Schneider Electric Preventa, 24V ac/dc Safety Relay, 5 Safety Contacts, 4
- RS Stock No.:
- 201-1482
- Mfr. Part No.:
- XPSUAK12AC
- Manufacturer:
- Schneider Electric
Subtotal (1 unit)*
PHP13,571.85
(exc. VAT)
PHP15,200.47
(inc. VAT)
FREE delivery for orders over ₱5,000.00
Stocked by manufacturer
- Ready to ship from October 19, 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per Unit |
|---|---|
| 1 + | PHP13,571.85 |
*price indicative
- RS Stock No.:
- 201-1482
- Mfr. Part No.:
- XPSUAK12AC
- Manufacturer:
- Schneider Electric
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Schneider Electric | |
| Product Type | Safety Relay | |
| Safety Contacts | 5 | |
| Contact Configuration | 2 NC | |
| Number of Auxiliary Contacts | 4 | |
| Mount Type | DIN Rail | |
| Series | Preventa | |
| Power Consumption | 4.5W | |
| Terminal Type | Spring Terminal | |
| IP Rating | IP20 | |
| Switching DC Voltage | 250V dc | |
| Switching AC Voltage | 250V ac | |
| Standards/Approvals | RoHS | |
| Contact Current | 5A | |
| Minimum Operating Temperature | -25°C | |
| Maximum Operating Temperature | 55°C | |
| Width | 22.5mm | |
| Length | 100mm | |
| Height | 120mm | |
| Hazardous Area Certification | No | |
| Safety Category | PLe Category 4 | |
| Coil Voltage | 24V ac/dc | |
| Select all | ||
|---|---|---|
Brand Schneider Electric | ||
Product Type Safety Relay | ||
Safety Contacts 5 | ||
Contact Configuration 2 NC | ||
Number of Auxiliary Contacts 4 | ||
Mount Type DIN Rail | ||
Series Preventa | ||
Power Consumption 4.5W | ||
Terminal Type Spring Terminal | ||
IP Rating IP20 | ||
Switching DC Voltage 250V dc | ||
Switching AC Voltage 250V ac | ||
Standards/Approvals RoHS | ||
Contact Current 5A | ||
Minimum Operating Temperature -25°C | ||
Maximum Operating Temperature 55°C | ||
Width 22.5mm | ||
Length 100mm | ||
Height 120mm | ||
Hazardous Area Certification No | ||
Safety Category PLe Category 4 | ||
Coil Voltage 24V ac/dc | ||
- COO (Country of Origin):
- ID
Schneider Electric Preventa Range of Safety Relays - XPS Universal Range
The XPSUAK range of safety relay modules is used for providing protection for both the user and the machine through immediately stopping the dangerous movement when instructed to do so from the user or if there is the detection of a problem within the safety circuit. These types of safety relays are predominantly used for monitoring applications such as:
• Monitoring Emergency stop circuits
• Switches activated by protection devices
• Mechanical guard switches
• Magnetic switch with antivalent or 2 NC contacts
• Proximity safety switch with antivalent contacts
• Sensor Pair
• 1 PNP + NPN sensor
• RFID safety switch
• Type 4 light curtains
• 4-wire sensing mats or edges
Features & Benefits
• Functions can be configured by selector switches on the front face
• A solid-state diagnostic output with complete status information facilitates maintenance
• To monitor a higher number of antivalent contacts using this safety module, the antivalent contacts can be connected with a NC in series and NO in parallel
• 6 LEDs on the front face provide information on the monitoring circuit status
• 20 terminals with a safe expansion connection
• Removable terminal blocks for the connection type
• Automatic, manual and monitored starts
• 2 safety inputs with 2 NO + 1 NO outputs
• The control outputs are 3NO/OFF - configurable pulsed outputs
Schneider Electric Preventa Safety Module - XPSUAK12AC
• Safety levels for the relay include: Can reach PL e/category 4 for normally open relay contact conforming to ISO 13849-1, Can reach SILCL 3 for normally open relay contact conforming to IEC 62061, Can reach SIL 3 for normally open relay contact conforming to IEC 61508, Can reach PL c/category 1 for normally closed relay contact conforming to ISO 13849-1, Can reach SILCL 1 for normally closed relay contact conforming to IEC 62061 and Can reach SIL 1 for normally closed relay contact conforming to IEC 61508
• NC pair, PNP pair, Antivalent pair and OSSD pair electrical circuit type
• Forms part of the preventa safety automation range of products
• This relay has a rated supply voltage of 24 V AC - 15...10 % and 24 V DC - 20...20 %
• The device has an internal and electronic input protection type
• Associated fuse rating: 10A gG for NO relay output circuit
• Conventional free air thermal current: 8A
• Maximum line resistance: 600
Related links
- Schneider Electric Preventa 5 Safety Contacts, 4
- Schneider Electric Preventa 5 Safety Contacts
- Schneider Electric Preventa 5 Safety Contacts, 8
- Schneider Electric Preventa 3 Safety Contacts, 4
- Schneider Electric Preventa 48 V ac/dc Safety Relay 4
- Schneider Electric Preventa 2 Safety Contacts
- Schneider Electric Preventa 2 Safety Contacts, 8
- Schneider Electric Preventa 3 Safety Contacts, 8