Eaton DILM Contactor, 24 V dc Coil, 3-Pole, 7 A, 3 kW 24 V dc, 3 NO, 400V ac

Subtotal (1 unit)*

PHP3,409.51

(exc. VAT)

PHP3,818.65

(inc. VAT)

Add to Basket
Select or type quantity
In Stock
  • 35 unit(s) ready to ship from another location
  • Plus 21 unit(s) shipping from March 17, 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per Unit
1 +PHP3,409.51

*price indicative

RS Stock No.:
743-4908
Distrelec Article No.:
136-22-402
Mfr. Part No.:
276565 DILM7-10(24VDC)
Manufacturer:
Eaton
Find similar products by selecting one or more attributes.
Select all

Brand

Eaton

Product Type

Contactor

Coil Voltage

24 V dc

Number of Poles

3

Contact Voltage

400V ac

Contact Current

7A

Power Rating

3kW

Series

DILM

Mount Type

DIN Rail

Function

Motor Control, Resistive Load

Normal State Configuration

3 NO

Number of Auxiliary Contacts

1

Auxiliary Contact Configuration

1 NC

Terminal Type

Screw

Contactor Application

Motor Control

Control Circuit Voltage Uc

24 V dc

Minimum Operating Temperature

-25°C

Operational Current Ie

7A

Maximum Operating Temperature

60°C

Standards/Approvals

EN 60947

Length

68mm

Depth

75mm

Width

45 mm

Pole and Throw Configuration

3

Eaton Contactor, Screw Terminal Type, 0.1W Minimal Heat Dissipation Per Pole - DILM Series - 276565 DILM7-10(24VDC)


Power your electric circuit on or off using this contactor from Eaton. It works by emitting a magnetic field when the internal coil receives energy. This causes the contacts to open or close, turning the circuit on or off. The screw terminal design lets you tighten your wires to ensure a secure electrical connection in essential devices like HVAC equipment and lighting fixtures. As the unit's mounting position is adjustable, you have a free hand when installing it in your panel.

Features & Benefits


• Mechanical service life of 20 million cycles for long-lasting use

• Finger-proof and back-of-hand-proof, so users are protected from electric shocks

• Minimal heat dissipation per pole of 0.1W for energy-efficient performance

• Resists mechanical shock of up to 10g for safe use in challenging operating conditions

How often can I use this contactor?


As it handles up to 5000 operations an hour, you can safely use this contactor with equipment that repeatedly stops and starts.

What switching time will I get from this contactor?


As it's DC-operated, this speedy contactor has a closing delay of 31ms and an opening delay of 12ms for rapid power switching.

Note

Eaton formerly known as Moeller