Wieland SNO 4083, 24V dc Safety Relay, 3 Safety Contacts, 1
- RS Stock No.:
- 780-5073
- Mfr. Part No.:
- R1.188.3580.0
- Manufacturer:
- Wieland
Subtotal (1 unit)*
PHP28,526.66
(exc. VAT)
PHP31,949.86
(inc. VAT)
FREE delivery for orders over ₱3,000.00
In Stock
- Plus 17 unit(s) shipping from April 27, 2026
- Plus 2 unit(s) shipping from May 04, 2026
- Plus 6 unit(s) shipping from May 14, 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per Unit |
|---|---|
| 1 + | PHP28,526.66 |
*price indicative
- RS Stock No.:
- 780-5073
- Mfr. Part No.:
- R1.188.3580.0
- Manufacturer:
- Wieland
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Wieland | |
| Product Type | Safety Relay | |
| Safety Contacts | 3 | |
| Contact Configuration | NOC | |
| Number of Auxiliary Contacts | 1 | |
| Reset Method | Manual | |
| Mount Type | DIN Rail | |
| Series | SNO 4083 | |
| Power Consumption | 1.6W | |
| Terminal Type | Screw | |
| Time Delay | 1.5 s | |
| IP Rating | IP40 | |
| Switching AC Voltage | 230V ac | |
| Switching DC Voltage | 24V dc | |
| Standards/Approvals | EN 50156-1, EN ISO 13849-1, EN 62061, EN 81-1 | |
| Contact Current | 6A | |
| Minimum Operating Temperature | -25°C | |
| Maximum Operating Temperature | 65°C | |
| Width | 22.5mm | |
| Height | 114mm | |
| Length | 96.5mm | |
| Hazardous Area Certification | No | |
| Safety Category | 4 | |
| Coil Voltage | 24V dc | |
| Select all | ||
|---|---|---|
Brand Wieland | ||
Product Type Safety Relay | ||
Safety Contacts 3 | ||
Contact Configuration NOC | ||
Number of Auxiliary Contacts 1 | ||
Reset Method Manual | ||
Mount Type DIN Rail | ||
Series SNO 4083 | ||
Power Consumption 1.6W | ||
Terminal Type Screw | ||
Time Delay 1.5 s | ||
IP Rating IP40 | ||
Switching AC Voltage 230V ac | ||
Switching DC Voltage 24V dc | ||
Standards/Approvals EN 50156-1, EN ISO 13849-1, EN 62061, EN 81-1 | ||
Contact Current 6A | ||
Minimum Operating Temperature -25°C | ||
Maximum Operating Temperature 65°C | ||
Width 22.5mm | ||
Height 114mm | ||
Length 96.5mm | ||
Hazardous Area Certification No | ||
Safety Category 4 | ||
Coil Voltage 24V dc | ||
- COO (Country of Origin):
- DE
Wieland SNO 4083KM Safety Relay
SNO 4083KM Safety Relay Function - after the supply voltage is applied to terminals A1/A2 and the safety inputs are closed, the enabling current paths (NO contacts) are closed and the signal current path (NC contact) is opened automatically or by pressing the reset button (manual monitored start). When the safety inputs are opened/de-energized the enabling current paths (NO contacts) are opened immediately and the signal current path (NC contact) is closed.
The SNO 4083KM safety relay requires fewer connection cables, irrespective of whether operation with or without cross monitoring is desired. The two channel control of the SNO 4083KM is carried out by either an NC/NC or an NC/NO combination of the safety sensor. In the case of two channel control of the device, a synchronous time is automatically monitored between the two channels. The SafeStart function is used with a manual start, the reset input is automatically monitored for a rising and falling signal edge. The Monoflop function is integrated into the safety relay and prevents device interlocking under all circumstances. Simple diagnosis is possible thanks to an intelligent display system that shows the user the different operating modes of the safety relay in its different applications.
Monitoring of E-Stop, Safety Gate and Light Barrier applications
Stop Category 0 according to EN 60204-1
Single channel or two channel control
Two-channel control with NC/NC or NC/NO
Manual or automatic start
Cross monitoring
Synchronous time monitoring for two channel control
3 enabling current path / 1 signalling current path
Screw terminals, pluggable
Up to PL e / Category 4 (EN ISO 13849-1)
Up to SILCL 3 (EN 62061)