GEORGIN 1 Channel Double Zener Barrier, Process Signal, ATEX
- RS Stock No.:
- 230-9458
- Mfr. Part No.:
- BZG767PLUS
- Manufacturer:
- GEORGIN
Subtotal (1 box of 1 unit)*
PHP12,883.90
(exc. VAT)
PHP14,429.97
(inc. VAT)
FREE delivery for orders over ₱3,000.00
Temporarily out of stock
- Shipping from June 15, 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Box(es) | Per Box |
|---|---|
| 1 + | PHP12,883.90 |
*price indicative
- RS Stock No.:
- 230-9458
- Mfr. Part No.:
- BZG767PLUS
- Manufacturer:
- GEORGIN
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | GEORGIN | |
| Number of Channels | 1 | |
| Product Type | Double Zener Barrier | |
| Barrier Type | Zener Barrier | |
| Mount Type | DIN Rail | |
| Hazardous Area Certification | ATEX | |
| Terminal Type | Screw | |
| IP Rating | IP20 | |
| Maximum Safety Voltage | 13.8V | |
| Minimum Operating Temperature | -20°C | |
| Signal Type | Process Signal | |
| Maximum Safety Current | 302.84mA | |
| Maximum Operating Temperature | 60°C | |
| Standards/Approvals | ATEX EN 60079-0/EN 60079-11/EN 60079-15/EN 61241-11/EN 61241-0, IECEx IEC 60079-0/IEC 60079-11/IEC 60079-15/IEC 61241-11/IEC 61241-0, SIL EN 61508, C.E.M. EN 61326-1 & IEC61000-6-2, D.B.T. NFC 15-100 | |
| Series | BZG | |
| Select all | ||
|---|---|---|
Brand GEORGIN | ||
Number of Channels 1 | ||
Product Type Double Zener Barrier | ||
Barrier Type Zener Barrier | ||
Mount Type DIN Rail | ||
Hazardous Area Certification ATEX | ||
Terminal Type Screw | ||
IP Rating IP20 | ||
Maximum Safety Voltage 13.8V | ||
Minimum Operating Temperature -20°C | ||
Signal Type Process Signal | ||
Maximum Safety Current 302.84mA | ||
Maximum Operating Temperature 60°C | ||
Standards/Approvals ATEX EN 60079-0/EN 60079-11/EN 60079-15/EN 61241-11/EN 61241-0, IECEx IEC 60079-0/IEC 60079-11/IEC 60079-15/IEC 61241-11/IEC 61241-0, SIL EN 61508, C.E.M. EN 61326-1 & IEC61000-6-2, D.B.T. NFC 15-100 | ||
Series BZG | ||
Zener barriers contribute to the intrinsic safety [Ex i] and are installed in safe areas. Their mission is to limit the level of energy that may appear in an electric circuit routed through a potentially explosive area, whatever the connection established upstream of the barrier.
A barrier is made up of:
- resistors that limit the current
- Zener diodes that limit the voltage
- fuses that protect the components
When a fault voltage is applied across the input terminals of the barrier, the voltage that may appear in the explosive zone is limited by a Zener diode, which is in turn protected by a fuse.
The current is limited to an acceptable value by the resistor.
They can be installed in zone 2, thanks to the Ex nA certification in an IP 54 housing.
Zener barrier for logic signals
Polyester enclosure / DIN Rail mounting
For floating potential wiring
3/4: U0=15.79V I0=83.08mA P0=327.85mW
2/3: Ua=13.8V Ifm=100mA RL=103.6ohm
Number of channels: 1
Screw terminals
ATEX / IECEx informations:
INERIS 11ATEX0024X / IECEx INE11.0009X
Group II (surface) - category (1) G/D
II(1) GD [Ex ia Ga] IIC, IIB or [Ex iaD Da] IIIC
II3(1) G Ex nA [ia Ga] IIC T4 Gc
Installation in safe zone or zone 2
For equipment installed in zone 0,1,2,20,21,22
See leaflet for a safe use