Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | PR Electronics | |
| Minimum Temperature Input | -200°C | |
| Series | 5300 | |
| Select all | ||
|---|---|---|
Brand PR Electronics | ||
Minimum Temperature Input -200°C | ||
Series 5300 | ||
- COO (Country of Origin):
- DK
Sensor Inputs
The PR 5333 programmable transmitter provides unrivalled input versatility from 2 & 3 Wire RTD or linear resistance up to 10 kΩ. Input sensor redundancy function maintains process availability and safety in the event of primary sensor failure.
5300 Series - In-Head Temperature Transmitter
PR Electronics 5300 series single input temperature transmitter offers unrivalled performance In applications making heavy demands on accuracy to convert a wide array of input types to a 4 – 20 mA output signal. The 5300 series transmitters are quickly and easily programmable to the specific application. Configuration via a standard PC and user-friendly software, PReset, available as a free download. Parameters for input, output, sensor error detection and process calibration can be configured via PReset within a few minutes.
Features and Benefits
• For DIN form B sensor head mounting
• Sensor drift detection maintains measuring point reliability
• Flexible input capability, with choice of output modes
• Superior accuracy ensures true, reliable measurements
• Fast response time easily supports safety and cost-critical applications
• High immunity to conducted noise: tested against 10 Vrms in the range 15 Hz–100 MHz
• Continuous check of vital stored data for safety reasons
• Runtime meters provide a valuable history of the process temperature and the ambient temperature around the transmitter
• Very low temperature coefficient ensuring maximum accuracy across changing ambient conditions
Related links
- PR Electronics 6333B Temperature Transmitter RTD Input 30V dc -40 °C
- PR Electronics 6300 Temperature Transmitter RTD 85 °C, -40 °C
- PR Electronics Temperature Transmitter RTD Input 35V -40 °C
- PR Electronics 5333A Temperature Transmitter RTD Input 35V dc -40 °C
- PR Electronics 6400 Temperature Transmitter Thermocouple RTD Input 30V dc -50 °C
- PR Electronics 6400 Temperature Transmitter RTD Thermocouple Input 30V dc -50 °C
- PR Electronics 5300 Temperature Transmitter Thermocouple Voltage Input 30V dc -40 °C
- PR Electronics 6300 Temperature Transmitter RTD Input 35V -40 °C