Siemens SENTRON Series Residual Current Circuit Breaker, 25 A, 2-Pole, 300 mA, Type F, 10 kA 400 V ac
- RS Stock No.:
- 211-9670
- Mfr. Part No.:
- 5SV3612-3
- Manufacturer:
- Siemens
Subtotal (1 unit)*
PHP11,801.73
(exc. VAT)
PHP13,217.94
(inc. VAT)
Stock information currently inaccessible - Please check back later
Units | Per Unit |
|---|---|
| 1 + | PHP11,801.73 |
*price indicative
- RS Stock No.:
- 211-9670
- Mfr. Part No.:
- 5SV3612-3
- Manufacturer:
- Siemens
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Siemens | |
| Product Type | Residual Current Circuit Breaker | |
| Current Rating | 25 A | |
| Number of Poles | 2 | |
| Range | SENTRON | |
| Series | SENTRON | |
| Trip Sensitivity | 300mA | |
| Tripping Characteristics | Type F | |
| Mount Type | DIN Rail | |
| Standards/Approvals | VDE, CE, EAC, UKCA | |
| Terminal Type | Screw | |
| Depth | 70mm | |
| Height | 90mm | |
| Width | 36 mm | |
| Breaking Capacity | 10kA | |
| Earth Leakage Protection Type | Type A | |
| Break Time | Short | |
| Rated AC Voltage | 400 V ac | |
| Reset Actuator Type | Toggle Switch | |
| Tripping Mechanism | Electromagnetic | |
| Select all | ||
|---|---|---|
Brand Siemens | ||
Product Type Residual Current Circuit Breaker | ||
Current Rating 25 A | ||
Number of Poles 2 | ||
Range SENTRON | ||
Series SENTRON | ||
Trip Sensitivity 300mA | ||
Tripping Characteristics Type F | ||
Mount Type DIN Rail | ||
Standards/Approvals VDE, CE, EAC, UKCA | ||
Terminal Type Screw | ||
Depth 70mm | ||
Height 90mm | ||
Width 36 mm | ||
Breaking Capacity 10kA | ||
Earth Leakage Protection Type Type A | ||
Break Time Short | ||
Rated AC Voltage 400 V ac | ||
Reset Actuator Type Toggle Switch | ||
Tripping Mechanism Electromagnetic | ||
- COO (Country of Origin):
- DE
The Siemens Residual current operated circuit breaker has 2-pole and type Operating current is 25 A and trippening current 300 mA. Supply voltage is 230 These can generate residual currents at the output side, caused by a mixture of frequencies with frequency components in the kilohertz range. RCCBs, type F are best suited for this purpose, since they expand the range of functions offered by type A. They have an impulse withstand strength of > 3 kA and a current carrying capacity of up to 10 mA with smooth DC residual currents. Siemens offers a comprehensive portfolio of protection, switching, measuring and monitoring devices, distribution systems as well as switches and sockets for safe and efficient electrical infrastructure in buildings and industry.