ABB F200 Series Residual Current Circuit Breaker, 63 A, 4-Pole, 30 mA, Type F, 1 kA 400 V ac
- RS Stock No.:
- 176-9637
- Mfr. Part No.:
- 2CSF204325R1630 F204 F-63/0,03
- Manufacturer:
- ABB
Subtotal (1 unit)*
PHP88,078.93
(exc. VAT)
PHP98,648.40
(inc. VAT)
FREE delivery for orders over ₱3,000.00
Temporarily out of stock
- Shipping from July 06, 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per Unit |
|---|---|
| 1 + | PHP88,078.93 |
*price indicative
- RS Stock No.:
- 176-9637
- Mfr. Part No.:
- 2CSF204325R1630 F204 F-63/0,03
- Manufacturer:
- ABB
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | ABB | |
| Product Type | Residual Current Circuit Breaker | |
| Current Rating | 63 A | |
| Number of Poles | 4 | |
| Series | F200 | |
| Range | F200 | |
| Trip Sensitivity | 30mA | |
| Mount Type | DIN Rail | |
| Tripping Characteristics | Type F | |
| Standards/Approvals | CE, IEC EN 61008, RoHS | |
| Terminal Type | Screw | |
| Height | 85mm | |
| Width | 70 mm | |
| Depth | 69mm | |
| Breaking Capacity | 1kA | |
| Tripping Mechanism | Electromagnetic | |
| Reset Actuator Type | Toggle Switch | |
| Earth Leakage Protection Type | A-APR | |
| Rated AC Voltage | 400 V ac | |
| Select all | ||
|---|---|---|
Brand ABB | ||
Product Type Residual Current Circuit Breaker | ||
Current Rating 63 A | ||
Number of Poles 4 | ||
Series F200 | ||
Range F200 | ||
Trip Sensitivity 30mA | ||
Mount Type DIN Rail | ||
Tripping Characteristics Type F | ||
Standards/Approvals CE, IEC EN 61008, RoHS | ||
Terminal Type Screw | ||
Height 85mm | ||
Width 70 mm | ||
Depth 69mm | ||
Breaking Capacity 1kA | ||
Tripping Mechanism Electromagnetic | ||
Reset Actuator Type Toggle Switch | ||
Earth Leakage Protection Type A-APR | ||
Rated AC Voltage 400 V ac | ||
- COO (Country of Origin):
- IT
F204 Type F, RCCB in four poles with rated current 25-40-63A and sensitivity 30mA for the protection of more than one single phase circuit with a single device.
Type F features at a glance:
Type F RCDs offer the same range of protection and functionality as an RCD Type A APR; this means that they detect sinusoidal AC currents as well as pulsating DC currents. In addition to this, they are also tested according to IEC/EN 62423 which foresees the application of a simulated multi-frequency residual current with appropriate coefficient associated to the each level of frequency up to 1kHz.
The intervention characteristic has a short-time delayed which prevents unwanted tripping in case pulsed leakage currents of up to ten milliseconds occur at activation of filters.
The RCDs Type F have a surge current withstand capacity of more than 3kA and can accept superimposed smooth DC residual currents of up to 10mA without affecting their standard functionality.