SICK FTS Series Fluid Sensor Flow Sensor for Liquid, 3cm/s Min, 600cm/s Max

Subtotal (1 unit)*

PHP35,827.95

(exc. VAT)

PHP40,127.30

(inc. VAT)

Add to Basket
Select or type quantity
Limited stock
  • 1 left, ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per Unit
1 +PHP35,827.95

*price indicative

RS Stock No.:
285-9500
Mfr. Part No.:
FTS-I200F14B
Manufacturer:
SICK
Find similar products by selecting one or more attributes.
Select all

Brand

SICK

Product Type

Flow Sensor

Media Monitored

Liquid

Device Type

Fluid Sensor

Minimum Flow Rate

3cm/s

Housing Material

Vistal

Maximum Flow Rate

600cm/s

Connection Type

M12

Maximum Pressure

100bar

Maximum Supply Voltage

30V dc

IP Rating

IP67

Minimum Media Temperature

-40°C

Minimum Operating Temperature

-40°C

Maximum Media Temperature

150°C

Maximum Operating Temperature

70°C

Series

FTS

Standards/Approvals

EN 61326-1, EN 61326-2-3, UL61010-1:2012-05

Current Rating

100mA

COO (Country of Origin):
DE

Overview


The T-Easic FTS thermal flow sensor measures flow and temperature of liquids in accordance with the calorimetric principle. Available as an industrial variant with VISTAL® housing and display or as a hygienic stainless-steel variant, the T-Easic® FTS is s

A special feature is integrated empty pipe detection for optimal dry-run protection in pumps. Parameterization can be done via IO-Link or the display. Media taught-in at the factory such as oil and water accelerate commissioning; other liquids can be cali

At a glance


Flow monitoring and temperature measurement in one sensor

Optimized for water and oil; teach-in option of other liquids

IP 67/IP 69 enclosure rating and IO-Link 1.1

Industrial design in VISTAL® housing with 180°-rotatable OLED display

Stainless steel hygi

Your Benefit


One sensor, two measurements – reduces costs and hygiene risk thanks to a unique installation point

Optimal pump protection thanks integrated empty pipe detection

Automated measurement data acquisition via analogue output or IO-Link

Volume recording thank

Applications


Related links