Myrra 6 to 24 V 2 Output PCB PCB Transformer, EN 60950, EN 61558-2-6, UL 5085 1.8 VA
- RS Stock No.:
- 173-9721
- Mfr. Part No.:
- 44128
- Manufacturer:
- Myrra
Bulk discount available
Subtotal (1 unit)*
PHP302.62
(exc. VAT)
PHP338.93
(inc. VAT)
FREE delivery for orders over ₱3,000.00
In Stock
- 11 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per Unit |
|---|---|
| 1 - 24 | PHP302.62 |
| 25 - 49 | PHP293.54 |
| 50 - 99 | PHP284.74 |
| 100 - 249 | PHP278.42 |
| 250 + | PHP272.38 |
*price indicative
- RS Stock No.:
- 173-9721
- Mfr. Part No.:
- 44128
- Manufacturer:
- Myrra
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Myrra | |
| Product Type | PCB Transformer | |
| Secondary Voltage | 6 to 24 V | |
| Primary Voltage | 117 to 230 V | |
| Number of Outputs | 2 | |
| Length | 32.6mm | |
| Width | 27.6 mm | |
| Power | 1.8VA | |
| Depth | 27.3mm | |
| Weight | 40g | |
| Mount Type | PCB | |
| Isolation Voltage | 4kV | |
| Maximum Operating Temperature | 250°C | |
| Minimum Operating Frequency | 50Hz | |
| Series | 44000 | |
| Maximum Operating Frequency | 60Hz | |
| Standards/Approvals | EN 60950, EN 61558-2-6, UL 5085 | |
| Select all | ||
|---|---|---|
Brand Myrra | ||
Product Type PCB Transformer | ||
Secondary Voltage 6 to 24 V | ||
Primary Voltage 117 to 230 V | ||
Number of Outputs 2 | ||
Length 32.6mm | ||
Width 27.6 mm | ||
Power 1.8VA | ||
Depth 27.3mm | ||
Weight 40g | ||
Mount Type PCB | ||
Isolation Voltage 4kV | ||
Maximum Operating Temperature 250°C | ||
Minimum Operating Frequency 50Hz | ||
Series 44000 | ||
Maximum Operating Frequency 60Hz | ||
Standards/Approvals EN 60950, EN 61558-2-6, UL 5085 | ||
RoHS Status: Exempt
- COO (Country of Origin):
- FR
Type EI 30 - 1 VA → 2.3 VA series 44000 transformers
From Myyra, the 44000 Series of type EI transformers are professional safety transformers featuring an insulation of above 4000V. Inherently short circuit proof and comprising of non-flammable and self-extinguishing materials, the 44000 series of transformers are extrememly reliable.
Features and Benefits:
• Professional safety transformers with insulation above 4000V.
• For installation on printed circuit boards (according to European grid).
• Coupling in series or parallel.
• Vacuum-filled with resin to ensure materials withstand aging.
• Unit and 100% control on automated line.
• Secondary voltages are nominal load voltages on resistive loads.
Encapsulated – Toroidal
Note
Fixing screws not provided
Approvals
UL, VDE
Standards
UL 94-V0; VDE 0551; IEC 742
Related links
- Myrra 9V ac 2 Output Through Hole PCB Transformer, 4VA
- Myrra 9V ac 2 Output Through Hole PCB Transformer, 2.3VA
- Myrra 9V ac 2 Output Through Hole PCB Transformer, 18VA
- Myrra 9V ac 2 Output Through Hole PCB Transformer, 3VA
- Myrra 9V ac 2 Output Through Hole PCB Transformer, 30VA
- Myrra 9V ac 2 Output Through Hole PCB Transformer, 1.5VA
- Myrra 9V ac 2 Output Through Hole PCB Transformer, 6VA
- Myrra 9V ac 2 Output Through Hole PCB Transformer, 14VA