Schneider Electric Residual Current Circuit Breaker with Overload Protection, 32 A Current Rating, 3-Pole, 30 mA Trip
- RS Stock No.:
- 239-9968
- Mfr. Part No.:
- A9DX3732
- Manufacturer:
- Schneider Electric
Subtotal (1 unit)*
PHP54,140.82
(exc. VAT)
PHP60,637.72
(inc. VAT)
FREE delivery for orders over ₱3,000.00
In Stock
- Plus 1 unit(s) shipping from March 23, 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per Unit |
|---|---|
| 1 + | PHP54,140.82 |
*price indicative
Better World
Our Better World range features products that make it easy for you to make a greener product choice you can trust. Click here to find out more.
- RS Stock No.:
- 239-9968
- Mfr. Part No.:
- A9DX3732
- Manufacturer:
- Schneider Electric
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Schneider Electric | |
| Current Rating | 32 A | |
| Product Type | Residual Current Circuit Breaker with Overload Protection | |
| Series | Acti9 iDT40 | |
| Range | Acti9 | |
| Number of Poles | 3 | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type C | |
| Mount Type | DIN Rail | |
| Terminal Type | Tunnel | |
| Earth Leakage Protection Type | A-SI | |
| Depth | 75mm | |
| Height | 93mm | |
| Width | 36 mm | |
| Better World Product | Yes | |
| Reset Actuator Type | Lever | |
| Breaking Capacity | 10kA | |
| Application | Distribution | |
| Tripping Mechanism | Thermal Magnetic | |
| Standards/Approvals | CE, IEC, RoHS | |
| Select all | ||
|---|---|---|
Brand Schneider Electric | ||
Current Rating 32 A | ||
Product Type Residual Current Circuit Breaker with Overload Protection | ||
Series Acti9 iDT40 | ||
Range Acti9 | ||
Number of Poles 3 | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type C | ||
Mount Type DIN Rail | ||
Terminal Type Tunnel | ||
Earth Leakage Protection Type A-SI | ||
Depth 75mm | ||
Height 93mm | ||
Width 36 mm | ||
Better World Product Yes | ||
Reset Actuator Type Lever | ||
Breaking Capacity 10kA | ||
Application Distribution | ||
Tripping Mechanism Thermal Magnetic | ||
Standards/Approvals CE, IEC, RoHS | ||
- COO (Country of Origin):
- ES
Schneider Electric Acti9 iDD40N Series RCBO, 32A Current Rating, 3P+N Poles - A9DX3732
This residual current circuit breaker with overcurrent protection (RCBO) is designed for effective current distribution. With a current rating of 32A and a tripping sensitivity of 30 mA, this device is essential for safeguarding electrical systems. The compact design measures 108mm in length, 91mm in width, and 73mm in depth, facilitating easy installation on DIN rail systems.
Features & Benefits
• Provides instantaneous earth leakage protection for safety
• Built with thermal-magnetic technology for accurate tripping
• High breaking capacity of 10kA to handle fault conditions
• Suitable for isolation and compliant with IEC standards
• Compact design compatible with various distribution blocks
• Features an easy-to-read ON/OFF indication and trip indicator
Applications
• Used in residential and commercial distribution boards
• Ideal for protecting critical circuits in industrial environments
• Suitable for systems requiring Type A-SI earth leakage functions
• Utilised in electrical installations where safety is paramount
How does the device ensure effective earth leakage protection?
The RCBO utilises a sensitivity of 30 mA to quickly detect and disconnect faulty circuits, reducing the risk of electric shocks or fire hazards.
What type of mounting method does this product support?
It is designed for DIN rail mounting, allowing for quick and efficient installation within various electrical enclosures.
What is the maximum network voltage support for this device?
It supports a rated operational voltage of 400V AC at a frequency of 50 Hz, making it compatible with common power supply systems.
How does the thermal-magnetic tripping technology enhance performance?
This technology offers reliable protection against both overloads and short circuits, automatically disconnecting the circuit in the event of unsafe conditions.
What is the significance of its breaking capacity?
With a breaking capacity of 10kA, it can effectively manage unforeseen electrical faults, ensuring greater safety and system integrity.
Related links
- Schneider Electric Residual Current Circuit Breaker with Overload Protection 3-Pole, 30 mA Trip
- Schneider Electric Residual Current Circuit Breaker with Overload Protection 3-Pole, 30 mA Trip
- Schneider Electric Residual Current Circuit Breaker with Overload Protection 3-Pole, 30 mA Trip
- Schneider Electric Residual Current Circuit Breaker with Overload Protection 3-Pole, 30 mA Trip
- Schneider Electric Residual Current Circuit Breaker with Overload Protection 3-Pole, 30 mA Trip
- Schneider Electric Residual Current Circuit Breaker with Overload Protection 1-Pole, 30 mA Trip
- Schneider Electric Residual Current Circuit Breaker with Overload Protection 1-Pole, 30 mA Trip
- Schneider Electric Residual Current Circuit Breaker with Overload Protection 4-Pole, 30 mA Trip