SICK i10 Safety Interlock Switch, Electromagnetic, Fibreglass Reinforced Thermoplastic, Electromagnetic
- RS Stock No.:
- 285-9558
- Mfr. Part No.:
- i10-E0233 Lock
- Manufacturer:
- SICK
Subtotal (1 unit)*
PHP26,523.95
(exc. VAT)
PHP29,706.82
(inc. VAT)
FREE delivery for orders over ₱3,000.00
Stocked by manufacturer
- Ready to ship from November 25, 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per Unit |
|---|---|
| 1 + | PHP26,523.95 |
*price indicative
- RS Stock No.:
- 285-9558
- Mfr. Part No.:
- i10-E0233 Lock
- Manufacturer:
- SICK
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | SICK | |
| Lock Style | Electromagnetic | |
| Product Type | Safety Interlock Switch | |
| Lock Type | Electromagnetic | |
| Actuator Included | No | |
| Safety Contacts | 2 NC | |
| Housing Material | Fibreglass Reinforced Thermoplastic | |
| Series | i10 | |
| IP Rating | IP67 | |
| Contact AC Voltage | 230V ac | |
| Contact DC Voltage | 24V dc | |
| Minimum Operating Temperature | -20°C | |
| Switch Contact Current | 4A | |
| Maximum Operating Temperature | 55°C | |
| Hazardous Area Certification | No | |
| Depth | 40mm | |
| Length | 192mm | |
| Width | 42mm | |
| Standards/Approvals | CE | |
| Number of Head Directions | 4 | |
| Conduit Entry | M20 | |
| Select all | ||
|---|---|---|
Brand SICK | ||
Lock Style Electromagnetic | ||
Product Type Safety Interlock Switch | ||
Lock Type Electromagnetic | ||
Actuator Included No | ||
Safety Contacts 2 NC | ||
Housing Material Fibreglass Reinforced Thermoplastic | ||
Series i10 | ||
IP Rating IP67 | ||
Contact AC Voltage 230V ac | ||
Contact DC Voltage 24V dc | ||
Minimum Operating Temperature -20°C | ||
Switch Contact Current 4A | ||
Maximum Operating Temperature 55°C | ||
Hazardous Area Certification No | ||
Depth 40mm | ||
Length 192mm | ||
Width 42mm | ||
Standards/Approvals CE | ||
Number of Head Directions 4 | ||
Conduit Entry M20 | ||
- COO (Country of Origin):
- DE
SICK i10 Series Safety Interlock Switch, IP67, 230V AC Contact Voltage - i10-E0233 Lock
This safety interlock switch provides secure door and guard monitoring for industrial machinery, combining an electromagnetic locking mechanism with a robust housing for use in automated environments. Intended for control panels and access points, it integrates into safety circuits to help manage authorised access and prevent unintended operation.
Features and Benefits:
• Electromagnetic lock style ensures controlled access with holding force
• Fibreglass reinforced thermoplastic housing resists chemical and impact
• IP67 rating allows dust-tight and temporary immersion protection
• Two NC safety contacts provide straightforward circuit interruption
• Accepts M20 conduit entry for standardised cable routing
• Operates between -20°C and 55°C for varied ambient conditions
• Fibreglass reinforced thermoplastic housing resists chemical and impact
• IP67 rating allows dust-tight and temporary immersion protection
• Two NC safety contacts provide straightforward circuit interruption
• Accepts M20 conduit entry for standardised cable routing
• Operates between -20°C and 55°C for varied ambient conditions
Applications
• Suitable for guarding access on automated assembly lines
• Ideal for machine enclosures requiring monitored locking
• Used with safety relays to protect maintenance personnel
• Can be used for interlocking doors in packaging machinery
• Ideal for machine enclosures requiring monitored locking
• Used with safety relays to protect maintenance personnel
• Can be used for interlocking doors in packaging machinery
What electrical voltages does it support?
It switches AC up to 230V and DC at 24V for integration with common control systems.
How many actuation orientations are available?
The head can be positioned in four directions to accommodate different mounting arrangements.
What current rating should be considered when wiring?
The contacts are rated to carry 4A, so wiring and upstream protection should match this load.
What approvals and environmental ratings apply?
It carries CE marking and its enclosure meets IP67 ingress protection for dust and immersion.
Is an actuator supplied with the unit?
No actuator is included, so a compatible actuator must be selected separately for the installation.
Related links
- SICK i10 Safety Interlock Switch Fibreglass Reinforced Thermoplastic, Electromagnetic
- SICK i14 Safety Interlock Switch Fibreglass Reinforced Thermoplastic, Electromagnetic
- SICK i110 Safety Interlock Switch Fibreglass Reinforced Thermoplastic, Electromagnetic
- SICK i10 Safety Switch Fibreglass Reinforced Thermoplastic
- SICK i10 Safety Switch Fibreglass Reinforced Thermoplastic, Power to Release
- SICK i10 Safety Interlock Switch, Fibreglass Reinforced Thermoplastic
- SICK I15 Safety Switch Fibreglass Reinforced Thermoplastic
- SICK I15 Safety Switch Fibreglass Reinforced Thermoplastic, i15 Lock