Recom RKZ DC/DC Converter, 15V dc/ 67 mA, 26.4V dc Input, 21.6V Input 2 W, Through Hole, 85 °C Max Temp -40 °C Min Temp,

This image is representative of the product range

Bulk discount available

Subtotal (1 tube of 25 units)*

PHP20,911.29

(exc. VAT)

PHP23,420.64

(inc. VAT)

Add to Basket
Select or type quantity
Temporarily out of stock
  • Shipping from August 24, 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.

Tube(s)
Per Tube
Per Unit*
1 - 1PHP20,911.29PHP836.452
2 - 3PHP20,451.24PHP818.05
4 +PHP20,012.13PHP800.485

*price indicative

RS Stock No.:
166-6570
Mfr. Part No.:
RKZ-241509D
Manufacturer:
Recom
Find similar products by selecting one or more attributes.
Select all

Brand

Recom

Output Voltage 1

15V dc

Product Type

DC/DC Converter

Minimum Input Voltage

21.6V

Maximum Input Voltage

26.4V dc

Output Current 1

67mA

Output Current 2

111mA

Mount Type

Through Hole

Output Voltage 2

-9V dc

MTBF

1830000h

Number of Outputs

2

Isolation Voltage

3kV dc

Number of Pins

7

Package Type

SIP

Maximum Output Power

2W

Standards/Approvals

No

Series

RKZ

Length

19.5mm

Depth

10.2mm

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

85°C

Efficiency

81%

COO (Country of Origin):
TW

Recom 2W SIP Single/Dual Output Medical Approved Unregulated Isolated DC-DC Converter - RKZ Series


The Recom RKZ Series of 2W DC/DC Converters are certified to EN 60950-1 and to the medical standard EN-60601-1. This makes these DC/DC converters suitable for high end industrial applications such as IGBT driver circuitry as well as standard medical applications. The RKZ isolated converters are pin-compatible with the RK and RH DC/DC converter series, offering a simple way to upgrade a 1W high isolation supply to 2W.

High isolation 2W converter

Approved for medical applications

3k Vdc and 4k Vdc isolation options

UL94V-0 Package Material

Efficiency 84%

Suitable for IGBT Applications

SIP7 package

3 year warranty

Note

MTBF to MIL-HDBK 217F.
Operating temperature is without derating.

Standards

EN-60950-1, EN-60601-1