Omron G9SX-SM, 24V dc Safety Relay, 1 Safety Contacts, 2
- RS Stock No.:
- 214-6825
- Mfr. Part No.:
- G9SX-SM032-RC
- Manufacturer:
- Omron
Subtotal (1 unit)*
PHP61,032.21
(exc. VAT)
PHP68,356.08
(inc. VAT)
FREE delivery for orders over ₱5,000.00
Temporarily out of stock
- Shipping from January 11, 2027
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per Unit |
|---|---|
| 1 + | PHP61,032.21 |
*price indicative
- RS Stock No.:
- 214-6825
- Mfr. Part No.:
- G9SX-SM032-RC
- Manufacturer:
- Omron
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Omron | |
| Product Type | Safety Relay | |
| Safety Contacts | 1 | |
| Contact Configuration | 3PST | |
| Number of Auxiliary Contacts | 2 | |
| Mount Type | PCB | |
| Reset Method | Automatic | |
| Series | G9SX-SM | |
| IP Rating | IP20, IP40 | |
| Switching AC Voltage | 415V ac | |
| Minimum Operating Temperature | -10°C | |
| Standards/Approvals | EN 954-1 | |
| Maximum Operating Temperature | 55°C | |
| Hazardous Area Certification | No | |
| Safety Category | 4 | |
| Coil Voltage | 24V dc | |
| Select all | ||
|---|---|---|
Brand Omron | ||
Product Type Safety Relay | ||
Safety Contacts 1 | ||
Contact Configuration 3PST | ||
Number of Auxiliary Contacts 2 | ||
Mount Type PCB | ||
Reset Method Automatic | ||
Series G9SX-SM | ||
IP Rating IP20, IP40 | ||
Switching AC Voltage 415V ac | ||
Minimum Operating Temperature -10°C | ||
Standards/Approvals EN 954-1 | ||
Maximum Operating Temperature 55°C | ||
Hazardous Area Certification No | ||
Safety Category 4 | ||
Coil Voltage 24V dc | ||
Omron G9SX-SM Series Safety Relay, 24V DC Coil Voltage, IP20/IP40 Ingress Protection - G9SX-SM032-RC
This safety relay provides a compact electronic safety interface for machine control circuits, designed for printed circuit board mounting and intended to safeguard equipment in industrial settings. It combines a single dedicated safety contact with supplementary switching and auxiliary functions to manage safety-related stop and monitoring tasks across a defined temperature range.
Features and Benefits:
• 24V DC coil input enabling straightforward control integration
• Three-pole changeover contact configuration for versatile switching
• Two auxiliary contacts offering additional signalling capabilities
• 415V AC switching capability to handle higher voltage circuits
• EN954-1 Category4 safety classification for high-integrity applications
• Automatic reset mode to resume operation without manual intervention
• Three-pole changeover contact configuration for versatile switching
• Two auxiliary contacts offering additional signalling capabilities
• 415V AC switching capability to handle higher voltage circuits
• EN954-1 Category4 safety classification for high-integrity applications
• Automatic reset mode to resume operation without manual intervention
Applications
• Suitable for machine safety stop circuit implementations
• Ideal for integration onto PCBs in control cabinets
• Used for interfacing emergency‑stop monitoring systems
• Can be used for guarding and interlock safety circuits
• Useful in systems requiring auxiliary signal feedback
• Ideal for integration onto PCBs in control cabinets
• Used for interfacing emergency‑stop monitoring systems
• Can be used for guarding and interlock safety circuits
• Useful in systems requiring auxiliary signal feedback
What ambient temperatures can it withstand during operation?
It operates reliably between -10°C and +55°C, allowing use in standard industrial environments.
How is the unit protected against ingress during installation?
It carries ratings of IP20 and IP40, indicating protection suitable for enclosed assemblies and limited external exposure.
How many safety-level switching elements are provided?
There is one designated safety contact for safety-related switching functions alongside additional auxiliary contacts.
Is it certified for hazardous-area installation?
No hazardous‑area certification is provided, so it is not intended for classified explosive atmospheres.