Omron G3PE Series solid state relays with heat sinks for a wide range of applications.
Models also available with no zero cross
Compact with a slim profile
Improved surge dielectric strength for output circuits
Screw and DIN track mounting possible
RoHS compliant
The G3PE SSR – Solid State Relay series have a slim compact design complete with built-in heat sinks. Solid state contactors for 3-phase heaters, reduced installation and available to DIN rail mount or screw mount. RoHS compliant with surge protection.
Three-phase.
Phototriac coupler.
Yellow indicator.
Rated input voltage 12 to 24 V dc.
Zero cross function.
DIN Rail Mounting available
Applicable load 15 A, 100 to 240 V ac. (dependent upon the ambient temperature).
3 Poles.
Built-in heat sink.
Operating voltage range 9.6 to 30 V dc.
Rated input current 10 mA max. (24 V dc).
Must operate voltage 9.6 V dc max.
Must release voltage 1 V dc max.
Rated load voltage 100 to 240 V ac, 50 / 60 Hz.
Load voltage range 75 to 264 V ac, 50 / 60 Hz.
Applicable load current 15 A at 40°C. (dependent upon the ambient temperature).
Load current minimum 0.2 A.
Inrush current 150 A, 60 Hz, 1 cycle. Peak value.
Resistive load 5.1 kW at 200 V ac.
Operate and release time load power source cycle + 1 ms max.
Output ON voltage drop 1.6 V (RMS) max.
Leakage current 10 mA max at 200 v ac.
Vibration resistance 10 to 55 to 10 Hz, 0.175 single amplitude, 0.33 mm double amplitude – DIN rail mounted.
Vibration resistance 10 to 55 to 10 Hz, 0.375 single amplitude, 0.75 mm double amplitude – Screw mounted.
Shock resistance destruction 294 m/s² DIN rail mounted.
Operating temperature – ambient -30°C to 80°C, no icing or condensation.
Relay weight 1.25 kg.
Zero cross function will allow the relay to turn ON when the AC load power supply approaches 0 V suppressing any noise generated with a sudden load current increase. Zero cross function is effective across 2 types of noise, noise on power lines and noise emitted into open space.
UL508, CSA22.2 No.14, EN 60947-4-3.
Attribute | Value |
---|---|
Minimum Load Current | 0.2 A |
Maximum Load Current | 15 A |
Series | G3PE Three Phase |
Mounting Type | DIN Rail |
Minimum Load Voltage | 75 V ac |
Maximum Load Voltage | 264 V ac |
Minimum Control Voltage | 9.6 V dc |
Maximum Control Voltage | 30 V dc |
Switching Type | Zero Crossing |
Contact Configuration | 3P-NO |
Terminal Type | Screw |
Output Device | Phototriac Coupler |
Maximum Turn On Time | 1 (+1/2 cycle) ms |
Dimensions | 80 x 155 x 100mm |
Off State Leakage Current | 10 mA |
Height | 100 |
Depth | 155mm |
Maximum Operating Temperature | +80°C |
Control Voltage Range | 9.6 → 30 V dc |
Operating Temperature Range | -30 → +80°C |
Load Voltage Range | 75 → 264V ac |
Length | 80 |