TRACOPOWER THM 6WI DC/DC Converter, 5V dc/ 600 mA, 9V dc Input, 4.5V Input 6 W, PCB, 95 °C Max Temp -40 °C Min Temp,

Bulk discount available
View bulk pricing option

Subtotal (1 tube of 10 units)*

PHP31,018.28

(exc. VAT)

PHP34,740.47

(inc. VAT)

Add to Basket
Select or type quantity
Temporarily out of stock
  • Shipping from November 04, 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.

Tube(s)
Per Tube
Per Unit*
1 - 1PHP31,018.28PHP3,101.828
2 - 3PHP30,335.87PHP3,033.587
4 +PHP29,684.48PHP2,968.448

*price indicative

RS Stock No.:
166-6244
Mfr. Part No.:
THM 6-0521WI
Manufacturer:
TRACOPOWER
Find similar products by selecting one or more attributes.
Select all

Brand

TRACOPOWER

Product Type

DC/DC Converter

Output Voltage 1

5V dc

Maximum Input Voltage

9V dc

Minimum Input Voltage

4.5V

Output Current 1

600mA

Output Current 2

600mA

Mount Type

PCB

Output Voltage 2

-5V dc

Number of Outputs

2

MTBF

4700000h

Output Voltage Adjustment Range

-10 to 20 %

Number of Pins

24

Isolation Voltage

5kV ac

Maximum Output Power

6W

Package Type

DIP-24

Length

31.8mm

Depth

10.2mm

Series

THM 6WI

Standards/Approvals

No

Minimum Operating Temperature

-40°C

Efficiency

84%

Maximum Operating Temperature

95°C

COO (Country of Origin):
TW

Traco 6W DIP Single/Dual Output Regulated Isolated DC-DC Converter - THM 6WI Serie


The Tracopower THM-6WI comes in a DIP-24 plastic package, with high efficiency of up to 88% and highest grade components the DC/DC converters can operate at a temperature range of -40 up to +88°C. The reinforced I/O-isolation of this high performance regulated DC/DC converter complies with medical safety requirements for MOPP (Means Of Patient Protection). This range of DC/DC converters feature a wide 4:1 input voltage range and an internal EMI filter meeting EN55022 class A, which makes the THM-6WI a reliable solution for demanding applications, such as transportation systems, industrial control equipments, measurement equipments and some IGBT drivers applications.

Ultra wide 4:1 input voltage

I/O isolation 5000 VACrms rated for 250 working voltage

2 x MOPP Medical safety

Low leakage current ˂2 μA

Very high efficiency up to 88%

Extended operating temperature range –40°C to 88°C at full load

Input filter to meet EN55022 class A

3-year product warranty

Approvals

UL online certification UL 60601-1

Standards

ANSI/AAMI ES 60601-1
2005/(R) 2012
IEC/EN 60601-1 3rd edition

Related links