Wieland SNO 4083, 24V dc Safety Relay, 3 Safety Contacts, 1

Subtotal (1 unit)*

PHP28,526.66

(exc. VAT)

PHP31,949.86

(inc. VAT)

Add to Basket
Select or type quantity
In Stock
  • Plus 17 unit(s) shipping from April 27, 2026
  • Plus 2 unit(s) shipping from May 04, 2026
  • Plus 6 unit(s) shipping from May 14, 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per Unit
1 +PHP28,526.66

*price indicative

RS Stock No.:
780-5073
Mfr. Part No.:
R1.188.3580.0
Manufacturer:
Wieland
Find similar products by selecting one or more attributes.
Select all

Brand

Wieland

Product Type

Safety Relay

Safety Contacts

3

Contact Configuration

NOC

Number of Auxiliary Contacts

1

Reset Method

Manual

Mount Type

DIN Rail

Series

SNO 4083

Power Consumption

1.6W

Terminal Type

Screw

Time Delay

1.5 s

IP Rating

IP40

Switching AC Voltage

230V ac

Switching DC Voltage

24V dc

Standards/Approvals

EN 50156-1, EN ISO 13849-1, EN 62061, EN 81-1

Contact Current

6A

Minimum Operating Temperature

-25°C

Maximum Operating Temperature

65°C

Width

22.5mm

Height

114mm

Length

96.5mm

Hazardous Area Certification

No

Safety Category

4

Coil Voltage

24V dc

COO (Country of Origin):
DE

Wieland SNO 4083KM Safety Relay


SNO 4083KM Safety Relay Function - after the supply voltage is applied to terminals A1/A2 and the safety inputs are closed, the enabling current paths (NO contacts) are closed and the signal current path (NC contact) is opened automatically or by pressing the reset button (manual monitored start). When the safety inputs are opened/de-energized the enabling current paths (NO contacts) are opened immediately and the signal current path (NC contact) is closed.

The SNO 4083KM safety relay requires fewer connection cables, irrespective of whether operation with or without cross monitoring is desired. The two channel control of the SNO 4083KM is carried out by either an NC/NC or an NC/NO combination of the safety sensor. In the case of two channel control of the device, a synchronous time is automatically monitored between the two channels. The SafeStart function is used with a manual start, the reset input is automatically monitored for a rising and falling signal edge. The Monoflop function is integrated into the safety relay and prevents device interlocking under all circumstances. Simple diagnosis is possible thanks to an intelligent display system that shows the user the different operating modes of the safety relay in its different applications.

Monitoring of E-Stop, Safety Gate and Light Barrier applications

Stop Category 0 according to EN 60204-1

Single channel or two channel control

Two-channel control with NC/NC or NC/NO

Manual or automatic start

Cross monitoring

Synchronous time monitoring for two channel control

3 enabling current path / 1 signalling current path

Screw terminals, pluggable

Up to PL e / Category 4 (EN ISO 13849-1)

Up to SILCL 3 (EN 62061)