Banner UM, 24V ac Safety Relay, 2 Safety Contacts, 1
- RS Stock No.:
- 285-902
- Mfr. Part No.:
- UM-FA-11A
- Manufacturer:
- Banner
Subtotal (1 unit)*
PHP18,368.23
(exc. VAT)
PHP20,572.42
(inc. VAT)
Stock information currently inaccessible - Please check back later
Units | Per Unit |
|---|---|
| 1 + | PHP18,368.23 |
*price indicative
- RS Stock No.:
- 285-902
- Mfr. Part No.:
- UM-FA-11A
- Manufacturer:
- Banner
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Banner | |
| Product Type | Safety Relay | |
| Safety Contacts | 2 | |
| Number of Auxiliary Contacts | 1 | |
| Reset Method | Automatic or Manual | |
| Mount Type | DIN Rail | |
| Series | UM | |
| Power Consumption | 2W | |
| Terminal Type | Screw | |
| IP Rating | IP20 | |
| Standards/Approvals | IEC 61508 IEC 62061 | |
| Contact Current | 7A | |
| Minimum Operating Temperature | 0°C | |
| Switching AC Voltage | 250V ac | |
| Switching DC Voltage | 250V dc | |
| Maximum Operating Temperature | 50°C | |
| Height | 84mm | |
| Width | 22.5mm | |
| Length | 118mm | |
| Hazardous Area Certification | No | |
| Safety Category | 4 | |
| Coil Voltage | 24V ac | |
| Select all | ||
|---|---|---|
Brand Banner | ||
Product Type Safety Relay | ||
Safety Contacts 2 | ||
Number of Auxiliary Contacts 1 | ||
Reset Method Automatic or Manual | ||
Mount Type DIN Rail | ||
Series UM | ||
Power Consumption 2W | ||
Terminal Type Screw | ||
IP Rating IP20 | ||
Standards/Approvals IEC 61508 IEC 62061 | ||
Contact Current 7A | ||
Minimum Operating Temperature 0°C | ||
Switching AC Voltage 250V ac | ||
Switching DC Voltage 250V dc | ||
Maximum Operating Temperature 50°C | ||
Height 84mm | ||
Width 22.5mm | ||
Length 118mm | ||
Hazardous Area Certification No | ||
Safety Category 4 | ||
Coil Voltage 24V ac | ||
- COO (Country of Origin):
- US
The Banner Universal Input Safety Module is a versatile safety device that can monitor a wide range of safety and non-safety input devices. It is designed to integrate with various safety and control systems to ensure that all devices operate within safe parameters, offering flexibility in the types of devices it can support and the configurations it allows.
Safety Integrity Level SIL 3 per IEC 61508/IEC 62061