TDK-Lambda Switching Power Supply, NV1-4G5FF 4 Output 24V dc, 8A, 180 W, Input 90V ac to 370 V dc, 265V ac
- RS Stock No.:
- 200-162
- Mfr. Part No.:
- NV1-4G5FF
- Manufacturer:
- TDK-Lambda
Bulk discount available
Subtotal (1 unit)*
PHP15,920.88
(exc. VAT)
PHP17,831.39
(inc. VAT)
FREE delivery for orders over ₱3,000.00
Temporarily out of stock
- 17 unit(s) shipping from May 08, 2026
- Plus 10 unit(s) shipping from May 19, 2026
- Plus 3 unit(s) shipping from May 26, 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per Unit |
|---|---|
| 1 - 9 | PHP15,920.88 |
| 10 - 49 | PHP15,443.27 |
| 50 + | PHP14,979.96 |
*price indicative
- RS Stock No.:
- 200-162
- Mfr. Part No.:
- NV1-4G5FF
- Manufacturer:
- TDK-Lambda
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | TDK-Lambda | |
| Product Type | Switching Power Supply | |
| Maximum Output Voltage | 24V dc | |
| Number of Outputs | 4 | |
| Mount Type | Chassis | |
| Power | 180W | |
| SMPS Output Current | 8A | |
| Minimum Operating Temperature | 0°C | |
| Maximum Operating Temperature | 70°C | |
| Weight | 250g | |
| Standards/Approvals | EN 60601-1-2:2007, EN 61000-4-11, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-6-2:2005, EN 61000-6-3:2007 | |
| Width | 76.2mm | |
| Depth | 31.75mm | |
| Length | 127mm | |
| Efficiency | 90% | |
| Maximum Input Voltage | 370, 265V dc | |
| Series | NV1 | |
| Minimum Input Voltage | 90V ac | |
| Hazardous Area Certification | NO | |
| Select all | ||
|---|---|---|
Brand TDK-Lambda | ||
Product Type Switching Power Supply | ||
Maximum Output Voltage 24V dc | ||
Number of Outputs 4 | ||
Mount Type Chassis | ||
Power 180W | ||
SMPS Output Current 8A | ||
Minimum Operating Temperature 0°C | ||
Maximum Operating Temperature 70°C | ||
Weight 250g | ||
Standards/Approvals EN 60601-1-2:2007, EN 61000-4-11, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-6-2:2005, EN 61000-6-3:2007 | ||
Width 76.2mm | ||
Depth 31.75mm | ||
Length 127mm | ||
Efficiency 90% | ||
Maximum Input Voltage 370, 265V dc | ||
Series NV1 | ||
Minimum Input Voltage 90V ac | ||
Hazardous Area Certification NO | ||
175-180W, Universal Input, 3x5 inch, Single & Multi Outputs, NV175 Series
Miniature size 3x5 inch, high power density
Low profile, fits 1U applications
No minimum load
Up to 90% efficiency
Adjustable output voltage on outputs 1, 2 and 3
Medical safety approved to EN 60601-1
Power factor correction to EN 61000-3-2
EMC meets EN 55022-B (as per CISPR.22)
Remote sense on outputs 1 & 2
Short circuit and over voltage and over temperature protection
Switch Mode - TDK-Lambda
Note
Output current is with 2m/s air flow. Derate above 50°C to 70°C each output by 2.5% per °C. Ripple & Noise (P-P Max) is 50mV or 1% if greater.
Approvals
UL recognised component for US, CSA
Standards
EN 60950-1, UL 60950-1, CSA 22.2 No. 60950, IEC 60950-1, IEC 60601-1