- RS Stock No.:
- 608-9649
- Mfr. Part No.:
- LC1D32M7
- Manufacturer:
- Schneider Electric
12 In Global stock for delivery. NCR Plus within 10 working day(s), rest of PH within 14 working days
10 In Global stock for delivery. NCR Plus within 10 working day(s), rest of PH within 14 working days
Added
Price Each
Was PHP13,480.10
You pay
PHP12,806.10
(exc. VAT)
PHP14,342.83
(inc. VAT)
Units | Per Unit |
1 - 4 | PHP12,806.10 |
5 - 9 | PHP10,244.88 |
10 + | PHP9,604.58 |
- RS Stock No.:
- 608-9649
- Mfr. Part No.:
- LC1D32M7
- Manufacturer:
- Schneider Electric
Legislation and Compliance
Product Details
Schneider Electric LC1D TeSys D Contactors
TeSys D Contactors from Schneider Electric combine long mechanical and electrical life to offer a high reliable contactor. The range has been designed for integration in control systems and can be used to create motor starters for any type of application. The TeSys D contactors offer quick simple setup while maintaining compliance with international standards.
Features and Benefits
Built-in auxiliary contacts for added switching capability
Screw connections: IP20 finger-safe terminals with both North American and International terminal markings
Can be panel mounted with screws or DIN Rail mounted
Bidirectional peak limiting diode suppressor to protect the coil
Easily installed accessories
Flexible control circuit to suit a wide range of applications
Screw connections: IP20 finger-safe terminals with both North American and International terminal markings
Can be panel mounted with screws or DIN Rail mounted
Bidirectional peak limiting diode suppressor to protect the coil
Easily installed accessories
Flexible control circuit to suit a wide range of applications
What does the utilisation category AC1 and AC3 mean for the TeSys contactors?
Contactor utilisation categories define the current making and breaking values, based on the type of load to be controlled and the operating cycle conditions.
- AC-1: This applies to all AC devices with a power factor of at least 0.95. Example of use: resistive load, heating, distribution.
- AC-3: This applies to squirrel cage motors where breaking occurs while the motor is running. Example of use: all squirrel cage motors, lifts, escalators, conveyors, bucket elevators, compressors, pumps, mixers, air conditioning units.
What accessories are available?
Auxiliary contact blocks with serrated wiping action
Front mount dust tight auxiliary contact blocks
Pneumatic time delay blocks
Transient voltage surge suppressors
Interface modules and electronic timers
Mechanical latching blocks
Front mount dust tight auxiliary contact blocks
Pneumatic time delay blocks
Transient voltage surge suppressors
Interface modules and electronic timers
Mechanical latching blocks
Is the TeSys D range a double break pole type contactor?
Yes the Tesys D range uses linear translation movement that provides double breaking of the poles.
Schneider Electric LC1D32M7 Contactor
The Schneider Electric LC1D32M7 model is a 3 pole contactor featuring a 220 V ac operating coil, with an AC-3 full load current rating of 32 A.
Features & Benefits
• 3 pole contactor for versatile applications
• Screw terminal type for easy and secure connections
• Wide operating temperature range from 5°C to +60°C
• AC 3 utilisation category for efficient power circuit operation
• Compact design with dimensions of 85mm x 45mm x 90mm
• High contacts voltage rating of 690V AC for enhanced safety
• Screw terminal type for easy and secure connections
• Wide operating temperature range from 5°C to +60°C
• AC 3 utilisation category for efficient power circuit operation
• Compact design with dimensions of 85mm x 45mm x 90mm
• High contacts voltage rating of 690V AC for enhanced safety
Applications
• Ideal for motor control in industrial machinery
• Suitable for use in HVAC systems for reliable operation
• Perfect for lighting control applications in commercial buildings
• Can be used in pumps, fans, and compressors for efficient operation
• Suitable for use in HVAC systems for reliable operation
• Perfect for lighting control applications in commercial buildings
• Can be used in pumps, fans, and compressors for efficient operation
Can it handle high power ratings?
The Schneider Electric contactor is designed to handle power ratings up to 15kW, making it suitable for a wide range of applications.
Will it ensure safe and reliable operation?
Yes, the contactor features a high contact voltage rating of 690V AC and is designed to provide safe and reliable performance in various environments.
Can it be used in harsh operating conditions?
The contactor is built to withstand temperatures ranging from -5°C to +60°C, making it suitable for use in a variety of harsh operating conditions.
Specifications
Attribute | Value |
---|---|
Coil Voltage | 230 V ac |
Number of Poles | 3 |
Contact Voltage Rating | 690 V ac |
Contact Current Rating | 32 A |
Range | TeSys D |
Power Rating | 15 kW |
Series | LC1D |
Function | 3-Phase Motor Monitoring |
Normal State Configuration | 3NO |
Auxiliary Contact Configuration | 1NO + 1NC |
Number Of Auxiliary Contacts | 2 |
Terminal Type | Screw |
Length | 85mm |
Width | 45mm |
Depth | 90mm |
Better World Product | Yes |
Better World Verification | Green Premium |
Minimum Operating Temperature | -5°C |
Pole and Throw Configuration | 3P |
Mounting Style | DIN Rail |
Maximum Operating Temperature | +60°C |