SICK RLY3, 24V dc Safety Relay, 2 Safety Contacts

Subtotal (1 unit)*

PHP27,437.23

(exc. VAT)

PHP30,729.70

(inc. VAT)

Add to Basket
Select or type quantity
In Stock
  • 2 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per Unit
1 +PHP27,437.23

*price indicative

RS Stock No.:
180-6092
Mfr. Part No.:
RLY3-HAND1
Manufacturer:
SICK
Find similar products by selecting one or more attributes.
Select all

Brand

SICK

Product Type

Safety Relay

Safety Contacts

2

Series

RLY3

Power Consumption

1.3W

Terminal Type

Plug-In

IP Rating

IP20

Time Delay

500 ms

Standards/Approvals

IEC 61508, IEC 62061, EN ISO 13849, EN 60529, EN 60664-1

Contact Current

6A

Switching DC Voltage

250V dc

Width

18mm

Height

124.60mm

Length

85.5mm

Hazardous Area Certification

No

Safety Category

EN ISO 13849, CAT 4

Coil Voltage

24V dc

COO (Country of Origin):
HU

SICK RLY3 Series Safety Relay, 24V dc Coil voltage, 6A Contact Current - RLY3-HAND1


This safety relay is designed to provide functional safety switching for control and protection systems in industrial settings. It operates from a 24V dc Coil and offers timed response for safety-related control sequences. The module is intended for panel or DIN-rail mounted installations where compact, application-focused safety switching is required and is suitable for environments not exposed to hazardous-area certification requirements.

Features and Benefits:


• 2 safety contacts for controlled interruption of safety circuits
• 500 MS time delay enabling sequenced shutdowns or restart logic
• 6A contact current supporting moderate load switching requirements
• 1.3 W power consumption reducing control-circuit energy draw
• Plug-in Terminal type for straightforward replacement and wiring

Applications


• Suitable for integration into machine safety circuits
• Used with safety interlocks and guarded access systems
• Ideal for functional safety control panels in manufacturing
• Can be used for sequenced stop functions in automation

What level of safety category does it meet?


It complies with EN ISO 13849 CAT 4 for high-integrity safety applications.

Which international functional-safety standards apply?


It is certified to IEC 61508 and IEC 62061 for functional safety requirements.

What environmental protection does the enclosure provide?


The unit has an IP20 rating, providing protection against solid objects larger than 12 mm and no protection against liquids.

Is it suitable for applications requiring hazardous-area approval?


It does not carry hazardous-area certification and should not be specified where such approval is mandatory.

Related links

Be the first to know about our latest products and offers

Email address

The personal information you provide to us when signing up to this mailing list will be processed in line with the Privacy Policy