Honeywell GLC Series Roller Plunger Limit Switch, 2 NC, IP66, Die Cast Zinc Housing, 600V ac, 10A
- RS Stock No.:
- 311-2257
- Mfr. Part No.:
- GLCC06C
- Manufacturer:
- Honeywell
Bulk discount available
Subtotal (1 unit)*
PHP7,135.97
(exc. VAT)
PHP7,992.29
(inc. VAT)
Stock information currently inaccessible - Please check back later
Units | Per Unit |
|---|---|
| 1 - 5 | PHP7,135.97 |
| 6 - 11 | PHP6,921.87 |
| 12 + | PHP6,714.23 |
*price indicative
- RS Stock No.:
- 311-2257
- Mfr. Part No.:
- GLCC06C
- Manufacturer:
- Honeywell
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Honeywell | |
| Actuator Type | Roller Plunger | |
| Product Type | Limit Switch | |
| IP Rating | IP66 | |
| Contact Configuration | 2 NC | |
| Housing Material | Die Cast Zinc | |
| Contact Type | Slow Action | |
| Terminal Type | M20 | |
| Switching Current | 10A | |
| Series | GLC | |
| Minimum Operating Temperature | -40°C | |
| Switching AC Voltage | 600V ac | |
| Switching DC Voltage | 250V dc | |
| Maximum Operating Temperature | 85°C | |
| Width | 30.5mm | |
| Length | 68.5mm | |
| Standards/Approvals | CCC, CE, CSA, UL | |
| Depth | 26.35mm | |
| Hazardous Area Certification | NO | |
| Conduit Entry | 20 mm | |
| Mechanical Life | 10000000Cycles | |
| Operating Force | 13N | |
| Select all | ||
|---|---|---|
Brand Honeywell | ||
Actuator Type Roller Plunger | ||
Product Type Limit Switch | ||
IP Rating IP66 | ||
Contact Configuration 2 NC | ||
Housing Material Die Cast Zinc | ||
Contact Type Slow Action | ||
Terminal Type M20 | ||
Switching Current 10A | ||
Series GLC | ||
Minimum Operating Temperature -40°C | ||
Switching AC Voltage 600V ac | ||
Switching DC Voltage 250V dc | ||
Maximum Operating Temperature 85°C | ||
Width 30.5mm | ||
Length 68.5mm | ||
Standards/Approvals CCC, CE, CSA, UL | ||
Depth 26.35mm | ||
Hazardous Area Certification NO | ||
Conduit Entry 20 mm | ||
Mechanical Life 10000000Cycles | ||
Operating Force 13N | ||

Honeywell GLC Series Limit Switch, Roller Plunger Actuator, 20mm Conduit Entry - GLCC06C
This limit switch provides mechanical position sensing for industrial and automation systems, using a roller plunger actuator to detect motion and trigger control circuits. Constructed with a robust die-cast zinc enclosure and sealed to IP66, it is suitable for demanding environments where ingress protection and repeatable switching are required. The device operates across a wide temperature range and employs slow-action contacts for reliable state changes in electrical control applications.
Features and Benefits:
• Two normally closed contacts for safe circuit interruption
• Slow-action switching for controlled contact transition
• Ten million-cycle mechanical life for prolonged service
• Operates between −40°C and 85°C for a wide temperature range
• 13 N actuation force for predictable trigger response
• M20 conduit entry for secure cable termination
• Slow-action switching for controlled contact transition
• Ten million-cycle mechanical life for prolonged service
• Operates between −40°C and 85°C for a wide temperature range
• 13 N actuation force for predictable trigger response
• M20 conduit entry for secure cable termination
Applications
• Suitable for conveyor end-of-travel detection in factories
• Ideal for door position monitoring on industrial enclosures
• Used for limit sensing on automated assembly machinery
• Can be used for safety interlocks in material handling systems
• Suitable for position feedback in electrical switchgear panels
• Ideal for door position monitoring on industrial enclosures
• Used for limit sensing on automated assembly machinery
• Can be used for safety interlocks in material handling systems
• Suitable for position feedback in electrical switchgear panels
What electrical ratings define the switchs load capability?
It can switch up to 10A and is rated for 600V AC and 250V DC, permitting use with common control and power circuits.
How does the enclosure material affect field use?
The die‑cast zinc housing offers mechanical resilience against impacts and supports long-term installation in industrial settings.
What termination provisions are provided for installation?
A 20mm conduit entry and M20 Terminal configuration allow standard conduit glands and secure cable routing.
Which approvals confirm suitability for regulated installations?
The unit carries CCC, CE, CSA and UL approvals, aligning it with multiple regional regulatory requirements.
How Compact is the device for panel or machine mounting?
The switch has a length of 68.5mm, a width of 30.5mm and a depth of 26.35mm to suit confined mounting spaces.
Approvals
UL/ UL listed for Canada
Warning
GLC and GLD limit switches are not safety devices. They should be not used as emergency stop or safety devices. They must not be used in applications where personal injury could occur as a result of product failure.
Standards
IEC/EN 60947-5-1
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.