Endress+Hauser DMA25 Series Electromagnetic Flowmeter Flow Meter for Liquid, 0.2L/min Min, 150L/min Max
- RS Stock No.:
- 256-6154
- Distrelec Article No.:
- 303-51-193
- Mfr. Part No.:
- DMA25-AAAAA1
- Manufacturer:
- Endress+Hauser
This image is representative of the product range
Subtotal (1 unit)*
PHP50,602.55
(exc. VAT)
PHP56,674.86
(inc. VAT)
FREE delivery for orders over ₱3,000.00
In Stock
- 48 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per Unit |
|---|---|
| 1 + | PHP50,602.55 |
*price indicative
- RS Stock No.:
- 256-6154
- Distrelec Article No.:
- 303-51-193
- Mfr. Part No.:
- DMA25-AAAAA1
- Manufacturer:
- Endress+Hauser
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Endress+Hauser | |
| Media Monitored | Liquid | |
| Product Type | Flow Meter | |
| Device Type | Electromagnetic Flowmeter | |
| Minimum Flow Rate | 0.2L/min | |
| Housing Material | 316L Stainless Steel | |
| Maximum Flow Rate | 150L/min | |
| Connection Type | Thread | |
| Maximum Pressure | 16bar | |
| Maximum Supply Voltage | 30V dc | |
| Minimum Media Temperature | -10°C | |
| IP Rating | IP65, IP67 | |
| Maximum Media Temperature | 70°C | |
| Minimum Operating Temperature | -10°C | |
| Maximum Operating Temperature | 60°C | |
| Series | DMA25 | |
| Standards/Approvals | CE mark | |
| Select all | ||
|---|---|---|
Brand Endress+Hauser | ||
Media Monitored Liquid | ||
Product Type Flow Meter | ||
Device Type Electromagnetic Flowmeter | ||
Minimum Flow Rate 0.2L/min | ||
Housing Material 316L Stainless Steel | ||
Maximum Flow Rate 150L/min | ||
Connection Type Thread | ||
Maximum Pressure 16bar | ||
Maximum Supply Voltage 30V dc | ||
Minimum Media Temperature -10°C | ||
IP Rating IP65, IP67 | ||
Maximum Media Temperature 70°C | ||
Minimum Operating Temperature -10°C | ||
Maximum Operating Temperature 60°C | ||
Series DMA25 | ||
Standards/Approvals CE mark | ||
- COO (Country of Origin):
- FR
Endress+Hauser DMA25 Series Flow Meter, 150 L/min Maximum Flow Rate, 16 Bar Maximum Pressure - DMA25-AAAAA1
This flow metre is an inline electromagnetic device designed to measure liquid flow in industrial settings. It operates across a broad flow range and is intended for use where robust construction and protection against ingress are required. The unit connects via threaded fittings and is suitable for environments that demand stainless-steel wetted parts and regulated electrical supply.
Features and Benefits:
• Electromagnetic measurement delivers high accuracy across range 0.2-150 L/min
• 316L stainless steel housing resists corrosion in process lines
• IP65 and IP67 protection enables washdown and temporary immersion
• Rated for media temperatures up to 70°C for warm-fluid handling
• 16 bar maximum pressure supports pressurised pipeline systems
• Accepts up to 30V DC supply for low-voltage industrial control
• 316L stainless steel housing resists corrosion in process lines
• IP65 and IP67 protection enables washdown and temporary immersion
• Rated for media temperatures up to 70°C for warm-fluid handling
• 16 bar maximum pressure supports pressurised pipeline systems
• Accepts up to 30V DC supply for low-voltage industrial control
Applications
• Suitable for water treatment dosing and monitoring loops
• Ideal for chemical feed control with corrosive liquids
• Used for flow verification in food and beverage processing lines
• Can be used for plant utilities metering in production facilities
• Used with control systems requiring threaded inline sensors
• Ideal for chemical feed control with corrosive liquids
• Used for flow verification in food and beverage processing lines
• Can be used for plant utilities metering in production facilities
• Used with control systems requiring threaded inline sensors
What connection type is used for installation in a pipework system?
Threaded connections allow direct inline mounting into existing threaded pipe fittings and adaptors.
How does the device perform in washdown or rainy conditions?
The enclosure meets IP65 and IP67 levels, protecting electronics during routine washdowns and brief submersion events.
What temperature range can the transmitter and measured media tolerate?
The instrument operates in ambient conditions down to -10°C while handling media temperatures as high as 70°C.
What maximum supply and pressure constraints must be observed?
The unit must not exceed a 30V DC supply and is qualified for process pressures up to 16 bar.
Which media is suitable for measurement with this technology?
The sensor is designed for conductive liquids, using electromagnetic principles to determine volumetric flow.
Related links
- Endress+Hauser DMA2 Series Conductive Liquids Flow Meter for Liquid 150L/min Max
- Endress+Hauser DMA2 Series Conductive Liquids Flow Meter for Liquid 75L/min Max
- Endress+Hauser DMA5 Series Conductive Liquids Flow Meter for Liquid 750L/min Max
- ifm electronic SV8051 Series Vortex Flow Meter Flow Meter for Water 150L/min Max
- ifm electronic SV8151 Series Vortex Flow Meter Flow Meter for Water 150L/min Max
- Sensirion SFM3003 Series Digital Flow Sensor for Gas 300L/min Max
- Endress+Hauser Picomag Series Flow Meter to 35L/min
- Festo SFAM Series Flow Sensor Flow Sensor for Air 15000L/min Max