SICK RE27 Safety Switch, Vistal, Magnet

Supply shortage
Due to a global supply shortage, we don't know when this will be back in stock.
RS Stock No.:
285-2283
Mfr. Part No.:
RE27-SB68LS04
Manufacturer:
SICK
Find similar products by selecting one or more attributes.
Select all

Brand

SICK

Product Type

Safety Switch

Lock Type

Magnet

Actuator Included

No

Housing Material

Vistal

Series

RE27

Contact DC Voltage

24V dc

Contact AC Voltage

230V ac

IP Rating

IP67

Minimum Operating Temperature

-30°C

Hazardous Area Certification

No

Maximum Operating Temperature

60°C

Length

88mm

Number of Head Directions

3

Depth

25mm

Width

13mm

Standards/Approvals

CE

COO (Country of Origin):
MY

Overview


RE2 magnetic safety switches are equipped with either complementary NC/NO contacts or equivalent N/O contacts which are addressed directly with coded magnetic actuators. Magnetic safety switches are used in areas where a high level of contamination occurs.

They are simple to clean, thereby enabling high standards of hygiene. Their principle of operation enables greater tolerances, making them ideal for applications where precise guidance of the protective device is difficult.

At a glance


Response range of up to 9 mm

2 or 3 contacts

Up to performance level PL e / Cat. 4 (EN ISO 13849)

Sensors with plug connector or connected cable

LED status indicator (RE27)

Flexi Loop-compatible M12 plug connector (depending on variant)

Your Benefit


Long service life due to durable and low-maintenance design

Just one safety switch in conjunction with a suitable safety module makes it possible to solve applications up to PL e and Cat. 4 (EN ISO 13849)

High level of machine availability due to high tolerances for door misalignment

The devices are easy to clean, making them suitable for contaminated areas or environments with strict hygiene standards

Fast diagnostics via LED status indicator (RE27)

Flexi Loop now enables a safe series connection with enhanced diagnostics capabilities and minimal wiring effort.

Applications


Fields of applications

Monitoring of safety doors and removable guards

Applications requiring a high standard of hygiene

Applications where precise guidance of the safety door is not possible