Siemens SENTRON Series Residual Current Circuit Breaker, 40 A, 4-Pole, 30 mA, Type A, 10 kA 400 V ac
- RS Stock No.:
- 211-9643
- Mfr. Part No.:
- 5SV3344-6KK03
- Manufacturer:
- Siemens
Subtotal (1 unit)*
PHP33,287.77
(exc. VAT)
PHP37,282.30
(inc. VAT)
Stock information currently inaccessible - Please check back later
Units | Per Unit |
|---|---|
| 1 + | PHP33,287.77 |
*price indicative
- RS Stock No.:
- 211-9643
- Mfr. Part No.:
- 5SV3344-6KK03
- Manufacturer:
- Siemens
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Siemens | |
| Product Type | Residual Current Circuit Breaker | |
| Current Rating | 40 A | |
| Number of Poles | 4 | |
| Series | SENTRON | |
| Range | SENTRON | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type A | |
| Mount Type | DIN Rail | |
| Terminal Type | Screw | |
| Standards/Approvals | UKCA, VDE, EAC, CE | |
| Width | 72 mm | |
| Depth | 70mm | |
| Height | 90mm | |
| Breaking Capacity | 10kA | |
| Reset Actuator Type | Toggle Switch | |
| Rated AC Voltage | 400 V ac | |
| Tripping Mechanism | Electromagnetic | |
| Break Time | Short | |
| Earth Leakage Protection Type | Type A | |
| Select all | ||
|---|---|---|
Brand Siemens | ||
Product Type Residual Current Circuit Breaker | ||
Current Rating 40 A | ||
Number of Poles 4 | ||
Series SENTRON | ||
Range SENTRON | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type A | ||
Mount Type DIN Rail | ||
Terminal Type Screw | ||
Standards/Approvals UKCA, VDE, EAC, CE | ||
Width 72 mm | ||
Depth 70mm | ||
Height 90mm | ||
Breaking Capacity 10kA | ||
Reset Actuator Type Toggle Switch | ||
Rated AC Voltage 400 V ac | ||
Tripping Mechanism Electromagnetic | ||
Break Time Short | ||
Earth Leakage Protection Type Type A | ||
- COO (Country of Origin):
- DE
The Siemens Residual current operated circuit breaker has 4-pole and type A.Operating current is 40 A and trippening residual current 30 mA. Supply voltage is 400V. RCD is the residual current device for touch protection RCCBs, type A trip with both sinusoidal alternating currents (type AC) and pulsating DC residual currents. They are used mainly with single-phase consumers with electrical components in the supply unit, e.g. in residential and functional structures. Siemens offers a comprehensive portfolio of protection, switching, measuring and monitoring devices, distribution systems as well as switches and sockets for safe and efficient electrical infrastructure in buildings and industry.
Protection class IP IP20 if the distribution board is installed, with connected conductors
Silicon- free