Telemecanique Sensors XCKN Series Roller Lever Limit Switch, 1 NO/1 NC, IP65, Plastic Housing, 240V ac, 10A
- RS Stock No.:
- 125-8464
- Distrelec Article No.:
- 303-97-206
- Mfr. Part No.:
- XCKN2145G11
- Manufacturer:
- Telemecanique Sensors
Bulk discount available
View bulk pricing optionsSubtotal (1 unit)*
PHP2,902.01
(exc. VAT)
PHP3,250.25
(inc. VAT)
FREE delivery for orders over ₱3,000.00
Limited stock
- Plus 143 left, shipping from June 22, 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per Unit |
|---|---|
| 1 - 4 | PHP2,902.01 |
| 5 + | PHP2,388.35 |
*price indicative
- RS Stock No.:
- 125-8464
- Distrelec Article No.:
- 303-97-206
- Mfr. Part No.:
- XCKN2145G11
- Manufacturer:
- Telemecanique Sensors
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Telemecanique Sensors | |
| Actuator Type | Roller Lever | |
| Product Type | Limit Switch | |
| Contact Configuration | 1 NO/1 NC | |
| IP Rating | IP65 | |
| Housing Material | Plastic | |
| Contact Type | Snap Action | |
| Terminal Type | Screw Clamp | |
| Switching Current | 10A | |
| Series | XCKN | |
| Switching AC Voltage | 240V ac | |
| Switching DC Voltage | 250V dc | |
| Minimum Operating Temperature | -25°C | |
| Maximum Operating Temperature | 70°C | |
| Width | 30mm | |
| Length | 30mm | |
| Standards/Approvals | CSA Approved, UL Listed | |
| Depth | 42mm | |
| Hazardous Area Certification | No | |
| Operating Force | 0.1Nm | |
| Conduit Entry | 1 Cable Gland x PG 11 | |
| Mechanical Life | 10000000Cycles | |
| Select all | ||
|---|---|---|
Brand Telemecanique Sensors | ||
Actuator Type Roller Lever | ||
Product Type Limit Switch | ||
Contact Configuration 1 NO/1 NC | ||
IP Rating IP65 | ||
Housing Material Plastic | ||
Contact Type Snap Action | ||
Terminal Type Screw Clamp | ||
Switching Current 10A | ||
Series XCKN | ||
Switching AC Voltage 240V ac | ||
Switching DC Voltage 250V dc | ||
Minimum Operating Temperature -25°C | ||
Maximum Operating Temperature 70°C | ||
Width 30mm | ||
Length 30mm | ||
Standards/Approvals CSA Approved, UL Listed | ||
Depth 42mm | ||
Hazardous Area Certification No | ||
Operating Force 0.1Nm | ||
Conduit Entry 1 Cable Gland x PG 11 | ||
Mechanical Life 10000000Cycles | ||
Telemecanique Sensors XCKN Series Limit Switch, 1NO/1NC Contact Configuration, IP65 - XCKN2145G11
This limit switch provides a Compact mechanical sensing solution for control and safety circuits in industrial installations. It employs a roller lever actuator to detect linear or rotary motion and transmit a snap-action electrical signal. The device is housed in a protective plastic enclosure rated for use where ingress protection is required, and it connects via a single cable gland.
Features and Benefits:
• Snap-action contacts deliver quick definitive switching performance
• Dual contact arrangement offers both make and break outputs
• Rated for 10A switching at mains-level AC voltages
• Operates reliably across -25°C to 70°C ambient temperatures
• Sealed enclosure achieves IP65 protection against dust and jets
• Screw-clamp terminals simplify secure field wiring connections
• Dual contact arrangement offers both make and break outputs
• Rated for 10A switching at mains-level AC voltages
• Operates reliably across -25°C to 70°C ambient temperatures
• Sealed enclosure achieves IP65 protection against dust and jets
• Screw-clamp terminals simplify secure field wiring connections
Applications
• Suitable for end-of-travel detection on conveyor systems
• Ideal for position sensing in automated assembly stations
• Used with safety interlocks on access panels and guards
• Can be used for actuation monitoring of pneumatic cylinders
• Suitable for machine tool limit detection and control loops
• Ideal for position sensing in automated assembly stations
• Used with safety interlocks on access panels and guards
• Can be used for actuation monitoring of pneumatic cylinders
• Suitable for machine tool limit detection and control loops
How is the electrical connection MADE for field wiring?
Wiring is terminated to screw-clamp terminals and routed through a single PG11 cable gland for strain relief and sealing.
What contact types are available within the device and how do they behave?
The internal mechanism provides one normally open and one normally closed contact with snap-action operation for Rapid contact transfer.
How many mechanical cycles can the switch endure before replacement?
The mechanism is rated for ten million mechanical operations under specified conditions.
What are the ambient temperature limits for reliable operation?
The device is specified to function over a temperature range from -25°C up to 70°C.
Is the enclosure suitable for environments where dust or water jets are present?
The housing meets IP65 criteria, providing protection against ingress of dust and low-pressure water jets.
Related links
- Telemecanique Sensors OsiSense XC Series Roller Lever Limit Switch IP65 240V ac, 10A
- Telemecanique Sensors OsiSense XC Series Plunger Roller Lever Limit Switch IP65 240V ac, 10A
- Telemecanique Sensors OsiSense XC Series Roller Plunger Limit Switch IP65 240V ac, 10A
- Telemecanique Sensors OsiSense XC Series Rod Limit Switch IP65 240V ac, 10A
- Telemecanique Sensors OsiSense XC Series Spring Plunger Limit Switch IP65 240V ac, 10A
- Telemecanique Sensors OsiSense XC Series Roller Plunger Limit Switch IP65 240V ac, 6A
- Telemecanique Sensors OsiSense XC Series Rod Limit Switch IP65 240V ac, 6A