Read less

Filters

Viewing 1 - 20 of 384 products
Results per page
Description Price Number of Poles Current Rating Model Number Trip Sensitivity Rated AC Voltage Rated DC Voltage Mounting Style Range Break Time Series Application Breaking Capacity Circuit Breaker Type Earth Leakage Protection Type
RS Stock No. 538-3861
Mfr. Part No.2CSF204001R3900
BrandABB
PHP17,594.59
Each
units
4 100 A - 300mA - - DIN Rail System M Pro - F200 - - - -
RS Stock No. 538-3855
Mfr. Part No.2CSF204001R1900
BrandABB
PHP18,512.61
Each
units
4P 100 A - 30mA - - DIN Rail Mount System M Pro - F200 - - - -
RS Stock No. 812-9544
PHP1,856.76
Each
units
2P 40 A - 30mA 240 V - DIN Rail Mount Domae Instantaneous DOM - - - -
RS Stock No. 511-9121
Mfr. Part No.ELRM44V-30
PHP8,067.47
Each
units
- 8 A - 30 30000mA 115 230 V - DIN Rail Mount - Instantaneous, Time Delay ELRM - - - -
RS Stock No. 124-7734
Mfr. Part No.5SV3346-6
BrandSiemens
PHP15,395.17
Each
units
4 63 A - 30mA 400 V ac - DIN Rail Sentron Instantaneous 5SV3 Industrial, Non-Residential, Residential - RCCB -
RS Stock No. 922-8626
Mfr. Part No.PFIM-40/4/03-MW
BrandEaton
PHP6,755.74
Each
units
4 40 A - 300mA 230 400 V - DIN Rail PFIM Instantaneous PFIM - - RCCB -
RS Stock No. 922-8749
Mfr. Part No.PKNM-25/1N/C/003-MW
BrandEaton
PHP6,192.94
Each
units
2 25 A - 30mA 230 V - DIN Rail PKNM Instantaneous PKNM - - MCB, RCD -
RS Stock No. 610-3773
Mfr. Part No.2CSB202101R1250 - DDA202A-25/0.03
BrandABB
PHP4,992.61
Each
units
2 25 A - 30mA 415 V - DIN Rail pro M compact - DDA 200 A - - - -
RS Stock No. 922-8660
Mfr. Part No.PFIM-25/4/03-A-MW
BrandEaton
PHP7,734.70
Each
units
4 25 A - 300mA 230 400 V - DIN Rail PFIM Instantaneous PFIM - - RCCB -
RS Stock No. 776-9090
Mfr. Part No.A9R75240
PHP1,773.07
Each
units
DP 40 A - 300mA 230 V, 240 V - DIN Rail Mount Acti 9 Instantaneous iIDK - - - -
RS Stock No. 610-3802
Mfr. Part No.2CSB202101R3250 - DDA202A-25/0.3
BrandABB
PHP5,612.16
Each
units
2 25 A - 300mA 415 V - DIN Rail pro M compact - DDA 200 A - - - -
RS Stock No. 790-7298
Mfr. Part No.A9D31620
PHP10,075.00
Each
units
2 20 A - 30mA 230 V - DIN Rail Acti 9 - iDPN - - - -
RS Stock No. 734-9217
Mfr. Part No.A9Q11340
PHP17,231.37
Each
units
- 40 A - 30mA 415 V - DIN Rail Mount Acti 9 Instantaneous iC60 - - - -
RS Stock No. 826-3335
Mfr. Part No.7840S
PHP3,969.17
Each
units
2 40 A - 30mA 230 V - DIN Rail Sentry Selective 7840S - - - -
RS Stock No. 922-8623
Mfr. Part No.PFIM-25/4/03-MW
BrandEaton
PHP5,540.51
Each
units
4 25 A - 300mA 230 400 V - DIN Rail PFIM Instantaneous PFIM - - RCCB -
RS Stock No. 776-2856
Mfr. Part No.A9N18542
PHP51,162.66
Each
units
- 125 A - 30mA 230 415 V - DIN Rail Mount Acti 9 Instantaneous C120 - - - -
RS Stock No. 922-8617
Mfr. Part No.PFIM-63/2/003-MW
BrandEaton
PHP6,623.68
Each
units
2 63 A - 30mA 230 400 V - DIN Rail PFIM Instantaneous PFIM - - RCCB -
RS Stock No. 790-7289
Mfr. Part No.A9D31616
PHP11,493.70
Each
units
2 16 A - 30mA 230 V - DIN Rail Acti 9 - iDPN - - - -
RS Stock No. 610-3868
Mfr. Part No.2CSB203101R1250 - DDA203A-25/0.03
BrandABB
PHP6,342.08
Each
units
3 25 A - 30mA 415 V - DIN Rail pro M compact - DDA 200 A - - - -
RS Stock No. 667-0605
Mfr. Part No.235390
BrandEaton
PHP5,801.22
Each
units
2 25 A - 30mA - - DIN Rail XBoard - PFIM - - - -
Related Products
Voltage surges, often referred to as spikes or ...
Description:
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage surges are usually caused by lightning and can reach up to 6000V, with current ...
Voltage surges, often referred to as spikes or ...
Description:
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage surges are usually caused by lightning and can reach up to 6000V, with current ...
Acti9 Vigi C120 Add on RCDs provide protection ...
Description:
Acti9 Vigi C120 Add on RCDs provide protection of persons against electric shock by direct and indirect contact and protection of installations against fire hazards. Class-2 insulationRating: 20 to 125 AFault indication by the red strip on the reset toggleScrew ...
The Acti 9 iID DIN rail RCCBs, are ...
Description:
The Acti 9 iID DIN rail RCCBs, are fully coordinated with the iC60 MCBs to warranty an absolute people and equipment protection against electrocution, risk of fire and improved continuity of service. Protection of persons against electric shock by direct ...