Pilz P2HZ X1, 24V dc Safety Relay, 3 Safety Contacts, 1
- RS Stock No.:
- 239-1083
- Distrelec Article No.:
- 304-10-469
- Mfr. Part No.:
- 774340
- Manufacturer:
- Pilz
Bulk discount available
Subtotal (1 unit)*
PHP52,252.82
(exc. VAT)
PHP58,523.16
(inc. VAT)
FREE delivery for orders over ₱3,000.00
In Stock
- 10 unit(s) ready to ship from another location
- Plus 3 unit(s) shipping from May 05, 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per Unit |
|---|---|
| 1 - 4 | PHP52,252.82 |
| 5 + | PHP43,004.07 |
*price indicative
- RS Stock No.:
- 239-1083
- Distrelec Article No.:
- 304-10-469
- Mfr. Part No.:
- 774340
- Manufacturer:
- Pilz
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Pilz | |
| Product Type | Safety Relay | |
| Safety Contacts | 3 | |
| Contact Configuration | 3 NO/1 NC | |
| Number of Auxiliary Contacts | 1 | |
| Reset Method | Monitored | |
| Mount Type | DIN Rail | |
| Series | P2HZ X1 | |
| Power Consumption | 6VA | |
| Terminal Type | Screw | |
| IP Rating | IP40, IP20, IP54 | |
| Switching DC Voltage | 24V dc | |
| Switching AC Voltage | 240V ac | |
| Standards/Approvals | EN 60068-2-6, EN 60068-2-78, EN ISO 13849-1, EN 60947-1, EN 60947-4-1, EN 574 Type IIIC, EN 60204-1, EN IEC 62061, EN 60947-5-1, EN 61000-6-2, IEC 61511 | |
| Minimum Operating Temperature | -25°C | |
| Contact Current | 5A | |
| Maximum Operating Temperature | 55°C | |
| Length | 87mm | |
| Height | 121mm | |
| Width | 45mm | |
| Hazardous Area Certification | No | |
| Safety Category | CAT 4 | |
| Coil Voltage | 24V dc | |
| Select all | ||
|---|---|---|
Brand Pilz | ||
Product Type Safety Relay | ||
Safety Contacts 3 | ||
Contact Configuration 3 NO/1 NC | ||
Number of Auxiliary Contacts 1 | ||
Reset Method Monitored | ||
Mount Type DIN Rail | ||
Series P2HZ X1 | ||
Power Consumption 6VA | ||
Terminal Type Screw | ||
IP Rating IP40, IP20, IP54 | ||
Switching DC Voltage 24V dc | ||
Switching AC Voltage 240V ac | ||
Standards/Approvals EN 60068-2-6, EN 60068-2-78, EN ISO 13849-1, EN 60947-1, EN 60947-4-1, EN 574 Type IIIC, EN 60204-1, EN IEC 62061, EN 60947-5-1, EN 61000-6-2, IEC 61511 | ||
Minimum Operating Temperature -25°C | ||
Contact Current 5A | ||
Maximum Operating Temperature 55°C | ||
Length 87mm | ||
Height 121mm | ||
Width 45mm | ||
Hazardous Area Certification No | ||
Safety Category CAT 4 | ||
Coil Voltage 24V dc | ||
- COO (Country of Origin):
- FR

PILZ P2HZ X1, Two Hand Monitoring, Type IIIC
The P2HZ X1 series of Safety Relays by PILZ offer you affordable and reliable feedback control loops, specifically designed to handle the monitoring of your external relays or contactors.
Features and benefits
• Specially designed for two handed control/operation. The P2HZ series will not function unless the operator has their hands outside the danger zone area during hazardous movement.
• LED indicator for switching your channel status from 1 to 2 and also to monitor your supply voltage
• Single or Dual channel input operation (Single channel are used more beneficially with smaller type machines where you need to use a dedicated logic device that only has a small function to cut off in an emergency – Dual allows you to take control of more safety circuits and control a greater amount of control zones at any given time)
• Reactivation: The outputs will no re-energise unless both operator elements have been released and then re-operated simultaneously.
• Suitable for DIN rail mounting
• Durable and has an extended service life vs. competitors
Safety features
• The relay will provide the circuit self-monitoring.
• The safety functions of the device remain in effect even in the case of component failures.
• The relay will prevent the circuit from further press strokes in the case of, relay failures, contact welding, coil defects or open/short circuits.
Applications
• Mechanical presses
• Hydraulic presses
• General safety circuits (in accordance with EN 60204-1)
Technical safety parameters
• EN 60204-1
• EN 954-1
• EN (IEC) 62061
• EN ISO 13849-1
• IEC 61511 – SIL 3
Standards
EN574 (type III C)