Fluke 922 Differential Manometer, Max Pressure Measurement 6 psi
- RS Stock No.:
- 850-7672
- Mfr. Part No.:
- FLUKE 922
- Manufacturer:
- Fluke
Subtotal (1 unit)*
PHP71,372.00
(exc. VAT)
PHP79,936.64
(inc. VAT)
FREE delivery for orders over ₱3,000.00
Temporarily out of stock
- Shipping from July 13, 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per Unit |
|---|---|
| 1 + | PHP71,372.00 |
*price indicative
- RS Stock No.:
- 850-7672
- Mfr. Part No.:
- FLUKE 922
- Manufacturer:
- Fluke
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Accuracy | ±1 % | |
| Product Type | Manometer | |
| Maximum Pressure Measurement | 6psi | |
| Minimum Pressure Measurement | 6psi | |
| Pressure Port Type | Differential | |
| Minimum/Maximum Recordings | Yes | |
| Data Logging | Yes | |
| Model Number | 922 | |
| IP Rating | IP40 | |
| Minimum Operating Temperature | 0°C | |
| Battery Type | AA | |
| Maximum Operating Temperature | 50°C | |
| Display Type | LCD | |
| Battery Life | 375, 80h | |
| Height | 175mm | |
| Length | 41.9mm | |
| Standards/Approvals | CE | |
| Hazardous Area Certification | No | |
| Weight | 640g | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Accuracy ±1 % | ||
Product Type Manometer | ||
Maximum Pressure Measurement 6psi | ||
Minimum Pressure Measurement 6psi | ||
Pressure Port Type Differential | ||
Minimum/Maximum Recordings Yes | ||
Data Logging Yes | ||
Model Number 922 | ||
IP Rating IP40 | ||
Minimum Operating Temperature 0°C | ||
Battery Type AA | ||
Maximum Operating Temperature 50°C | ||
Display Type LCD | ||
Battery Life 375, 80h | ||
Height 175mm | ||
Length 41.9mm | ||
Standards/Approvals CE | ||
Hazardous Area Certification No | ||
Weight 640g | ||
RoHS Status: Exempt
- COO (Country of Origin):
- TW
Fluke Manometer, ±1% Accuracy, 10psi Maximum Pressure Measurement - FLUKE 922
This manometer is a handheld Airflow meter and micromanometer designed for HVAC and ventilation diagnostics, combining differential and static pressure, Air velocity and volume measurements in a single instrument for field use. It accepts pitot tube inputs and permits user entry of duct shape and size, enabling technicians to assess pressure relationships, balance ventilation and verify Airflow across filters and coils within normal site temperatures.
Features & Benefits
• Differential range up to 10psi with ±1% accuracy for precise readings
• Air velocity measurement to 16,000fpm allowing wide‑velocity coverage
• Airflow display to 99,999cfm for comprehensive volume reporting
• On‑board data logging storing 99 readings for later analysis
• Bright backlit LCD for visibility in poorly lit workspaces
• Four AA battery operation providing long run‑time under typical use
• Air velocity measurement to 16,000fpm allowing wide‑velocity coverage
• Airflow display to 99,999cfm for comprehensive volume reporting
• On‑board data logging storing 99 readings for later analysis
• Bright backlit LCD for visibility in poorly lit workspaces
• Four AA battery operation providing long run‑time under typical use
Applications
• Suitable for measuring pressure drops across filters and coils
• Ideal for performing duct traverses with pitot tube inputs
• Used for balancing ventilation to occupant loads
• Can be used to monitor indoor versus outdoor pressure relationships
• Suitable for verifying airflow and velocity in HVAC systems
• Ideal for performing duct traverses with pitot tube inputs
• Used for balancing ventilation to occupant loads
• Can be used to monitor indoor versus outdoor pressure relationships
• Suitable for verifying airflow and velocity in HVAC systems
What power options and battery endurance are available for extended jobs?
It runs from four AA batteries
typical operating life varies with backlight usage and can provide extended run‑times suitable for field surveys.
How does it handle measurement storage and later review?
The instrument stores up to 99 readings internally for download or manual transcription when completing site reports.
What environmental limits govern safe operation on site?
Operating temperatures span 0–50°C with non‑condensing humidity up to 90% and an IP40 ingress rating for routine indoor field conditions.
Which pressure ports and limits should users observe during measurement?
It uses differential pressure ports and each port accepts pressures up to 10psi maximum to protect sensors during testing.
Supplied with
2 x Rubber hoses, wrist strap, carrying case, operation manual, 4 x AA Alkaline batteries
Related links
- Fluke 922/KIT Differential Manometer Kit With 2 Pressure Port/s, Max Pressure Measurement 40 mbar
- Extech HD350 Differential Manometer, Max Pressure Measurement 10 psi
- RS PRO Differential Manometer With 2 Pressure Port/s, Max Pressure Measurement 150 hPa
- Kane KANE3200 Differential Manometer With 2 Pressure Port/s, Max Pressure Measurement 200 mbar
- Extech HD750 Differential Manometer With 2 Pressure Port/s, Max Pressure Measurement 5 psi
- Extech SDL710 Differential Manometer With 2 Pressure Port/s, Max Pressure Measurement 2.9 psi
- Extech 407910 Differential Manometer With 2 Pressure Port/s, Max Pressure Measurement 29 psi
- Extech SDL730 Differential Manometer With 2 Pressure Port/s, Max Pressure Measurement 101.5 psi

