Alpha Wire XTRA-GUARD 2 Control Cable, 3 Cores, 0.56mm² 20 AWG, Screened, 30 m, Black Polyvinyl Chloride Sheath
- RS Stock No.:
- 409-242
- Mfr. Part No.:
- 25463 BK005
- Manufacturer:
- Alpha Wire
Subtotal (1 reel of 30 metres)*
PHP13,886.92
(exc. VAT)
PHP15,553.35
(inc. VAT)
FREE delivery for orders over ₱3,000.00
In Stock
- 1 unit(s) ready to ship from another location
- Plus 74 unit(s) shipping from April 14, 2026
- Plus 23 unit(s) shipping from April 21, 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Reel(s) | Per Reel | Per Metre* |
|---|---|---|
| 1 + | PHP13,886.92 | PHP462.897 |
*price indicative
- RS Stock No.:
- 409-242
- Mfr. Part No.:
- 25463 BK005
- Manufacturer:
- Alpha Wire
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Alpha Wire | |
| Series | XTRA-GUARD 2 | |
| Product Type | Control Cable | |
| Number of Cores | 3 | |
| Conductor Material | Tin Copper Wire | |
| Jacket Material | Polyvinyl Chloride | |
| Jacket Colour | Black | |
| Armoured | Yes | |
| Screened/Unscreened | Screened | |
| Cable Length | 30m | |
| Outside Diameter | 5.66mm | |
| Voltage | 300V | |
| Minimum Operating Temperature | -30°C | |
| Standards/Approvals | CSA, UL, CE | |
| Maximum Operating Temperature | 90°C | |
| Cable CSA | 0.56mm² | |
| Hazardous Area Certification | No | |
| American Wire Gauge | 20AWG | |
| Fire Behaviour | Flame Retardant to IEC 60332-1-2, Low Smoke Zero Halogen (LSZH), CPR, Flame resistance to UL1581 VW-1 and IEC60332-1 | |
| Core Strands | 7 | |
| Select all | ||
|---|---|---|
Brand Alpha Wire | ||
Series XTRA-GUARD 2 | ||
Product Type Control Cable | ||
Number of Cores 3 | ||
Conductor Material Tin Copper Wire | ||
Jacket Material Polyvinyl Chloride | ||
Jacket Colour Black | ||
Armoured Yes | ||
Screened/Unscreened Screened | ||
Cable Length 30m | ||
Outside Diameter 5.66mm | ||
Voltage 300V | ||
Minimum Operating Temperature -30°C | ||
Standards/Approvals CSA, UL, CE | ||
Maximum Operating Temperature 90°C | ||
Cable CSA 0.56mm² | ||
Hazardous Area Certification No | ||
American Wire Gauge 20AWG | ||
Fire Behaviour Flame Retardant to IEC 60332-1-2, Low Smoke Zero Halogen (LSZH), CPR, Flame resistance to UL1581 VW-1 and IEC60332-1 | ||
Core Strands 7 | ||
Belden XTRA-GUARD 2 Series Control Cable, 30m Cable Length, 3 Cores - 25463 BK005
This control cable is a screened, three-core product designed for industrial signalling and control in automation and electrical systems. It is intended for installations requiring a robust, flame-retardant conductor assembly with reduced halogen emissions and a Durable outer sheath suitable for varied ambient conditions.
Features & Benefits
• Tin-plated copper conductors reduce corrosion and improve conductivity
• Screened construction limits electromagnetic interference for accurate signals
• Rated 300V to support common low-voltage control circuits
• Operating temperature range -30°C to 90°C for broad environmental use
• Low smoke zero halogen jacket limits toxic emissions in confined spaces
• VW-1/IEC flame resistance improves safety during fire exposure
• Screened construction limits electromagnetic interference for accurate signals
• Rated 300V to support common low-voltage control circuits
• Operating temperature range -30°C to 90°C for broad environmental use
• Low smoke zero halogen jacket limits toxic emissions in confined spaces
• VW-1/IEC flame resistance improves safety during fire exposure
Applications
• Suitable for factory automation control panels and motor controllers
• Ideal for wiring machine tools and conveyor control systems
• Used with distributed I/O and PLC field connections
• Can be used for robotics signal and sensor cabling in plants
• Suitable for indoor cable runs where reduced smoke is required
• Ideal for wiring machine tools and conveyor control systems
• Used with distributed I/O and PLC field connections
• Can be used for robotics signal and sensor cabling in plants
• Suitable for indoor cable runs where reduced smoke is required
What conductor construction is used to meet flexibility needs?
Each core comprises multiple fine strands of tin-plated copper configured as 20 AWG (7/28) to balance flexibility with electrical performance.
How is the screening implemented and what benefit does it give?
An aluminium/Mylar foil with a tinned-copper drain wire provides overall screening to reduce external electromagnetic disturbance and simplify termination to earth.
What materials form the insulation and outer sheath?
Individual cores are insulated with nominal PVC and the outer jacket is a polyurethane-specified construction that provides mechanical protection and sunlight resistance.
How does the cable behave electrically for system design?
Nominal capacitance and inductance values are provided for engineering calculations, and conductor DCR and overall shield DCR allow accurate resistance estimates for lengths.
What handling limits should be observed during installation?
Follow a minimum bend radius of 10x cable diameter and keep pull tension below the specified maximum to avoid mechanical damage.
Related links
- Alpha Wire XTRA-GUARD 2 Control Cable 0.56 mm² 20 AWG 30 m, Black Polyvinyl Chloride Sheath
- Alpha Wire XTRA-GUARD 2 Control Cable 0.56 mm² 20 AWG 30 m, Black Polyvinyl Chloride Sheath
- Alpha Wire XTRA-GUARD 2 Control Cable 0.35 mm² 22 AWG 30 m, Black Polyvinyl Chloride Sheath
- Alpha Wire Xtra-Guard 2 Performance Cable Control Cable 0.56 mm² 20 AWG 30 m, Black Polyvinyl
- Alpha Wire Xtra-Guard 2 Performance Cable Control Cable 0.56 mm² 20 AWG 30 m, Black Polyvinyl
- Alpha Wire XTRA-GUARD 2 Control Cable 0.23 mm² 24 AWG 30 m, Black Polyvinyl Chloride Sheath
- Alpha Wire XTRA-GUARD 2 Control Cable 0.35 mm² 22 AWG 30 m, Black Polyvinyl Chloride Sheath
- Alpha Wire XTRA-GUARD 2 Control Cable 0.81 mm² 18 AWG 30 m, Black Polyvinyl Chloride Sheath