Pico Technology TA Series TA041 Oscilloscope Probe, Differential Type, 25 MHz, BNC Connector

Subtotal (1 unit)*

PHP32,053.87

(exc. VAT)

PHP35,900.33

(inc. VAT)

Add to Basket
Select or type quantity
In Stock
  • 56 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per Unit
1 +PHP32,053.87

*price indicative

RS Stock No.:
898-6744
Distrelec Article No.:
300-15-496
Mfr. Part No.:
TA041
Manufacturer:
Pico Technology
Find similar products by selecting one or more attributes.
Select all

Brand

Pico Technology

Product Type

Oscilloscope Probe

Probe Type

Differential

Bandwidth

25MHz

Maximum Common Mode Input Voltage

700V

Connector Type

BNC

Model Number

TA041

Number of Probes

2

Safety Category Level

CAT III

Safety Category Voltage

1000V

Series

TA

Standards/Approvals

IEC 1010.1, IEC 1010.2 031, IEC 61010031

Rise Time

14ns

Pico Technology Oscilloscope Probe


The Pico Technology TA041 oscilloscope probe is an active differential probe, suitable for high common-mode voltage measurement applications up to ±700V. It can be used with a signal speed of up to 25Hz. This differential probe extends the functionality of standard single-ended input oscilloscopes to allow a safe and accurate method of making high voltage differential measurements.

By selecting attenuation ratio 1:10, this oscilloscope probe can measure signals below 70 V to get higher resolution and less noise. Or else, set the attenuation to 1:100.

Features and Benefits


Bandwidth is DC to 25MHz (–3dB)

Attenuation ratio is 10:1/100:1

Accuracy is ±2%

Input impedance is 4Mohm ll5.5pF each side to ground

Differential range is (10:1) ±70V (DC + peak AC) or 70VRMS

Maximum differential is (100:1) ±700V (DC + peak AC) or 700VRMS

Common mode range is ±700V (DC + peak AC) or 700VRMS (10:1 & 100:1)

Absolute maximum voltage is ±1400V (DC + peak AC) or 1000VRMS (10:1 & 100:1)

Swing is ±7V into 2kohm load

Offset (typical) is <±5mV

Noise (typical) is 0.7mVRMS

Source impedance is 1ohm at 1kHz and 8ohm at 20kHz

CMRR (typical) is 86dB at 50Hz and 66dB at 1MHz

Ambient operating temperature ranges between -10°C and 40°C

Power requirement 4xAA batteries or 6VDC/60mA mains adaptor or regulated 9VDC/40mA mains adaptor

Input lead length 450 mm

BNC lead length 950 mm

Dimensions (LxWxH): 170x63x21 mm

Applications


This probe is designed for carrying out differential measurements between two points on the circuit under test. It can be found in:

Safe measurement in power circuit

Acquisition of low speed balanced differential signals found in serial communications buses

Transients in switching power supplies, inverters and motor drives, electronic ballasts and CRT displays

Signals in the milliV range from sensors and other instrumentation

Certifications


IEC-1010.1

IEC-1010.2-031 CAT III

Pollution Degree 2.