Lapp OLFLEX CLASSIC 115 CY Control Cable, 7 Cores, 0.5 mm² CSA 20 AWG, Screened, 50 m, Silver Grey Polyvinyl Chloride
- RS Stock No.:
- 280-5099
- Distrelec Article No.:
- 300-49-534
- Mfr. Part No.:
- 1136007
- Manufacturer:
- Lapp
Subtotal (1 reel of 50 metres)*
PHP10,656.33
(exc. VAT)
PHP11,935.09
(inc. VAT)
FREE delivery for orders over ₱3,000.00
In Stock
- 3 unit(s) ready to ship from another location
- Plus 3 unit(s) shipping from January 09, 2026
- Plus 11 unit(s) shipping from February 13, 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Reel(s) | Per Reel | Per Metre* |
|---|---|---|
| 1 + | PHP10,656.33 | PHP213.127 |
*price indicative
- RS Stock No.:
- 280-5099
- Distrelec Article No.:
- 300-49-534
- Mfr. Part No.:
- 1136007
- Manufacturer:
- Lapp
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Lapp | |
| Series | OLFLEX CLASSIC 115 CY | |
| Product Type | Control Cable | |
| Number of Cores | 7 | |
| Cross Sectional Area | 0.5 mm² | |
| Conductor Material | Copper | |
| Jacket Material | Polyvinyl Chloride | |
| Jacket Colour | Silver Grey | |
| Screened/Unscreened | Screened | |
| Outside Diameter | 7.5 mm | |
| Cable Length | 50m | |
| Voltage | 4000 V | |
| Conductor Type | Stranded | |
| Minimum Operating Temperature | -40°C | |
| Maximum Operating Temperature | 80°C | |
| Standards/Approvals | EN 50525-2-51 resp. VDE 0285-525-2-51, EU-Directives 2014/35/EU (Low Voltage Directive) | |
| American Wire Gauge | 20AWG | |
| Fire Behaviour | Flammability acc. to IEC 60332-1-2 resp. VDE 0482-332-1-2 | |
| Core Strands | 7 | |
| Distrelec Product Id | 300-49-534 | |
| Select all | ||
|---|---|---|
Brand Lapp | ||
Series OLFLEX CLASSIC 115 CY | ||
Product Type Control Cable | ||
Number of Cores 7 | ||
Cross Sectional Area 0.5 mm² | ||
Conductor Material Copper | ||
Jacket Material Polyvinyl Chloride | ||
Jacket Colour Silver Grey | ||
Screened/Unscreened Screened | ||
Outside Diameter 7.5 mm | ||
Cable Length 50m | ||
Voltage 4000 V | ||
Conductor Type Stranded | ||
Minimum Operating Temperature -40°C | ||
Maximum Operating Temperature 80°C | ||
Standards/Approvals EN 50525-2-51 resp. VDE 0285-525-2-51, EU-Directives 2014/35/EU (Low Voltage Directive) | ||
American Wire Gauge 20AWG | ||
Fire Behaviour Flammability acc. to IEC 60332-1-2 resp. VDE 0482-332-1-2 | ||
Core Strands 7 | ||
Distrelec Product Id 300-49-534 | ||
RoHS Status: Exempt
- COO (Country of Origin):
- DE
LAPP OLFLEX CLASSIC 115 CY Series Control Cable, 50m Length, 0.5 mm² Cross Sectional Area - 1136007
This control cable is designed for flexible and fixed installations under medium mechanical strain. With a length of 50m and a round shape, this 0.5 mm² control cable features a durable PVC sheath in silver grey. Ideal for use in various environments, it boasts a voltage rating of 300/500 V, making it suitable for demanding tasks in automation and electrical applications.
Features & Benefits
• Utilises a screened design to minimise electrical interference
• Flame retardant properties ensure safety in critical usage
• Capable of withstanding temperatures from -40°C to +80°C
• Composed of bare copper for excellent conductivity
• Rated for occasional flexible use in diverse settings
• PVC sheath offers resistance to acids and alkalis
Applications
• Utilised in control units for machine tools
• Implemented in conveyor systems for efficient operations
• Suitable for measurement and control technology
• Used in data processing systems for reliable connections
• Recommended for occasional movement, such as in wind turbines
What is the maximum load capacity during installation?
The maximum tensile load is 15 N/mm² of the conductor cross-section, ensuring it can handle significant stress during both installation and operation.
Can this cable be used outdoors?
Yes, it can be used outdoors, provided UV protection is applied, and it operates within the specified temperature range.
How does the screening impact performance?
The screening braid significantly reduces the effects of external electrical fields, allowing for consistent signal integrity in sensitive applications.
What are the bending radius specifications?
For occasional flexing, the minimum bending radius is 20 times the cable diameter, while fixed installations require a 6 times diameter bending radius.
Related links
- Lapp OLFLEX CLASSIC 115 CY Control Cable 0.5 mm² CSA 20 AWG 50 m, Silver Grey Polyvinyl Chloride
- Lapp OLFLEX CLASSIC 115 CY Control Cable 0.75 mm² CSA 18 AWG 50 m, Silver Grey Polyvinyl Chloride
- Lapp OLFLEX CLASSIC 115 CY Control Cable 0.75 mm² CSA 18 AWG 50 m, Silver Grey Polyvinyl Chloride
- Lapp OLFLEX CLASSIC 115 CY Control Cable 1 mm² CSA 17 AWG 50 m, Silver Grey Polyvinyl Chloride
- Lapp OLFLEX CLASSIC 115 Control Cable 0.75 mm² CSA 19 50 m, Silver Grey Polyvinyl Chloride Sheath
- Lapp OLFLEX CLASSIC FD 810 Control Cable 1.5 mm² CSA 16 AWG 50 m, Silver Grey Polyvinyl Chloride
- Lapp OLFLEX CLASSIC FD 810 Control Cable 1.5 mm² CSA 16 AWG 50 m, Silver Grey Polyvinyl Chloride
- Lapp OLFLEX CLASSIC FD 810 Control Cable 1.5 mm² CSA 16 AWG 50 m, Silver Grey Polyvinyl Chloride