Alpha Wire Xtra-Guard 2 Performance Cable Control Cable, 8 Cores, 0.56 mm² 20 AWG, Screened, 30 m, Black Polyvinyl
- RS Stock No.:
- 873-1291
- Mfr. Part No.:
- 25468 BK005
- Manufacturer:
- Alpha Wire
Subtotal (1 reel of 30 metres)*
PHP39,517.02
(exc. VAT)
PHP44,259.06
(inc. VAT)
FREE delivery for orders over ₱3,000.00
Temporarily out of stock
- 3 unit(s) shipping from April 21, 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Reel(s) | Per Reel | Per Metre* |
|---|---|---|
| 1 + | PHP39,517.02 | PHP1,317.234 |
*price indicative
- RS Stock No.:
- 873-1291
- Mfr. Part No.:
- 25468 BK005
- Manufacturer:
- Alpha Wire
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Alpha Wire | |
| Series | Xtra-Guard 2 Performance Cable | |
| Product Type | Control Cable | |
| Number of Cores | 8 | |
| Conductor Material | Tin Copper Wire | |
| Jacket Material | Polyvinyl Chloride | |
| Jacket Colour | Black | |
| Armoured | Yes | |
| Screened/Unscreened | Screened | |
| Cable Length | 30m | |
| Outside Diameter | 7.77 mm | |
| Voltage | 300 V | |
| Minimum Operating Temperature | -30°C | |
| Standards/Approvals | CSA, UL, CE | |
| Maximum Operating Temperature | 90°C | |
| Cable CSA | 0.56 mm² | |
| Hazardous Area Certification | No | |
| Fire Behaviour | IEC 60332-1, Flame resistance according to UL, Flame Retardant, IEC 60332-1-2, Low Flammability | |
| American Wire Gauge | 20AWG | |
| Core Strands | 7 | |
| Select all | ||
|---|---|---|
Brand Alpha Wire | ||
Series Xtra-Guard 2 Performance Cable | ||
Product Type Control Cable | ||
Number of Cores 8 | ||
Conductor Material Tin Copper Wire | ||
Jacket Material Polyvinyl Chloride | ||
Jacket Colour Black | ||
Armoured Yes | ||
Screened/Unscreened Screened | ||
Cable Length 30m | ||
Outside Diameter 7.77 mm | ||
Voltage 300 V | ||
Minimum Operating Temperature -30°C | ||
Standards/Approvals CSA, UL, CE | ||
Maximum Operating Temperature 90°C | ||
Cable CSA 0.56 mm² | ||
Hazardous Area Certification No | ||
Fire Behaviour IEC 60332-1, Flame resistance according to UL, Flame Retardant, IEC 60332-1-2, Low Flammability | ||
American Wire Gauge 20AWG | ||
Core Strands 7 | ||
Belden Xtra-Guard 2 Performance Cable Series Control Cable, 8 Cores, 0.56mm² Cross Sectional Area - 25468 BK005
This control cable is an 8-core solution designed for a range of industrial applications. Engineered for durability and performance, it features a length of 30m and is crafted from tinned copper conductors, with a PVC insulation layer to ensure reliable operation in challenging environments. With a maximum operating temperature of +90°C and a voltage rating of 300V, this screened control cable meets CE, CSA, and UL standards, providing peace of mind in any installation.
Features & Benefits
• Screened design reduces electromagnetic interference for improved signal integrity
• Tinned copper construction enhances corrosion resistance and durability
• 20 AWG size ensures compatibility with various electronic devices
• PVC insulation provides excellent protection against external elements
• Maximum temperature rating of +90°C allows for high-performance applications
• Compliant with international standards for broader usability in global markets
Applications
• Used for wiring in automation systems and machinery
• Suitable for requiring high voltage ratings
• Ideal for connections in control panels and industrial equipment
• Utilised in electronic devices where reliable performance is critical
• Effective for installations in harsh environments requiring robust cabling
What is the significance of the screened design in this cable?
The screened design plays a crucial role in minimising electromagnetic interference, allowing for clear and stable signal transmission. This is particularly important in automated and electronic systems where interruptions can lead to performance issues.
What is the importance of tinned copper in the construction?
Tinned copper enhances resistance to corrosion and oxidation, making the cable suitable for applications in various environments, including those exposed to moisture or chemicals.
How does the PVC insulation contribute to the cable's performance?
PVC insulation provides effective protection against mechanical damage, abrasion, and environmental factors, ensuring the cable maintains functionality in demanding conditions and extending its lifespan.
What is the minimum bend radius for effective installation?
The minimum bend radius is 10 times the diameter of the cable, ensuring that the cable does not suffer damage during installation or operation, which is critical for maintaining performance standards and longevity.
Related links
- Alpha Wire Xtra-Guard 2 Performance Cable Control Cable 0.56 mm² 20 AWG 30 m, Black Polyvinyl
- Alpha Wire Xtra-Guard 2 Performance Cable Control Cable 0.56 mm² 20 AWG 30 m, Black Polyvinyl
- Alpha Wire Xtra-Guard 2 Performance Cable Control Cable 0.56 mm² 20 AWG 30 m, Black Polyvinyl
- Alpha Wire Xtra-Guard 2 Performance Cable Control Cable 0.56 mm² 20 AWG 30 m, Black Polyvinyl
- Alpha Wire Xtra-Guard 2 Performance Cable Control Cable 0.56 mm² 20 AWG 30 m, Black Polyvinyl
- Alpha Wire Xtra-Guard 2 Performance Cable Control Cable 0.56 mm² 20 AWG 30 m, Black Polyvinyl
- Alpha Wire Xtra-Guard 2 Performance Cable Control Cable 0.35 mm² 22 AWG 30 m, Black Polyvinyl
- Alpha Wire XTRA-GUARD 2 Control Cable 0.56 mm² 20 AWG 30 m, Black Polyvinyl Chloride Sheath